放射状导管插管后压缩敷料与止血腕带的比较

Said Assaf Neto , João Orávio de Freitas Jr. , Sérgio Luis Berti , J. Ribamar Costa Jr. , Jorge Augusto L. Zbeid
{"title":"放射状导管插管后压缩敷料与止血腕带的比较","authors":"Said Assaf Neto ,&nbsp;João Orávio de Freitas Jr. ,&nbsp;Sérgio Luis Berti ,&nbsp;J. Ribamar Costa Jr. ,&nbsp;Jorge Augusto L. Zbeid","doi":"10.1016/j.rbci.2017.01.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Introdução</h3><p>Dispositivos dedicados à compressão do sítio de punção radial adicionam custo ao procedimento e não foram adequadamente comparados aos curativos compressivos. Avaliamos a efetividade e a segurança de ambas as formas de hemostasia em pacientes submetidos à cinecoronariografia e/ou intervenção coronária percutânea na prática diária.</p></div><div><h3>Métodos</h3><p>Estudo prospectivo, multicêntrico e não randomizado, que incluiu pacientes consecutivamente submetidos a procedimentos por via radial. A modalidade de compressão ficou a critério do operador e da disponibilidade das pulseiras hemostáticas. O objetivo primário foi a comparação da patência da artéria radial no sétimo dia pós‐procedimento, aferida por meio do Doppler. Secundariamente, avaliamos a ocorrência de hemorragia/hematoma no sítio de punção durante a compressão, após a retirada do dispositivo e no sétimo dia pós‐procedimento.</p></div><div><h3>Resultados</h3><p>Foram avaliados 528 pacientes, 416 que usaram o curativo compressivo e 112 que usaram a pulseira hemostática. Na fase da retirada do introdutor e logo após sua remoção, notou‐se uma incidência maior de sangramento no grupo curativo compressivo (13,4% vs. 0%; <em>p</em> &lt; 0,001). Todos os sangramentos foram pequenos (tipo I ou II) e não necessitaram medidas adicionais. Aos 7 dias, observou‐se apenas formação de pequenos hematomas no sítio da punção em 7,1% dos casos que utilizaram a pulseira de compressão. Não houve diferença nas taxas de patência da artéria radial (3,8% vs. 7,1%; <em>p</em> = 0,20).</p></div><div><h3>Conclusões</h3><p>O uso de pulseira dedicada à hemostasia da artéria radial não resultou em maiores taxas de patência arterial tardia quando comparada ao curativo compressivo simples.</p></div><div><h3>Background</h3><p>Wristband devices used in the compression of the radial puncture site add cost to the procedure and have not been adequately compared with conventional compressive dressings. This study evaluated the effectiveness and safety of both forms of hemostasis in patients undergoing coronary angiography and/or percutaneous coronary intervention in daily practice.</p></div><div><h3>Methods</h3><p>A prospective, multicenter, nonrandomized study, which included consecutive patients who underwent procedures through radial access. The type of compression was at the interventionist's discretion and the availability of wristband devices. The main objective was to compare the patency of the radial artery on the 7<sup>th</sup> day after the procedure, measured by Doppler. Secondarily, the authors evaluated the occurrence of bleeding/hematoma at the puncture site during compression, after removal of the device and on the 7<sup>th</sup> day after the procedure.</p></div><div><h3>Results</h3><p>This study evaluated 528 patients, 416 using conventional compressive dressings and 112 using wristband devices. When the sheath was removed and soon after its removal, a higher incidence of bleeding in the conventional compressive dressings group was observed (13.4% vs. 0%; <em>p</em> &lt; 0.001). All bleeding events were small (type I or type II) and did not require further actions. At 7 days, there were only small hematomas at the puncture site in 7.1% of cases that used the wristband device. There was no difference in the patency rates of the radial artery (3.8% vs. 7.1%; <em>p</em> = 0.20).</p></div><div><h3>Conclusions</h3><p>The use of wristband devices for radial artery hemostasis did not result in higher rates of late arterial patency when compared to conventional compressive dressings.</p></div>","PeriodicalId":101093,"journal":{"name":"Revista Brasileira de Cardiologia Invasiva","volume":"23 4","pages":"Pages 271-275"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.rbci.2017.01.001","citationCount":"5","resultStr":"{\"title\":\"Comparação do curativo compressivo vs. pulseira hemostática após cateterização por via radial\",\"authors\":\"Said Assaf Neto ,&nbsp;João Orávio de Freitas Jr. ,&nbsp;Sérgio Luis Berti ,&nbsp;J. Ribamar Costa Jr. ,&nbsp;Jorge Augusto L. Zbeid\",\"doi\":\"10.1016/j.rbci.2017.01.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introdução</h3><p>Dispositivos dedicados à compressão do sítio de punção radial adicionam custo ao procedimento e não foram adequadamente comparados aos curativos compressivos. Avaliamos a efetividade e a segurança de ambas as formas de hemostasia em pacientes submetidos à cinecoronariografia e/ou intervenção coronária percutânea na prática diária.</p></div><div><h3>Métodos</h3><p>Estudo prospectivo, multicêntrico e não randomizado, que incluiu pacientes consecutivamente submetidos a procedimentos por via radial. A modalidade de compressão ficou a critério do operador e da disponibilidade das pulseiras hemostáticas. O objetivo primário foi a comparação da patência da artéria radial no sétimo dia pós‐procedimento, aferida por meio do Doppler. Secundariamente, avaliamos a ocorrência de hemorragia/hematoma no sítio de punção durante a compressão, após a retirada do dispositivo e no sétimo dia pós‐procedimento.</p></div><div><h3>Resultados</h3><p>Foram avaliados 528 pacientes, 416 que usaram o curativo compressivo e 112 que usaram a pulseira hemostática. Na fase da retirada do introdutor e logo após sua remoção, notou‐se uma incidência maior de sangramento no grupo curativo compressivo (13,4% vs. 0%; <em>p</em> &lt; 0,001). Todos os sangramentos foram pequenos (tipo I ou II) e não necessitaram medidas adicionais. Aos 7 dias, observou‐se apenas formação de pequenos hematomas no sítio da punção em 7,1% dos casos que utilizaram a pulseira de compressão. Não houve diferença nas taxas de patência da artéria radial (3,8% vs. 7,1%; <em>p</em> = 0,20).</p></div><div><h3>Conclusões</h3><p>O uso de pulseira dedicada à hemostasia da artéria radial não resultou em maiores taxas de patência arterial tardia quando comparada ao curativo compressivo simples.</p></div><div><h3>Background</h3><p>Wristband devices used in the compression of the radial puncture site add cost to the procedure and have not been adequately compared with conventional compressive dressings. This study evaluated the effectiveness and safety of both forms of hemostasis in patients undergoing coronary angiography and/or percutaneous coronary intervention in daily practice.</p></div><div><h3>Methods</h3><p>A prospective, multicenter, nonrandomized study, which included consecutive patients who underwent procedures through radial access. The type of compression was at the interventionist's discretion and the availability of wristband devices. The main objective was to compare the patency of the radial artery on the 7<sup>th</sup> day after the procedure, measured by Doppler. Secondarily, the authors evaluated the occurrence of bleeding/hematoma at the puncture site during compression, after removal of the device and on the 7<sup>th</sup> day after the procedure.</p></div><div><h3>Results</h3><p>This study evaluated 528 patients, 416 using conventional compressive dressings and 112 using wristband devices. When the sheath was removed and soon after its removal, a higher incidence of bleeding in the conventional compressive dressings group was observed (13.4% vs. 0%; <em>p</em> &lt; 0.001). All bleeding events were small (type I or type II) and did not require further actions. At 7 days, there were only small hematomas at the puncture site in 7.1% of cases that used the wristband device. There was no difference in the patency rates of the radial artery (3.8% vs. 7.1%; <em>p</em> = 0.20).</p></div><div><h3>Conclusions</h3><p>The use of wristband devices for radial artery hemostasis did not result in higher rates of late arterial patency when compared to conventional compressive dressings.</p></div>\",\"PeriodicalId\":101093,\"journal\":{\"name\":\"Revista Brasileira de Cardiologia Invasiva\",\"volume\":\"23 4\",\"pages\":\"Pages 271-275\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.rbci.2017.01.001\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira de Cardiologia Invasiva\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0104184316300133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Cardiologia Invasiva","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0104184316300133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

用于径向穿刺部位压缩的设备增加了手术的成本,与压缩敷料相比还不够。我们评估了在日常实践中接受冠状动脉造影和/或经皮冠状动脉介入治疗的患者中两种止血方式的有效性和安全性。方法前瞻性、多中心、非随机研究,包括连续接受放射线手术的患者。压缩方式由操作者和止血腕带的可用性决定。主要目的是比较术后第7天径向动脉的通畅程度,用多普勒法测量。其次,我们评估了穿刺部位出血/血肿的发生情况,在压迫过程中,取出设备后和术后第7天。结果528例患者,416例使用压缩绷带,112例使用止血腕带。在移除引体器阶段和移除后不久,压缩敷料组的出血发生率较高(13.4% vs. 0%)。p <0.001)。所有出血均为轻微出血(I型或II型),不需要采取额外措施。在使用压缩腕带的病例中,7.1%的病例在穿刺部位仅出现小瘀伤。桡动脉通畅率无差异(3.8% vs. 7.1%; 3.8% vs. 7.1%)。p = 0.20)。结论与简单的压缩敷料相比,使用专用腕带止血桡动脉并没有导致更高的延迟动脉通畅率。用于压缩放射状穿刺部位的背带装置增加了手术费用,并没有与传统压缩敷料进行充分的比较。本研究评估了两种止血方法在冠状动脉造影和/或经皮冠状动脉介入治疗患者日常实践中的有效性和安全性。方法:前瞻性、多中心、非随机研究,包括连续接受放射状入路手术的患者。压缩的类型出现在interventionist'的自由裁量权和wristband设备的可用性。它的主要目标是径向的主要动脉的后7天的过程,measured多普勒。其次,作者评估了穿刺部位在受压期间、摘除装置后和手术后第7天出血/瘀伤的发生情况。研究结果评估528例患者,416例使用常规压缩敷料,112例使用腕带器械。在常规压缩敷料组中,在摘除护套后及摘除后不久,出血发生率较高(13.4% vs. 0%;p <0001)。所有流血事件是小(型号或类型(2),不需要进一步的行动。在7天内,7.1%使用腕带装置的病例的穿刺部位只有轻微的擦伤。桡动脉通透率无差异(3.8% vs. 7.1%;p = 0.20)。结论与传统压缩敷料相比,使用腕带装置进行桡动脉止血并没有导致较高的延迟动脉粥样硬化率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparação do curativo compressivo vs. pulseira hemostática após cateterização por via radial

Introdução

Dispositivos dedicados à compressão do sítio de punção radial adicionam custo ao procedimento e não foram adequadamente comparados aos curativos compressivos. Avaliamos a efetividade e a segurança de ambas as formas de hemostasia em pacientes submetidos à cinecoronariografia e/ou intervenção coronária percutânea na prática diária.

Métodos

Estudo prospectivo, multicêntrico e não randomizado, que incluiu pacientes consecutivamente submetidos a procedimentos por via radial. A modalidade de compressão ficou a critério do operador e da disponibilidade das pulseiras hemostáticas. O objetivo primário foi a comparação da patência da artéria radial no sétimo dia pós‐procedimento, aferida por meio do Doppler. Secundariamente, avaliamos a ocorrência de hemorragia/hematoma no sítio de punção durante a compressão, após a retirada do dispositivo e no sétimo dia pós‐procedimento.

Resultados

Foram avaliados 528 pacientes, 416 que usaram o curativo compressivo e 112 que usaram a pulseira hemostática. Na fase da retirada do introdutor e logo após sua remoção, notou‐se uma incidência maior de sangramento no grupo curativo compressivo (13,4% vs. 0%; p < 0,001). Todos os sangramentos foram pequenos (tipo I ou II) e não necessitaram medidas adicionais. Aos 7 dias, observou‐se apenas formação de pequenos hematomas no sítio da punção em 7,1% dos casos que utilizaram a pulseira de compressão. Não houve diferença nas taxas de patência da artéria radial (3,8% vs. 7,1%; p = 0,20).

Conclusões

O uso de pulseira dedicada à hemostasia da artéria radial não resultou em maiores taxas de patência arterial tardia quando comparada ao curativo compressivo simples.

Background

Wristband devices used in the compression of the radial puncture site add cost to the procedure and have not been adequately compared with conventional compressive dressings. This study evaluated the effectiveness and safety of both forms of hemostasis in patients undergoing coronary angiography and/or percutaneous coronary intervention in daily practice.

Methods

A prospective, multicenter, nonrandomized study, which included consecutive patients who underwent procedures through radial access. The type of compression was at the interventionist's discretion and the availability of wristband devices. The main objective was to compare the patency of the radial artery on the 7th day after the procedure, measured by Doppler. Secondarily, the authors evaluated the occurrence of bleeding/hematoma at the puncture site during compression, after removal of the device and on the 7th day after the procedure.

Results

This study evaluated 528 patients, 416 using conventional compressive dressings and 112 using wristband devices. When the sheath was removed and soon after its removal, a higher incidence of bleeding in the conventional compressive dressings group was observed (13.4% vs. 0%; p < 0.001). All bleeding events were small (type I or type II) and did not require further actions. At 7 days, there were only small hematomas at the puncture site in 7.1% of cases that used the wristband device. There was no difference in the patency rates of the radial artery (3.8% vs. 7.1%; p = 0.20).

Conclusions

The use of wristband devices for radial artery hemostasis did not result in higher rates of late arterial patency when compared to conventional compressive dressings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信