一种基于AuPd@FexOy纳米酶的电化学传感器,用于实际样品中过氧化氢的敏感和原位定量检测。

Mengjiao Dai, Qunyan Zhu, Dongxue Han, L. Niu, Zhenxin Wang
{"title":"一种基于AuPd@FexOy纳米酶的电化学传感器,用于实际样品中过氧化氢的敏感和原位定量检测。","authors":"Mengjiao Dai, Qunyan Zhu, Dongxue Han, L. Niu, Zhenxin Wang","doi":"10.2139/ssrn.4165889","DOIUrl":null,"url":null,"abstract":"The hydrogen peroxide (H2O2) levels in living organisms and environment have strong effects on many biological processes inducing cell apoptosis/cell necrosis and wound disinfection. Therefore, it is important to have an accurate and in situ detection of H2O2. Herein, an AuPd@FexOy nanozyme-based electrochemical (EC) sensor (termed as AuPd@FexOy NPs/GCE) with good stability and anti-interference ability has been prepared for the detection of H2O2 by differential pulse voltammetry (DPV) and chronoamperometry dual-measurement modes. The AuPd@FexOy NPs/GCE exhibits good linear relationships in the ranges from 13.0 to 6.0 × 103 μM (DPV measurement) and 50 to 1.0 × 103 μM (chronoamperometry measurement), low detection limits (LODs) of 1.6 μM (DPV measurement) and 3.0 μM (chronoamperometry measurement) and high sensitivities of 83.8 nA μM-1 cm-2 (DPV measurement) and 120.7 nA μM-1 cm-2 (chronoamperometry measurement). The practicability of the as-prepared AuPd@FexOy NPs/GCE has been demonstrated by an in situ real-time detection of H2O2 released from adherent living MCF-7 cells triggered by varying amounts of N-formyl-L-methionyl-L-leucyl-L-phenylalanine (FMLP) from 0.5 to 3.0 μM and the quantitative determination of H2O2 in commercial disinfectants.","PeriodicalId":82956,"journal":{"name":"The Behavior analyst","volume":"2002 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"An electrochemical sensor based on AuPd@FexOy nanozymes for a sensitive and in situ quantitative detection of hydrogen peroxide in real samples.\",\"authors\":\"Mengjiao Dai, Qunyan Zhu, Dongxue Han, L. Niu, Zhenxin Wang\",\"doi\":\"10.2139/ssrn.4165889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The hydrogen peroxide (H2O2) levels in living organisms and environment have strong effects on many biological processes inducing cell apoptosis/cell necrosis and wound disinfection. Therefore, it is important to have an accurate and in situ detection of H2O2. Herein, an AuPd@FexOy nanozyme-based electrochemical (EC) sensor (termed as AuPd@FexOy NPs/GCE) with good stability and anti-interference ability has been prepared for the detection of H2O2 by differential pulse voltammetry (DPV) and chronoamperometry dual-measurement modes. The AuPd@FexOy NPs/GCE exhibits good linear relationships in the ranges from 13.0 to 6.0 × 103 μM (DPV measurement) and 50 to 1.0 × 103 μM (chronoamperometry measurement), low detection limits (LODs) of 1.6 μM (DPV measurement) and 3.0 μM (chronoamperometry measurement) and high sensitivities of 83.8 nA μM-1 cm-2 (DPV measurement) and 120.7 nA μM-1 cm-2 (chronoamperometry measurement). The practicability of the as-prepared AuPd@FexOy NPs/GCE has been demonstrated by an in situ real-time detection of H2O2 released from adherent living MCF-7 cells triggered by varying amounts of N-formyl-L-methionyl-L-leucyl-L-phenylalanine (FMLP) from 0.5 to 3.0 μM and the quantitative determination of H2O2 in commercial disinfectants.\",\"PeriodicalId\":82956,\"journal\":{\"name\":\"The Behavior analyst\",\"volume\":\"2002 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Behavior analyst\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2139/ssrn.4165889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Behavior analyst","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2139/ssrn.4165889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

生物和环境中的过氧化氢(H2O2)水平对诱导细胞凋亡/细胞坏死和伤口消毒的许多生物过程有很强的影响。因此,对H2O2进行准确的原位检测非常重要。本文制备了一种稳定性好、抗干扰能力强的AuPd@FexOy纳米酶电化学(EC)传感器(AuPd@FexOy NPs/GCE),用于差分脉冲伏安法(DPV)和计时安培法双测量模式下检测H2O2。AuPd@FexOy NPs/GCE在13.0 ~ 6.0 × 103 μM (DPV测量)和50 ~ 1.0 × 103 μM(计时电流测量)范围内呈良好的线性关系,低检出限(lod)为1.6 μM (DPV测量)和3.0 μM(计时电流测量),高灵敏度为83.8 nA μM-1 cm-2 (DPV测量)和120.7 nA μM-1 cm-2(计时电流测量)。通过原位实时检测0.5 ~ 3.0 μM n -甲氧基-l -甲氧基-l -leucyl- l-苯丙氨酸(FMLP)触发MCF-7细胞释放的H2O2,以及商用消毒剂中H2O2的定量测定,证明了AuPd@FexOy NPs/GCE的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An electrochemical sensor based on AuPd@FexOy nanozymes for a sensitive and in situ quantitative detection of hydrogen peroxide in real samples.
The hydrogen peroxide (H2O2) levels in living organisms and environment have strong effects on many biological processes inducing cell apoptosis/cell necrosis and wound disinfection. Therefore, it is important to have an accurate and in situ detection of H2O2. Herein, an AuPd@FexOy nanozyme-based electrochemical (EC) sensor (termed as AuPd@FexOy NPs/GCE) with good stability and anti-interference ability has been prepared for the detection of H2O2 by differential pulse voltammetry (DPV) and chronoamperometry dual-measurement modes. The AuPd@FexOy NPs/GCE exhibits good linear relationships in the ranges from 13.0 to 6.0 × 103 μM (DPV measurement) and 50 to 1.0 × 103 μM (chronoamperometry measurement), low detection limits (LODs) of 1.6 μM (DPV measurement) and 3.0 μM (chronoamperometry measurement) and high sensitivities of 83.8 nA μM-1 cm-2 (DPV measurement) and 120.7 nA μM-1 cm-2 (chronoamperometry measurement). The practicability of the as-prepared AuPd@FexOy NPs/GCE has been demonstrated by an in situ real-time detection of H2O2 released from adherent living MCF-7 cells triggered by varying amounts of N-formyl-L-methionyl-L-leucyl-L-phenylalanine (FMLP) from 0.5 to 3.0 μM and the quantitative determination of H2O2 in commercial disinfectants.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信