通过 activPAL 和 Actiwatch 对自由生活的青少年和成年人的在床时间进行估算的一致性。

Paul R Hibbing, Jordan A Carlson, Stacey L Simon, Edward L Melanson, Seth A Creasy
{"title":"通过 activPAL 和 Actiwatch 对自由生活的青少年和成年人的在床时间进行估算的一致性。","authors":"Paul R Hibbing, Jordan A Carlson, Stacey L Simon, Edward L Melanson, Seth A Creasy","doi":"10.1123/jmpb.2023-0011","DOIUrl":null,"url":null,"abstract":"<p><p>Actiwatch devices are often used to estimate time in bed (TIB), but recently became commercially unavailable. Thigh-worn activPAL devices could be a viable alternative. We tested convergent validity between activPAL (CREA algorithm) and Actiwatch devices. Data were from free-living samples comprising 47 youth (3-16 valid nights/participant) and 42 adults (6-26 valid nights/participant) who wore both devices concurrently. On average, activPAL predicted earlier bedtimes and later risetimes compared to Actiwatch, resulting in longer overnight intervals (by 1.49 hours/night for youth and 0.67 hours/night for adults; both p < 0.001). TIB interruptions were predicted less commonly by activPAL (mean < 2 interruptions/night for both youth and adults) than Actiwatch (mean of 24-26 interruptions/night in both groups; both p < 0.001). Overnight intervals for both devices tended to overlap for lengthy periods (mean of 7.38 hours/night for youth and 7.69 hours/night for adults). Within these overlapping periods, the devices gave matching epoch-level TIB predictions an average of 87.9% of the time for youth and 84.3% of the time for adults. Most remaining epochs (11.8% and 15.1%, respectively) were classified as TIB by activPAL but not Actiwatch. Overall, the devices had fair agreement during the overlapping periods, but limited agreement when predicting interruptions, bedtime, or risetime. Future work should assess the criterion validity of activPAL devices to understand implications for health research. The present findings demonstrate that activPAL is not interchangeable with Actiwatch, which is consistent with their differing foundations (thigh inclination for activPAL versus wrist movement for Actiwatch).</p>","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11257610/pdf/","citationCount":"0","resultStr":"{\"title\":\"Convergent validity of time in bed estimates from activPAL and Actiwatch in free-living youth and adults.\",\"authors\":\"Paul R Hibbing, Jordan A Carlson, Stacey L Simon, Edward L Melanson, Seth A Creasy\",\"doi\":\"10.1123/jmpb.2023-0011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Actiwatch devices are often used to estimate time in bed (TIB), but recently became commercially unavailable. Thigh-worn activPAL devices could be a viable alternative. We tested convergent validity between activPAL (CREA algorithm) and Actiwatch devices. Data were from free-living samples comprising 47 youth (3-16 valid nights/participant) and 42 adults (6-26 valid nights/participant) who wore both devices concurrently. On average, activPAL predicted earlier bedtimes and later risetimes compared to Actiwatch, resulting in longer overnight intervals (by 1.49 hours/night for youth and 0.67 hours/night for adults; both p < 0.001). TIB interruptions were predicted less commonly by activPAL (mean < 2 interruptions/night for both youth and adults) than Actiwatch (mean of 24-26 interruptions/night in both groups; both p < 0.001). Overnight intervals for both devices tended to overlap for lengthy periods (mean of 7.38 hours/night for youth and 7.69 hours/night for adults). Within these overlapping periods, the devices gave matching epoch-level TIB predictions an average of 87.9% of the time for youth and 84.3% of the time for adults. Most remaining epochs (11.8% and 15.1%, respectively) were classified as TIB by activPAL but not Actiwatch. Overall, the devices had fair agreement during the overlapping periods, but limited agreement when predicting interruptions, bedtime, or risetime. Future work should assess the criterion validity of activPAL devices to understand implications for health research. The present findings demonstrate that activPAL is not interchangeable with Actiwatch, which is consistent with their differing foundations (thigh inclination for activPAL versus wrist movement for Actiwatch).</p>\",\"PeriodicalId\":73572,\"journal\":{\"name\":\"Journal for the measurement of physical behaviour\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11257610/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal for the measurement of physical behaviour\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1123/jmpb.2023-0011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal for the measurement of physical behaviour","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1123/jmpb.2023-0011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Actiwatch 设备通常用于估算在床时间(TIB),但最近已无法在市场上买到。佩戴在大腿上的 activPAL 设备可能是一种可行的替代方法。我们测试了 activPAL(CREA 算法)和 Actiwatch 设备之间的收敛有效性。数据来自自由生活样本,包括 47 名青少年(3-16 个有效夜晚/参与者)和 42 名成年人(6-26 个有效夜晚/参与者),他们同时佩戴了这两种设备。平均而言,与 Actiwatch 相比,activPAL 预测的就寝时间更早,起床时间更晚,从而延长了过夜间隔(青少年为 1.49 小时/晚,成年人为 0.67 小时/晚;两者的 p 均小于 0.001)。与 Actiwatch 相比,activPAL(青少年和成人的平均中断次数均小于 2 次/夜)预测的 TIB 中断次数较少(两组的平均中断次数均为 24-26 次/夜;两者的 p 均小于 0.001)。两种设备的过夜间隔往往长时间重叠(青少年平均 7.38 小时/夜,成人平均 7.69 小时/夜)。在这些重叠时段内,两种设备平均有 87.9% 的时间对青少年和 84.3% 的时间对成人的 TIB 预测进行了匹配。剩余的大部分时间(分别为 11.8% 和 15.1%)被 activPAL 归类为 TIB,但没有被 Actiwatch 归类。总体而言,这些设备在重叠时段的一致性尚可,但在预测中断、就寝时间或起床时间时的一致性有限。未来的工作应评估 activPAL 设备的标准有效性,以了解其对健康研究的影响。目前的研究结果表明,activPAL 与 Actiwatch 不能互换,这与它们不同的基础(activPAL 的大腿倾斜与 Actiwatch 的手腕运动)是一致的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Convergent validity of time in bed estimates from activPAL and Actiwatch in free-living youth and adults.

Actiwatch devices are often used to estimate time in bed (TIB), but recently became commercially unavailable. Thigh-worn activPAL devices could be a viable alternative. We tested convergent validity between activPAL (CREA algorithm) and Actiwatch devices. Data were from free-living samples comprising 47 youth (3-16 valid nights/participant) and 42 adults (6-26 valid nights/participant) who wore both devices concurrently. On average, activPAL predicted earlier bedtimes and later risetimes compared to Actiwatch, resulting in longer overnight intervals (by 1.49 hours/night for youth and 0.67 hours/night for adults; both p < 0.001). TIB interruptions were predicted less commonly by activPAL (mean < 2 interruptions/night for both youth and adults) than Actiwatch (mean of 24-26 interruptions/night in both groups; both p < 0.001). Overnight intervals for both devices tended to overlap for lengthy periods (mean of 7.38 hours/night for youth and 7.69 hours/night for adults). Within these overlapping periods, the devices gave matching epoch-level TIB predictions an average of 87.9% of the time for youth and 84.3% of the time for adults. Most remaining epochs (11.8% and 15.1%, respectively) were classified as TIB by activPAL but not Actiwatch. Overall, the devices had fair agreement during the overlapping periods, but limited agreement when predicting interruptions, bedtime, or risetime. Future work should assess the criterion validity of activPAL devices to understand implications for health research. The present findings demonstrate that activPAL is not interchangeable with Actiwatch, which is consistent with their differing foundations (thigh inclination for activPAL versus wrist movement for Actiwatch).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信