H. Min, Boyoung Han, Changmin Sung, K. Lee, H. Kim, Ki Hun Kim, J. Son, Jaeick Lee
{"title":"LC-MS/MS同时分析人尿中生长激素释放肽和分泌物的方法","authors":"H. Min, Boyoung Han, Changmin Sung, K. Lee, H. Kim, Ki Hun Kim, J. Son, Jaeick Lee","doi":"10.5478/MSL.2016.7.3.55","DOIUrl":null,"url":null,"abstract":"Growth hormone (GH)-releasing peptides (GHRPs) and GH secretagogues (GHSs) are listed in the World Anti-Doping Agency (WADA) Prohibited List. In the present study, we developed and validated a method for the simultaneous analysis of seven GHRPs (alexamorelin, GHRP-1, -2, -4, -5, -6, and hexarelin) and three GHSs (anamorelin, ibutamoren, and ipamorelin) in human urine. Method validation was performed at minimum required performance levels specified by WADA technical documents (2 ng/mL) for all substances, and the method was validated with regard to selectivity (no interference), linearity (R2 > 0.9986), matrix effects (50.0%-141.2%), recovery (10.4%-100.8%), and intra- (2.8%-16.5%) and inter-day (7.0%-22.6%) precisions. The limits of detection for screening and confirmation were 0.05-0.5 ng/mL and 0.05-1 ng/mL, respectively.","PeriodicalId":18238,"journal":{"name":"Mass Spectrometry Letters","volume":"58 1","pages":"55-63"},"PeriodicalIF":0.4000,"publicationDate":"2016-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"LC-MS/MS Method for Simultaneous Analysis of Growth Hormone-Releasing Peptides and Secretagogues in Human Urine\",\"authors\":\"H. Min, Boyoung Han, Changmin Sung, K. Lee, H. Kim, Ki Hun Kim, J. Son, Jaeick Lee\",\"doi\":\"10.5478/MSL.2016.7.3.55\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Growth hormone (GH)-releasing peptides (GHRPs) and GH secretagogues (GHSs) are listed in the World Anti-Doping Agency (WADA) Prohibited List. In the present study, we developed and validated a method for the simultaneous analysis of seven GHRPs (alexamorelin, GHRP-1, -2, -4, -5, -6, and hexarelin) and three GHSs (anamorelin, ibutamoren, and ipamorelin) in human urine. Method validation was performed at minimum required performance levels specified by WADA technical documents (2 ng/mL) for all substances, and the method was validated with regard to selectivity (no interference), linearity (R2 > 0.9986), matrix effects (50.0%-141.2%), recovery (10.4%-100.8%), and intra- (2.8%-16.5%) and inter-day (7.0%-22.6%) precisions. The limits of detection for screening and confirmation were 0.05-0.5 ng/mL and 0.05-1 ng/mL, respectively.\",\"PeriodicalId\":18238,\"journal\":{\"name\":\"Mass Spectrometry Letters\",\"volume\":\"58 1\",\"pages\":\"55-63\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2016-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mass Spectrometry Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5478/MSL.2016.7.3.55\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass Spectrometry Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5478/MSL.2016.7.3.55","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
LC-MS/MS Method for Simultaneous Analysis of Growth Hormone-Releasing Peptides and Secretagogues in Human Urine
Growth hormone (GH)-releasing peptides (GHRPs) and GH secretagogues (GHSs) are listed in the World Anti-Doping Agency (WADA) Prohibited List. In the present study, we developed and validated a method for the simultaneous analysis of seven GHRPs (alexamorelin, GHRP-1, -2, -4, -5, -6, and hexarelin) and three GHSs (anamorelin, ibutamoren, and ipamorelin) in human urine. Method validation was performed at minimum required performance levels specified by WADA technical documents (2 ng/mL) for all substances, and the method was validated with regard to selectivity (no interference), linearity (R2 > 0.9986), matrix effects (50.0%-141.2%), recovery (10.4%-100.8%), and intra- (2.8%-16.5%) and inter-day (7.0%-22.6%) precisions. The limits of detection for screening and confirmation were 0.05-0.5 ng/mL and 0.05-1 ng/mL, respectively.