{"title":"HPLC法测定大鼠血浆中丹皮酚含量及药动学研究","authors":"C. Xiaolan","doi":"10.4268/CJCMM20102108","DOIUrl":null,"url":null,"abstract":"OBJECTIVE: To establish a sensitive HPLC method for determining the concentrations of paeonol in rat plasma and to evaluate its pharmacokinetic characteristics. METHOD: The paeonol from eortex Moutan was distilled by the way of water-vapor. A single i.v. dose of 4 mg x kg(-1) paeonol injection was given to 5 health rats. Paeonol was separated on a Diamonsil -C18 column with methanol-water (60: 40)as mobile phase. The plasma concentrations of paeonol were determined and its pharmacokinetic parameters were calculated and evaluated by using kinetica 4.0. RESULT: The linear range of the method for paeonol was 0.204-20.4 mg x L(-1) and the determination limit was 0.204 mg x L(-1). The main pharmacokinetic parameters, such as AUC, MRT, C(max), Kel, t(1/2kel), after a single dose of paeonol injection were (111.88 +/- 14.44) mg x L(-1) x min(-1), (23.25 +/- 5.86) min, (8.99 +/- 0.84) mg x L(-1), (0.082 +/- 0.015) min(-1) and (8.73 +/- 1.54) min, respectively. CONCLUSION: The HPLC method for determining paeonol concentration in plasma is simple, rapid, sensitive and suitable for pharmacokinetic studies.","PeriodicalId":9835,"journal":{"name":"China Journal of Chinese Matera Medica","volume":"55 1","pages":"2826"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Determination of paeonol in rat plasma by HPLC and pharmacokinetic study\",\"authors\":\"C. Xiaolan\",\"doi\":\"10.4268/CJCMM20102108\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVE: To establish a sensitive HPLC method for determining the concentrations of paeonol in rat plasma and to evaluate its pharmacokinetic characteristics. METHOD: The paeonol from eortex Moutan was distilled by the way of water-vapor. A single i.v. dose of 4 mg x kg(-1) paeonol injection was given to 5 health rats. Paeonol was separated on a Diamonsil -C18 column with methanol-water (60: 40)as mobile phase. The plasma concentrations of paeonol were determined and its pharmacokinetic parameters were calculated and evaluated by using kinetica 4.0. RESULT: The linear range of the method for paeonol was 0.204-20.4 mg x L(-1) and the determination limit was 0.204 mg x L(-1). The main pharmacokinetic parameters, such as AUC, MRT, C(max), Kel, t(1/2kel), after a single dose of paeonol injection were (111.88 +/- 14.44) mg x L(-1) x min(-1), (23.25 +/- 5.86) min, (8.99 +/- 0.84) mg x L(-1), (0.082 +/- 0.015) min(-1) and (8.73 +/- 1.54) min, respectively. CONCLUSION: The HPLC method for determining paeonol concentration in plasma is simple, rapid, sensitive and suitable for pharmacokinetic studies.\",\"PeriodicalId\":9835,\"journal\":{\"name\":\"China Journal of Chinese Matera Medica\",\"volume\":\"55 1\",\"pages\":\"2826\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"China Journal of Chinese Matera Medica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4268/CJCMM20102108\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"China Journal of Chinese Matera Medica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4268/CJCMM20102108","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determination of paeonol in rat plasma by HPLC and pharmacokinetic study
OBJECTIVE: To establish a sensitive HPLC method for determining the concentrations of paeonol in rat plasma and to evaluate its pharmacokinetic characteristics. METHOD: The paeonol from eortex Moutan was distilled by the way of water-vapor. A single i.v. dose of 4 mg x kg(-1) paeonol injection was given to 5 health rats. Paeonol was separated on a Diamonsil -C18 column with methanol-water (60: 40)as mobile phase. The plasma concentrations of paeonol were determined and its pharmacokinetic parameters were calculated and evaluated by using kinetica 4.0. RESULT: The linear range of the method for paeonol was 0.204-20.4 mg x L(-1) and the determination limit was 0.204 mg x L(-1). The main pharmacokinetic parameters, such as AUC, MRT, C(max), Kel, t(1/2kel), after a single dose of paeonol injection were (111.88 +/- 14.44) mg x L(-1) x min(-1), (23.25 +/- 5.86) min, (8.99 +/- 0.84) mg x L(-1), (0.082 +/- 0.015) min(-1) and (8.73 +/- 1.54) min, respectively. CONCLUSION: The HPLC method for determining paeonol concentration in plasma is simple, rapid, sensitive and suitable for pharmacokinetic studies.