用于高性能X射线探测器的Cs3Bi2I9单晶掺杂改性

Anfeng Li, Manman Yang, Aoxi He, Peng Tang, X. Hao, Lili Wu, Wenbo Tian, Dingyu Yang, Jingquan Zhang
{"title":"用于高性能X射线探测器的Cs3Bi2I9单晶掺杂改性","authors":"Anfeng Li, Manman Yang, Aoxi He, Peng Tang, X. Hao, Lili Wu, Wenbo Tian, Dingyu Yang, Jingquan Zhang","doi":"10.1002/pssr.202300306","DOIUrl":null,"url":null,"abstract":"Cs3Bi2I9 (CBI) is a promising material for direct X‐ray detectors. However, for the solution method, due to the difference in the chemical potential of Cs+, Bi3+, ​​I‐ ions in the solvent, the composition of Cs3Bi2I9 single crystals (SC) prepared by the solution method often deviates from the stoichiometric ratio, resulting in the formation of many defects in the material, which degrades the quality of the SC. In this work, Br‐ and Cl‐ were used as dopants to produce CBI SCs by the top seed solution method. It can be speculated that the dopant ions could reduce the VI defects in the CBI by means of density functional theory (DFT) calculations. The carrier lifetimes of CBI SCs doped with Br‐ and Cl‐ have been increased to 41.7 ns and 13.0 ns, respectively. Meanwhile, the defect densities of the SCs were reduced to 1.02×109 cm‐3 and 1.85×109 cm‐3, respectively. X‐ray detectors based on Br‐doped CBI and Cl‐doped CBI SCs exhibited high X‐ray sensitivity of 23071.3 μC Gyair\n‐1cm‐2 and 18525.3 μC Gyair\n‐1cm‐2 at an electric field of 40 V mm‐1, respectively. In addition, the X‐ray detection limit reaches 1.07 nGyairs‐1 and 1.35 nGyairs‐1 at an electric field of 2.5 V mm‐1, respectively.This article is protected by copyright. All rights reserved.","PeriodicalId":20059,"journal":{"name":"physica status solidi (RRL) – Rapid Research Letters","volume":"41 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Doping modification of Cs3Bi2I9 single crystals for high performance X‐ray detectors\",\"authors\":\"Anfeng Li, Manman Yang, Aoxi He, Peng Tang, X. Hao, Lili Wu, Wenbo Tian, Dingyu Yang, Jingquan Zhang\",\"doi\":\"10.1002/pssr.202300306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cs3Bi2I9 (CBI) is a promising material for direct X‐ray detectors. However, for the solution method, due to the difference in the chemical potential of Cs+, Bi3+, ​​I‐ ions in the solvent, the composition of Cs3Bi2I9 single crystals (SC) prepared by the solution method often deviates from the stoichiometric ratio, resulting in the formation of many defects in the material, which degrades the quality of the SC. In this work, Br‐ and Cl‐ were used as dopants to produce CBI SCs by the top seed solution method. It can be speculated that the dopant ions could reduce the VI defects in the CBI by means of density functional theory (DFT) calculations. The carrier lifetimes of CBI SCs doped with Br‐ and Cl‐ have been increased to 41.7 ns and 13.0 ns, respectively. Meanwhile, the defect densities of the SCs were reduced to 1.02×109 cm‐3 and 1.85×109 cm‐3, respectively. X‐ray detectors based on Br‐doped CBI and Cl‐doped CBI SCs exhibited high X‐ray sensitivity of 23071.3 μC Gyair\\n‐1cm‐2 and 18525.3 μC Gyair\\n‐1cm‐2 at an electric field of 40 V mm‐1, respectively. In addition, the X‐ray detection limit reaches 1.07 nGyairs‐1 and 1.35 nGyairs‐1 at an electric field of 2.5 V mm‐1, respectively.This article is protected by copyright. All rights reserved.\",\"PeriodicalId\":20059,\"journal\":{\"name\":\"physica status solidi (RRL) – Rapid Research Letters\",\"volume\":\"41 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"physica status solidi (RRL) – Rapid Research Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/pssr.202300306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"physica status solidi (RRL) – Rapid Research Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/pssr.202300306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Cs3Bi2I9 (CBI)是一种很有前途的X射线直接探测器材料。然而,溶液法制备的Cs3Bi2I9单晶(SC)由于溶剂中Cs+、Bi3+、I‐离子的化学势不同,其组成往往偏离化学计量比,导致材料中形成许多缺陷,从而降低了SC的质量。本研究以Br‐和Cl‐为掺杂剂,采用top seed溶液法制备了CBI SC。通过密度泛函理论(DFT)计算可以推测,掺杂离子可以减少CBI中的VI缺陷。掺入Br‐和Cl‐的CBI SCs的载流子寿命分别提高到41.7 ns和13.0 ns。同时,sc的缺陷密度分别降至1.02×109 cm‐3和1.85×109 cm‐3。基于Br掺杂CBI和Cl掺杂CBI sc的X射线探测器在40 V mm‐1电场下分别表现出23071.3 μC Gyair‐1cm‐2和18525.3 μC Gyair‐1cm‐2的高X射线灵敏度。此外,在2.5 V mm‐1电场下,X射线检测极限分别达到1.07和1.35 nGyairs‐1。这篇文章受版权保护。版权所有。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Doping modification of Cs3Bi2I9 single crystals for high performance X‐ray detectors
Cs3Bi2I9 (CBI) is a promising material for direct X‐ray detectors. However, for the solution method, due to the difference in the chemical potential of Cs+, Bi3+, ​​I‐ ions in the solvent, the composition of Cs3Bi2I9 single crystals (SC) prepared by the solution method often deviates from the stoichiometric ratio, resulting in the formation of many defects in the material, which degrades the quality of the SC. In this work, Br‐ and Cl‐ were used as dopants to produce CBI SCs by the top seed solution method. It can be speculated that the dopant ions could reduce the VI defects in the CBI by means of density functional theory (DFT) calculations. The carrier lifetimes of CBI SCs doped with Br‐ and Cl‐ have been increased to 41.7 ns and 13.0 ns, respectively. Meanwhile, the defect densities of the SCs were reduced to 1.02×109 cm‐3 and 1.85×109 cm‐3, respectively. X‐ray detectors based on Br‐doped CBI and Cl‐doped CBI SCs exhibited high X‐ray sensitivity of 23071.3 μC Gyair ‐1cm‐2 and 18525.3 μC Gyair ‐1cm‐2 at an electric field of 40 V mm‐1, respectively. In addition, the X‐ray detection limit reaches 1.07 nGyairs‐1 and 1.35 nGyairs‐1 at an electric field of 2.5 V mm‐1, respectively.This article is protected by copyright. All rights reserved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信