{"title":"喷涂聚氨酯泡沫长期导热系数的温度依赖性","authors":"N. Holcroft","doi":"10.1177/17442591211045415","DOIUrl":null,"url":null,"abstract":"The thermal properties of closed-cell foam insulation display a more complex behaviour than other construction materials due to the properties of the blowing agent captured in their cellular structure. Over time, blowing agent diffuses out from and air into the cellular structure resulting in an increase in thermal conductivity, a process that is temperature dependent. Some blowing agents also condense at temperatures within the in-service range of the insulation, resulting in non-linear temperature dependent relationships. Moreover, diffusion of moisture into the cellular structure increases thermal conductivity. Standards exist to quantify the effect of gas diffusion on thermal conductivity, however only at standard laboratory conditions. In this paper a new test procedure is described that includes calculation methods to determine Temperature Dependent Long-Term Thermal Conductivity (LTTC(T)) functions for closed-cell foam insulation using as a test material, a Medium-Density Spray Polyurethane Foam (MDSPF). Tests results are provided to show the validity of the method and to investigate the effects of both conditioning and mean test temperature on change in thermal conductivity. In addition, testing was conducted to produce a moisture dependent thermal conductivity function. The resulting functions were used in hygrothermal simulations to assess the effect of foam aging, in-service temperature and moisture content on the performance of a typical wall assembly incorporating MDSPF located in four Canadian climate zones. Results show that after 1 year, mean thermal conductivity increased 15%–16% and after 5 years 23%–24%, depending on climate zone. Furthermore, the use of the LTTC(T) function to calculate the wall assembly U-value improved accuracy between 3% and 5%.","PeriodicalId":50249,"journal":{"name":"Journal of Building Physics","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2021-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Temperature dependency of the long-term thermal conductivity of spray polyurethane foam\",\"authors\":\"N. Holcroft\",\"doi\":\"10.1177/17442591211045415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The thermal properties of closed-cell foam insulation display a more complex behaviour than other construction materials due to the properties of the blowing agent captured in their cellular structure. Over time, blowing agent diffuses out from and air into the cellular structure resulting in an increase in thermal conductivity, a process that is temperature dependent. Some blowing agents also condense at temperatures within the in-service range of the insulation, resulting in non-linear temperature dependent relationships. Moreover, diffusion of moisture into the cellular structure increases thermal conductivity. Standards exist to quantify the effect of gas diffusion on thermal conductivity, however only at standard laboratory conditions. In this paper a new test procedure is described that includes calculation methods to determine Temperature Dependent Long-Term Thermal Conductivity (LTTC(T)) functions for closed-cell foam insulation using as a test material, a Medium-Density Spray Polyurethane Foam (MDSPF). Tests results are provided to show the validity of the method and to investigate the effects of both conditioning and mean test temperature on change in thermal conductivity. In addition, testing was conducted to produce a moisture dependent thermal conductivity function. The resulting functions were used in hygrothermal simulations to assess the effect of foam aging, in-service temperature and moisture content on the performance of a typical wall assembly incorporating MDSPF located in four Canadian climate zones. Results show that after 1 year, mean thermal conductivity increased 15%–16% and after 5 years 23%–24%, depending on climate zone. Furthermore, the use of the LTTC(T) function to calculate the wall assembly U-value improved accuracy between 3% and 5%.\",\"PeriodicalId\":50249,\"journal\":{\"name\":\"Journal of Building Physics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2021-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Building Physics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/17442591211045415\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Building Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/17442591211045415","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Temperature dependency of the long-term thermal conductivity of spray polyurethane foam
The thermal properties of closed-cell foam insulation display a more complex behaviour than other construction materials due to the properties of the blowing agent captured in their cellular structure. Over time, blowing agent diffuses out from and air into the cellular structure resulting in an increase in thermal conductivity, a process that is temperature dependent. Some blowing agents also condense at temperatures within the in-service range of the insulation, resulting in non-linear temperature dependent relationships. Moreover, diffusion of moisture into the cellular structure increases thermal conductivity. Standards exist to quantify the effect of gas diffusion on thermal conductivity, however only at standard laboratory conditions. In this paper a new test procedure is described that includes calculation methods to determine Temperature Dependent Long-Term Thermal Conductivity (LTTC(T)) functions for closed-cell foam insulation using as a test material, a Medium-Density Spray Polyurethane Foam (MDSPF). Tests results are provided to show the validity of the method and to investigate the effects of both conditioning and mean test temperature on change in thermal conductivity. In addition, testing was conducted to produce a moisture dependent thermal conductivity function. The resulting functions were used in hygrothermal simulations to assess the effect of foam aging, in-service temperature and moisture content on the performance of a typical wall assembly incorporating MDSPF located in four Canadian climate zones. Results show that after 1 year, mean thermal conductivity increased 15%–16% and after 5 years 23%–24%, depending on climate zone. Furthermore, the use of the LTTC(T) function to calculate the wall assembly U-value improved accuracy between 3% and 5%.
期刊介绍:
Journal of Building Physics (J. Bldg. Phys) is an international, peer-reviewed journal that publishes a high quality research and state of the art “integrated” papers to promote scientifically thorough advancement of all the areas of non-structural performance of a building and particularly in heat, air, moisture transfer.