{"title":"反相高效液相色谱法同时测定盐酸地苯氧酸原料药中二苯氧酸、腈酰胺和溴二苯丁腈的方法建立与验证","authors":"R.S.Lokh, P.U.Singare, P. Jadhav","doi":"10.5923/j.fs.20120202.01","DOIUrl":null,"url":null,"abstract":"Related substances by HPLC method was developed and validated for Diphenoxylate hydrochloride bulk drug and its three potential impurities i.e. Diphenoxylic acid (degradation product), Nitrile amide (precursor) and Bromo Diphenyl butro nitrile (precursor). Analysis was performed on AGILENT 1100 SERIES HPLC system with auto injector and binary gradient high pressure mixing pump on Inersil ODS-3 (RP C 18) column. Mobile phase of Acetonitrile and HPLC water pH adjusted to 2.3 with orthophosphoric acid in the ratio of 25:75 (v/v) with change in the ratio of mobile phase by linear gradient to 85: 25 (v/v) in 45 minute was pumped at 2mL/min and the detection was done at 210 nm. The parameter for which the method was validated included specificity, limit of detection and quantitation, linearity, precision, accuracy and robustness. The method was successfully used to quantitate the levels known impurities {i.e. Diphenoxylic acid (degradation product), Nitrileamide (precursor) and Bromo Diphenyl butro nitrile (precursor)} and unkown impurities in Diphenoxylate hydro- chloride bulk drug.","PeriodicalId":7823,"journal":{"name":"Analytical chemistry, an Indian journal","volume":"18 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2012-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and validation for reverse phase high performance liquid chromatographic method for simultaneously determination for diphenoxylic acid, nitrileamide and bromdiphenyl butoro nitrile in diphenoxylate hydrochloride bulk drug\",\"authors\":\"R.S.Lokh, P.U.Singare, P. Jadhav\",\"doi\":\"10.5923/j.fs.20120202.01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Related substances by HPLC method was developed and validated for Diphenoxylate hydrochloride bulk drug and its three potential impurities i.e. Diphenoxylic acid (degradation product), Nitrile amide (precursor) and Bromo Diphenyl butro nitrile (precursor). Analysis was performed on AGILENT 1100 SERIES HPLC system with auto injector and binary gradient high pressure mixing pump on Inersil ODS-3 (RP C 18) column. Mobile phase of Acetonitrile and HPLC water pH adjusted to 2.3 with orthophosphoric acid in the ratio of 25:75 (v/v) with change in the ratio of mobile phase by linear gradient to 85: 25 (v/v) in 45 minute was pumped at 2mL/min and the detection was done at 210 nm. The parameter for which the method was validated included specificity, limit of detection and quantitation, linearity, precision, accuracy and robustness. The method was successfully used to quantitate the levels known impurities {i.e. Diphenoxylic acid (degradation product), Nitrileamide (precursor) and Bromo Diphenyl butro nitrile (precursor)} and unkown impurities in Diphenoxylate hydro- chloride bulk drug.\",\"PeriodicalId\":7823,\"journal\":{\"name\":\"Analytical chemistry, an Indian journal\",\"volume\":\"18 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical chemistry, an Indian journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5923/j.fs.20120202.01\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical chemistry, an Indian journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5923/j.fs.20120202.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development and validation for reverse phase high performance liquid chromatographic method for simultaneously determination for diphenoxylic acid, nitrileamide and bromdiphenyl butoro nitrile in diphenoxylate hydrochloride bulk drug
Related substances by HPLC method was developed and validated for Diphenoxylate hydrochloride bulk drug and its three potential impurities i.e. Diphenoxylic acid (degradation product), Nitrile amide (precursor) and Bromo Diphenyl butro nitrile (precursor). Analysis was performed on AGILENT 1100 SERIES HPLC system with auto injector and binary gradient high pressure mixing pump on Inersil ODS-3 (RP C 18) column. Mobile phase of Acetonitrile and HPLC water pH adjusted to 2.3 with orthophosphoric acid in the ratio of 25:75 (v/v) with change in the ratio of mobile phase by linear gradient to 85: 25 (v/v) in 45 minute was pumped at 2mL/min and the detection was done at 210 nm. The parameter for which the method was validated included specificity, limit of detection and quantitation, linearity, precision, accuracy and robustness. The method was successfully used to quantitate the levels known impurities {i.e. Diphenoxylic acid (degradation product), Nitrileamide (precursor) and Bromo Diphenyl butro nitrile (precursor)} and unkown impurities in Diphenoxylate hydro- chloride bulk drug.