证明皮质记录和减少炎症反应使用柔性聚合物神经探针

A. Mercanzini, K. Cheung, D. Buhl, M. Boers, A. Maillard, P. Colin, J. Bensadoun, A. Bertsch, A. Carleton, P. Renaud
{"title":"证明皮质记录和减少炎症反应使用柔性聚合物神经探针","authors":"A. Mercanzini, K. Cheung, D. Buhl, M. Boers, A. Maillard, P. Colin, J. Bensadoun, A. Bertsch, A. Carleton, P. Renaud","doi":"10.1109/MEMSYS.2007.4433162","DOIUrl":null,"url":null,"abstract":"We present the fabrication, characterization, use in cortical recording and histological results of a flexible implantable neural probe. The device is microfabricated in polyimide and platinum, allowing for greater flexibility. It incorporates two layers of platinum electrodes, which greatly reduces the size of neural probes and limits the insertion damage. In recording experiments, acute in-vivo measurements were performed in the mouse cortex. Local field potential, single- and multi-neuron activity were simultaneously recorded. We demonstrate using immunohistochemistry techniques reduced inflammation at the implantation site for microfabricated polyimide neural probes. We therefore show that the major advantage of using polymer probes over silicon probes is the reduced damage due to insertion and probe-brain compliance mismatch.","PeriodicalId":6388,"journal":{"name":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","volume":"39 1","pages":"573-576"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"Demonstration of cortical recording and reduced inflammatory response using flexible polymer neural probes\",\"authors\":\"A. Mercanzini, K. Cheung, D. Buhl, M. Boers, A. Maillard, P. Colin, J. Bensadoun, A. Bertsch, A. Carleton, P. Renaud\",\"doi\":\"10.1109/MEMSYS.2007.4433162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present the fabrication, characterization, use in cortical recording and histological results of a flexible implantable neural probe. The device is microfabricated in polyimide and platinum, allowing for greater flexibility. It incorporates two layers of platinum electrodes, which greatly reduces the size of neural probes and limits the insertion damage. In recording experiments, acute in-vivo measurements were performed in the mouse cortex. Local field potential, single- and multi-neuron activity were simultaneously recorded. We demonstrate using immunohistochemistry techniques reduced inflammation at the implantation site for microfabricated polyimide neural probes. We therefore show that the major advantage of using polymer probes over silicon probes is the reduced damage due to insertion and probe-brain compliance mismatch.\",\"PeriodicalId\":6388,\"journal\":{\"name\":\"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)\",\"volume\":\"39 1\",\"pages\":\"573-576\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMSYS.2007.4433162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2007.4433162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

我们介绍了一种柔性植入式神经探针的制造、表征、在皮层记录中的应用和组织学结果。该装置由聚酰亚胺和铂制成,具有更大的灵活性。它采用了两层铂电极,大大减小了神经探针的尺寸,限制了插入损伤。在记录实验中,在小鼠皮层中进行了急性体内测量。同时记录局部场电位、单神经元和多神经元活动。我们证明使用免疫组织化学技术减少了微制造聚酰亚胺神经探针植入部位的炎症。因此,我们表明,与硅探针相比,使用聚合物探针的主要优势是减少了由于插入和探针-脑顺应性不匹配造成的损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Demonstration of cortical recording and reduced inflammatory response using flexible polymer neural probes
We present the fabrication, characterization, use in cortical recording and histological results of a flexible implantable neural probe. The device is microfabricated in polyimide and platinum, allowing for greater flexibility. It incorporates two layers of platinum electrodes, which greatly reduces the size of neural probes and limits the insertion damage. In recording experiments, acute in-vivo measurements were performed in the mouse cortex. Local field potential, single- and multi-neuron activity were simultaneously recorded. We demonstrate using immunohistochemistry techniques reduced inflammation at the implantation site for microfabricated polyimide neural probes. We therefore show that the major advantage of using polymer probes over silicon probes is the reduced damage due to insertion and probe-brain compliance mismatch.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信