里贝朗普雷图玄武岩 (BRP-1) 的 ID-TIMS Sm-Nd 和 Sr 同位素比率

IF 2.7 2区 地球科学 Q2 GEOCHEMISTRY & GEOPHYSICS
Carla Neto, Claudio de Morisson Valeriano, Jacinta Enzweiler, Gabriel Paravidini, Manuela Carvalho, Monica Heilbron, Cristiano Lana, João Henrique Larizzatti
{"title":"里贝朗普雷图玄武岩 (BRP-1) 的 ID-TIMS Sm-Nd 和 Sr 同位素比率","authors":"Carla Neto,&nbsp;Claudio de Morisson Valeriano,&nbsp;Jacinta Enzweiler,&nbsp;Gabriel Paravidini,&nbsp;Manuela Carvalho,&nbsp;Monica Heilbron,&nbsp;Cristiano Lana,&nbsp;João Henrique Larizzatti","doi":"10.1111/ggr.12498","DOIUrl":null,"url":null,"abstract":"<p>This work presents Sm-Nd and Sr isotopic ratios of the BRP-1 (“Basalt Ribeirão Preto”) reference material (RM) based on repeated TIMS measurements over twelve years carried out by the LAGIR laboratory, Brazil. The BRP-1 RM was produced by the Brazilian Geological Survey from a <i>ca</i>. 130 Ma within-plate basalt, collected from a quarry near Ribeirão Preto city in the Paraná basin. Isotope ratios were measured using a TRITON mass spectrometer. Instrumental bias and fractionation corrections were performed based on repeated measurements of the certified RMs JNdi-1 and NIST SRM 987. The measured Nd and Sr isotopic ratios of BRP-1 are: <sup>143</sup>Nd/<sup>144</sup>Nd = 0.512408 ± 0.000010 (2<i>s</i>), and <sup>87</sup>Sr/<sup>86</sup>Sr = 0.706011 ± 0.000017 (2<i>s</i>). The mass fractions of Sm and Nd are 11.0 ± 0.2 and 51.9 ± 0.6 μg g<sup>-1</sup>, respectively, showing no significant differences compared with the accepted values from the literature. No significant difference between measurements was observed, whether digesting samples in single or batch mode, using metal-jacketed PTFE bombs or PFA vials, or with or without the addition of a spike. The accuracy of these results was evaluated through the measurement of well-characterised USGS RMs, such as AGV-1, BCR-1, BHVO-1, G-2 and GSP-1.</p>","PeriodicalId":12631,"journal":{"name":"Geostandards and Geoanalytical Research","volume":"47 4","pages":"841-854"},"PeriodicalIF":2.7000,"publicationDate":"2023-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"ID-TIMS Sm-Nd and Sr Isotope Ratios of Reference Material Basalt Ribeirão Preto (BRP-1)\",\"authors\":\"Carla Neto,&nbsp;Claudio de Morisson Valeriano,&nbsp;Jacinta Enzweiler,&nbsp;Gabriel Paravidini,&nbsp;Manuela Carvalho,&nbsp;Monica Heilbron,&nbsp;Cristiano Lana,&nbsp;João Henrique Larizzatti\",\"doi\":\"10.1111/ggr.12498\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This work presents Sm-Nd and Sr isotopic ratios of the BRP-1 (“Basalt Ribeirão Preto”) reference material (RM) based on repeated TIMS measurements over twelve years carried out by the LAGIR laboratory, Brazil. The BRP-1 RM was produced by the Brazilian Geological Survey from a <i>ca</i>. 130 Ma within-plate basalt, collected from a quarry near Ribeirão Preto city in the Paraná basin. Isotope ratios were measured using a TRITON mass spectrometer. Instrumental bias and fractionation corrections were performed based on repeated measurements of the certified RMs JNdi-1 and NIST SRM 987. The measured Nd and Sr isotopic ratios of BRP-1 are: <sup>143</sup>Nd/<sup>144</sup>Nd = 0.512408 ± 0.000010 (2<i>s</i>), and <sup>87</sup>Sr/<sup>86</sup>Sr = 0.706011 ± 0.000017 (2<i>s</i>). The mass fractions of Sm and Nd are 11.0 ± 0.2 and 51.9 ± 0.6 μg g<sup>-1</sup>, respectively, showing no significant differences compared with the accepted values from the literature. No significant difference between measurements was observed, whether digesting samples in single or batch mode, using metal-jacketed PTFE bombs or PFA vials, or with or without the addition of a spike. The accuracy of these results was evaluated through the measurement of well-characterised USGS RMs, such as AGV-1, BCR-1, BHVO-1, G-2 and GSP-1.</p>\",\"PeriodicalId\":12631,\"journal\":{\"name\":\"Geostandards and Geoanalytical Research\",\"volume\":\"47 4\",\"pages\":\"841-854\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Geostandards and Geoanalytical Research\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/ggr.12498\",\"RegionNum\":2,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GEOCHEMISTRY & GEOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geostandards and Geoanalytical Research","FirstCategoryId":"89","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ggr.12498","RegionNum":2,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
引用次数: 1

摘要

本文基于巴西LAGIR实验室在12年的时间里进行的重复TIMS测量,介绍了BRP-1(“玄武岩ribeir o Preto”)参考物质(RM)的Sm-Nd和Sr同位素比率。BRP-1 RM是由巴西地质调查局从帕拉paran盆地ribebe o Preto市附近的采石场采集的约130 Ma的板内玄武岩中提取的。同位素比值用TRITON质谱仪测量。通过重复测量经认证的均方根JNdi-1和NIST SRM 987,进行仪器偏差和分馏校正。BRP-1的Nd、Sr同位素比值分别为:143Nd/144Nd = 0.512408±0.000010 (2s), 87Sr/86Sr = 0.706011±0.000017 (2s)。Sm和Nd的质量分数分别为11.0±0.2和51.9±0.6 μg -1,与文献中接受的值相比无显著差异。无论是在单个或批量模式下消化样品,使用金属护套PTFE弹或PFA小瓶,还是添加或不添加尖峰,测量结果之间没有显着差异。通过测量特征良好的USGS均方根值(如AGV-1、BCR-1、BHVO-1、G-2和GSP-1)来评估这些结果的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

ID-TIMS Sm-Nd and Sr Isotope Ratios of Reference Material Basalt Ribeirão Preto (BRP-1)

ID-TIMS Sm-Nd and Sr Isotope Ratios of Reference Material Basalt Ribeirão Preto (BRP-1)

ID-TIMS Sm-Nd and Sr Isotope Ratios of Reference Material Basalt Ribeirão Preto (BRP-1)

This work presents Sm-Nd and Sr isotopic ratios of the BRP-1 (“Basalt Ribeirão Preto”) reference material (RM) based on repeated TIMS measurements over twelve years carried out by the LAGIR laboratory, Brazil. The BRP-1 RM was produced by the Brazilian Geological Survey from a ca. 130 Ma within-plate basalt, collected from a quarry near Ribeirão Preto city in the Paraná basin. Isotope ratios were measured using a TRITON mass spectrometer. Instrumental bias and fractionation corrections were performed based on repeated measurements of the certified RMs JNdi-1 and NIST SRM 987. The measured Nd and Sr isotopic ratios of BRP-1 are: 143Nd/144Nd = 0.512408 ± 0.000010 (2s), and 87Sr/86Sr = 0.706011 ± 0.000017 (2s). The mass fractions of Sm and Nd are 11.0 ± 0.2 and 51.9 ± 0.6 μg g-1, respectively, showing no significant differences compared with the accepted values from the literature. No significant difference between measurements was observed, whether digesting samples in single or batch mode, using metal-jacketed PTFE bombs or PFA vials, or with or without the addition of a spike. The accuracy of these results was evaluated through the measurement of well-characterised USGS RMs, such as AGV-1, BCR-1, BHVO-1, G-2 and GSP-1.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Geostandards and Geoanalytical Research
Geostandards and Geoanalytical Research 地学-地球科学综合
CiteScore
7.10
自引率
18.40%
发文量
54
审稿时长
>12 weeks
期刊介绍: Geostandards & Geoanalytical Research is an international journal dedicated to advancing the science of reference materials, analytical techniques and data quality relevant to the chemical analysis of geological and environmental samples. Papers are accepted for publication following peer review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信