集成SU-8微毛细抽芯结构的液-气相变膜驱动器的表征与建模

S. Whalen, S. Won, R. Richards, D. Bahr, C. Richards
{"title":"集成SU-8微毛细抽芯结构的液-气相变膜驱动器的表征与建模","authors":"S. Whalen, S. Won, R. Richards, D. Bahr, C. Richards","doi":"10.1109/SENSOR.2005.1496426","DOIUrl":null,"url":null,"abstract":"A liquid-vapor phase-change membrane actuator is demonstrated which integrates an open groove wicking structure to continuously pump liquid into the heat addition region of the pressure cavity. Integration of the wick yields a higher efficiency and operating speed compared with existing thermal phase-change actuators. This improvement results from control of the liquid thickness, volume, and fill rate. An experimentally validated numerical model is presented which determines the energy budget within the actuator and investigates factors controlling efficiency such as wick thickness, thermal mass, thermal conductivity, and membrane compliance. Work to date for this class of actuators has focused primarily on steady state behavior with detailed transient analyses receiving little attention. This investigation focuses strictly on characterization of transient operation and provides a benchmark for this class of dynamic thermal actuators. The actuator presented in this work develops pressure and deflection excursions of 148 kPa and 70 /spl mu/m at 10 Hz while consuming 150 mW. A peak force of 1.4 N is generated during each cycle and the thermal to mechanical efficiency is 0.11%.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"81 1","pages":"342-347 Vol. 1"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Characterization and modeling of a liquid-vapor phase change membrane actuator with an integrated SU-8 micro capillary wicking structure\",\"authors\":\"S. Whalen, S. Won, R. Richards, D. Bahr, C. Richards\",\"doi\":\"10.1109/SENSOR.2005.1496426\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A liquid-vapor phase-change membrane actuator is demonstrated which integrates an open groove wicking structure to continuously pump liquid into the heat addition region of the pressure cavity. Integration of the wick yields a higher efficiency and operating speed compared with existing thermal phase-change actuators. This improvement results from control of the liquid thickness, volume, and fill rate. An experimentally validated numerical model is presented which determines the energy budget within the actuator and investigates factors controlling efficiency such as wick thickness, thermal mass, thermal conductivity, and membrane compliance. Work to date for this class of actuators has focused primarily on steady state behavior with detailed transient analyses receiving little attention. This investigation focuses strictly on characterization of transient operation and provides a benchmark for this class of dynamic thermal actuators. The actuator presented in this work develops pressure and deflection excursions of 148 kPa and 70 /spl mu/m at 10 Hz while consuming 150 mW. A peak force of 1.4 N is generated during each cycle and the thermal to mechanical efficiency is 0.11%.\",\"PeriodicalId\":22359,\"journal\":{\"name\":\"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.\",\"volume\":\"81 1\",\"pages\":\"342-347 Vol. 1\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2005.1496426\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2005.1496426","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

介绍了一种采用开槽抽芯结构的液-气相变膜致动器,将液体连续泵入压力腔的加热区。与现有的热相变执行器相比,灯芯的集成产生了更高的效率和运行速度。这种改进来自于对液体厚度、体积和填充率的控制。提出了一个实验验证的数值模型,该模型确定了执行器内的能量预算,并研究了控制效率的因素,如灯芯厚度、热质量、导热系数和膜柔度。迄今为止,这类执行器的工作主要集中在稳态行为上,而详细的瞬态分析很少受到关注。本研究着重于瞬态运行的特性,并为这类动态热致动器提供了一个基准。本工作中提出的执行器在10 Hz下产生148 kPa和70 /spl mu/m的压力和偏转偏移,同时消耗150 mW。每次循环产生的峰值力为1.4 N,热机械效率为0.11%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characterization and modeling of a liquid-vapor phase change membrane actuator with an integrated SU-8 micro capillary wicking structure
A liquid-vapor phase-change membrane actuator is demonstrated which integrates an open groove wicking structure to continuously pump liquid into the heat addition region of the pressure cavity. Integration of the wick yields a higher efficiency and operating speed compared with existing thermal phase-change actuators. This improvement results from control of the liquid thickness, volume, and fill rate. An experimentally validated numerical model is presented which determines the energy budget within the actuator and investigates factors controlling efficiency such as wick thickness, thermal mass, thermal conductivity, and membrane compliance. Work to date for this class of actuators has focused primarily on steady state behavior with detailed transient analyses receiving little attention. This investigation focuses strictly on characterization of transient operation and provides a benchmark for this class of dynamic thermal actuators. The actuator presented in this work develops pressure and deflection excursions of 148 kPa and 70 /spl mu/m at 10 Hz while consuming 150 mW. A peak force of 1.4 N is generated during each cycle and the thermal to mechanical efficiency is 0.11%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信