使用异步时钟周期减少ATE测试时间

P. Venkataramani, V. Agrawal
{"title":"使用异步时钟周期减少ATE测试时间","authors":"P. Venkataramani, V. Agrawal","doi":"10.1109/TEST.2013.6651931","DOIUrl":null,"url":null,"abstract":"A conventional wafer sort test on an automatic test equipment (ATE) uses a fixed synchronous clock period. Typical test cycles may produce high signal activity and to keep the power dissipation under control, a relatively slow test clock is used. This results in long test times, especially for large scan based circuits. Observing that each test clock cycle may consume different amount of power, we propose an asynchronous clock test methodology to reduce the test time. Smallest customized clock periods for test cycles or sets of cycles are computed based on power and critical path constraints. A theoretical analysis shows that the total energy consumed by the entire test is invariant and the test time depends on the rate it is dissipated during test. An asynchronous clock test dissipates this energy at the maximum allowable rate, while the conventional synchronous clock test dissipates it at a lower average rate. The asynchronous clock test method is first implemented in simulation using several ISCAS'89 benchmark circuits. These results show test time reductions up to 47%. To establish the test programming feasibility of the new methodology the Advantest T2000GS ATE at Auburn University Test Lab was used. Test time reduction of 38% is demonstrated for scan test of a circuit. The paper ends with an investigation showing that for a circuit under test, given its power budget and a test there exists a supply voltage that minimizes the test time. An analysis determines whether the shortest test must use a synchronous or an asynchronous clock.","PeriodicalId":6379,"journal":{"name":"2013 IEEE International Test Conference (ITC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"ATE test time reduction using asynchronous clock period\",\"authors\":\"P. Venkataramani, V. Agrawal\",\"doi\":\"10.1109/TEST.2013.6651931\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A conventional wafer sort test on an automatic test equipment (ATE) uses a fixed synchronous clock period. Typical test cycles may produce high signal activity and to keep the power dissipation under control, a relatively slow test clock is used. This results in long test times, especially for large scan based circuits. Observing that each test clock cycle may consume different amount of power, we propose an asynchronous clock test methodology to reduce the test time. Smallest customized clock periods for test cycles or sets of cycles are computed based on power and critical path constraints. A theoretical analysis shows that the total energy consumed by the entire test is invariant and the test time depends on the rate it is dissipated during test. An asynchronous clock test dissipates this energy at the maximum allowable rate, while the conventional synchronous clock test dissipates it at a lower average rate. The asynchronous clock test method is first implemented in simulation using several ISCAS'89 benchmark circuits. These results show test time reductions up to 47%. To establish the test programming feasibility of the new methodology the Advantest T2000GS ATE at Auburn University Test Lab was used. Test time reduction of 38% is demonstrated for scan test of a circuit. The paper ends with an investigation showing that for a circuit under test, given its power budget and a test there exists a supply voltage that minimizes the test time. An analysis determines whether the shortest test must use a synchronous or an asynchronous clock.\",\"PeriodicalId\":6379,\"journal\":{\"name\":\"2013 IEEE International Test Conference (ITC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Test Conference (ITC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TEST.2013.6651931\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Test Conference (ITC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TEST.2013.6651931","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

在自动测试设备(ATE)上的常规晶圆分选测试使用固定的同步时钟周期。典型的测试周期可能产生高信号活动,为了控制功耗,使用相对较慢的测试时钟。这导致测试时间长,特别是对于基于大型扫描的电路。观察到每个测试时钟周期可能消耗不同数量的功率,我们提出一种异步时钟测试方法来减少测试时间。测试周期或周期集的最小定制时钟周期是基于功率和关键路径约束计算的。理论分析表明,整个试验消耗的总能量是不变的,试验时间取决于试验过程中能量耗散的速率。异步时钟测试以最大允许速率耗散该能量,而常规同步时钟测试以较低的平均速率耗散该能量。异步时钟测试方法首先在多个ISCAS'89基准电路的仿真中实现。这些结果表明测试时间减少了47%。为了确定新方法的测试编程可行性,使用了奥本大学测试实验室的Advantest T2000GS ATE。电路扫描测试的测试时间减少了38%。本文最后的研究表明,对于被测电路,给定其功率预算和测试,存在一个使测试时间最小的电源电压。分析确定最短的测试是否必须使用同步时钟或异步时钟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ATE test time reduction using asynchronous clock period
A conventional wafer sort test on an automatic test equipment (ATE) uses a fixed synchronous clock period. Typical test cycles may produce high signal activity and to keep the power dissipation under control, a relatively slow test clock is used. This results in long test times, especially for large scan based circuits. Observing that each test clock cycle may consume different amount of power, we propose an asynchronous clock test methodology to reduce the test time. Smallest customized clock periods for test cycles or sets of cycles are computed based on power and critical path constraints. A theoretical analysis shows that the total energy consumed by the entire test is invariant and the test time depends on the rate it is dissipated during test. An asynchronous clock test dissipates this energy at the maximum allowable rate, while the conventional synchronous clock test dissipates it at a lower average rate. The asynchronous clock test method is first implemented in simulation using several ISCAS'89 benchmark circuits. These results show test time reductions up to 47%. To establish the test programming feasibility of the new methodology the Advantest T2000GS ATE at Auburn University Test Lab was used. Test time reduction of 38% is demonstrated for scan test of a circuit. The paper ends with an investigation showing that for a circuit under test, given its power budget and a test there exists a supply voltage that minimizes the test time. An analysis determines whether the shortest test must use a synchronous or an asynchronous clock.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信