对角技术中的外部标记:一种减少牙科放射成像误差的新方法

IF 0.1 Q4 MEDICINE, GENERAL & INTERNAL
Azizah Ahmad Fauzi, Muhamad Aqil Aa, Z. MohdAmirul, A. Atika
{"title":"对角技术中的外部标记:一种减少牙科放射成像误差的新方法","authors":"Azizah Ahmad Fauzi, Muhamad Aqil Aa, Z. MohdAmirul, A. Atika","doi":"10.17576/MH.2017.1202.14","DOIUrl":null,"url":null,"abstract":"Bisecting-angle-technique is a method used to improve patient comfort during periapical radiography. This technique is usually performed without X-ray beam aiming device and has been commonly associated with dental radiographic error. \nThe use of external marker as a beam aiming device in bisecting-angle-technique is potentially effective to reduce the number of errors occurring during periapical radiography. In this study, 240 periapical radiographs were taken by undergraduate dental students. Periapical radiographs were taken using traditional method of bisecting-angle-technique (BAT), bisecting-angle-technique with the use of external marker (BAT-M) and the standard method in periapical radiography; paralleling technique (PT). All radiographic images were evaluated and errors were classified and tabled according to the type and number of errors. Chi-square test was used to compare the total number of radiographic errors made using these three techniques. One of the most common errors with BAT was cone cut error (13.8%). This error had been markedly reduced to 1.3% and 2.5% by implementation of BAT-M and PT, respectively. The total number of errors was also found to be significantly lesser for BAT-M compared to BAT, p< 0.05.","PeriodicalId":53946,"journal":{"name":"Medicine and Health","volume":"7 1","pages":"304-311"},"PeriodicalIF":0.1000,"publicationDate":"2017-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"External marker in bisecting-angle-technique: a new approach to minimize dental radiographic error\",\"authors\":\"Azizah Ahmad Fauzi, Muhamad Aqil Aa, Z. MohdAmirul, A. Atika\",\"doi\":\"10.17576/MH.2017.1202.14\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bisecting-angle-technique is a method used to improve patient comfort during periapical radiography. This technique is usually performed without X-ray beam aiming device and has been commonly associated with dental radiographic error. \\nThe use of external marker as a beam aiming device in bisecting-angle-technique is potentially effective to reduce the number of errors occurring during periapical radiography. In this study, 240 periapical radiographs were taken by undergraduate dental students. Periapical radiographs were taken using traditional method of bisecting-angle-technique (BAT), bisecting-angle-technique with the use of external marker (BAT-M) and the standard method in periapical radiography; paralleling technique (PT). All radiographic images were evaluated and errors were classified and tabled according to the type and number of errors. Chi-square test was used to compare the total number of radiographic errors made using these three techniques. One of the most common errors with BAT was cone cut error (13.8%). This error had been markedly reduced to 1.3% and 2.5% by implementation of BAT-M and PT, respectively. The total number of errors was also found to be significantly lesser for BAT-M compared to BAT, p< 0.05.\",\"PeriodicalId\":53946,\"journal\":{\"name\":\"Medicine and Health\",\"volume\":\"7 1\",\"pages\":\"304-311\"},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2017-12-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medicine and Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.17576/MH.2017.1202.14\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine and Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.17576/MH.2017.1202.14","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 2

摘要

切分角技术是一种在根尖周造影中提高患者舒适度的方法。该技术通常在没有x射线束瞄准装置的情况下进行,并且通常与牙科放射成像误差有关。在切分角技术中使用外部标记作为光束瞄准装置,可以有效地减少根尖周围放射照相中发生的错误数量。在本研究中,240名牙科本科生拍摄根尖周x线片。根尖周x线片采用传统的对角技术(BAT)、外部标记对角技术(BAT- m)和根尖周x线片标准方法拍摄;并行技术(PT)。对所有放射图像进行评估,并根据错误的类型和数量对错误进行分类和表列。卡方检验用于比较使用这三种技术所产生的放射照相误差总数。BAT最常见的错误之一是锥体切割错误(13.8%)。通过实施BAT-M和PT,这一误差分别显著降低到1.3%和2.5%。与BAT相比,BAT- m的总错误数也明显减少,p< 0.05。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
External marker in bisecting-angle-technique: a new approach to minimize dental radiographic error
Bisecting-angle-technique is a method used to improve patient comfort during periapical radiography. This technique is usually performed without X-ray beam aiming device and has been commonly associated with dental radiographic error. The use of external marker as a beam aiming device in bisecting-angle-technique is potentially effective to reduce the number of errors occurring during periapical radiography. In this study, 240 periapical radiographs were taken by undergraduate dental students. Periapical radiographs were taken using traditional method of bisecting-angle-technique (BAT), bisecting-angle-technique with the use of external marker (BAT-M) and the standard method in periapical radiography; paralleling technique (PT). All radiographic images were evaluated and errors were classified and tabled according to the type and number of errors. Chi-square test was used to compare the total number of radiographic errors made using these three techniques. One of the most common errors with BAT was cone cut error (13.8%). This error had been markedly reduced to 1.3% and 2.5% by implementation of BAT-M and PT, respectively. The total number of errors was also found to be significantly lesser for BAT-M compared to BAT, p< 0.05.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medicine and Health
Medicine and Health MEDICINE, GENERAL & INTERNAL-
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信