具有多个远程增强手-机交互装置的呼吸检测系统的设计

Ying-Wen Bai, Cheng-Lung Tsai, Siao-Cian Wu
{"title":"具有多个远程增强手-机交互装置的呼吸检测系统的设计","authors":"Ying-Wen Bai, Cheng-Lung Tsai, Siao-Cian Wu","doi":"10.1109/ISCE.2012.6241714","DOIUrl":null,"url":null,"abstract":"In this paper we propose a design using multiple remotely enhanced hand-computer interaction devices (REHCID) to design a real-time breathing detection system. Due to the restricted detection angle of our previously proposed system, unstable detection can be encountered when patients turn the body over. Our new REHCID placed on both sides of the bed allow the system to detect the patient's breathing regardless of his posture. Our design uses both an Infrared (IR) illuminator projected onto the patient's chest and an IR camera to detect the location of the IR LED. We then transport the IR location to the computer by means of Bluetooth. As the infrared rays are invisible, this design can still detect effectively in a dim environment, without at all influencing the quality of the patient's sleep.","PeriodicalId":6297,"journal":{"name":"2012 IEEE 16th International Symposium on Consumer Electronics","volume":"365 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Design of a breath detection system with multiple remotely enhanced hand-computer interaction devices\",\"authors\":\"Ying-Wen Bai, Cheng-Lung Tsai, Siao-Cian Wu\",\"doi\":\"10.1109/ISCE.2012.6241714\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper we propose a design using multiple remotely enhanced hand-computer interaction devices (REHCID) to design a real-time breathing detection system. Due to the restricted detection angle of our previously proposed system, unstable detection can be encountered when patients turn the body over. Our new REHCID placed on both sides of the bed allow the system to detect the patient's breathing regardless of his posture. Our design uses both an Infrared (IR) illuminator projected onto the patient's chest and an IR camera to detect the location of the IR LED. We then transport the IR location to the computer by means of Bluetooth. As the infrared rays are invisible, this design can still detect effectively in a dim environment, without at all influencing the quality of the patient's sleep.\",\"PeriodicalId\":6297,\"journal\":{\"name\":\"2012 IEEE 16th International Symposium on Consumer Electronics\",\"volume\":\"365 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE 16th International Symposium on Consumer Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISCE.2012.6241714\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE 16th International Symposium on Consumer Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISCE.2012.6241714","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文提出了一种利用多远程增强手-机交互装置(REHCID)来设计实时呼吸检测系统的设计方案。由于我们之前提出的系统检测角度有限,当患者翻身时可能会遇到检测不稳定的情况。我们的新REHCID放置在床的两侧,允许系统检测病人的呼吸,而不管他的姿势。我们的设计使用了一个投射到患者胸部的红外(IR)照明器和一个红外摄像机来检测红外LED的位置。然后,我们通过蓝牙将红外位置传输到计算机。由于红外线是不可见的,这种设计在昏暗的环境中仍然可以有效地进行检测,而不会影响患者的睡眠质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of a breath detection system with multiple remotely enhanced hand-computer interaction devices
In this paper we propose a design using multiple remotely enhanced hand-computer interaction devices (REHCID) to design a real-time breathing detection system. Due to the restricted detection angle of our previously proposed system, unstable detection can be encountered when patients turn the body over. Our new REHCID placed on both sides of the bed allow the system to detect the patient's breathing regardless of his posture. Our design uses both an Infrared (IR) illuminator projected onto the patient's chest and an IR camera to detect the location of the IR LED. We then transport the IR location to the computer by means of Bluetooth. As the infrared rays are invisible, this design can still detect effectively in a dim environment, without at all influencing the quality of the patient's sleep.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信