基于小波包的并网光伏逆变器无源孤岛检测方法

Hieu Thanh Do, Xing Zhang, Haoyuan Li, Fei Li, T. T. Chu, Nguyen Viet
{"title":"基于小波包的并网光伏逆变器无源孤岛检测方法","authors":"Hieu Thanh Do, Xing Zhang, Haoyuan Li, Fei Li, T. T. Chu, Nguyen Viet","doi":"10.1109/IPEMC.2016.7512525","DOIUrl":null,"url":null,"abstract":"In this paper, a new passive islanding detection method for grid-connected photovoltaic inverters is proposed. The proposed method is based on extracting signatures from the high frequency components of voltage at the point of common coupling (PCC), which occur after an islanding condition. These high frequency components contain signature information capable of identifying the islanding condition. The PCC voltage is measured and its high frequency sub-band contents are extracted using wavelet packet transform (WPT). This characterization helps to provide enough information to efficiently detect and discriminate the effect of load switching disturbances and grid voltage distortions from islanding conditions. The effectiveness of the proposed method is tested in simulation of a grid-connected inverter system. The simulation results, carried out by Matlab/Simulink are used to validate the performance of the proposed method. The results demonstrate that the proposed method can detected within one cycle (20 ms), even with small non-detection zone and can discriminate between islanding and other events in the system, as load switching disturbances and grid voltage distortions.","PeriodicalId":6857,"journal":{"name":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","volume":"394 1","pages":"1566-1570"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Wavelet packet-based passive islanding detection method for grid connected photovoltaic inverters\",\"authors\":\"Hieu Thanh Do, Xing Zhang, Haoyuan Li, Fei Li, T. T. Chu, Nguyen Viet\",\"doi\":\"10.1109/IPEMC.2016.7512525\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a new passive islanding detection method for grid-connected photovoltaic inverters is proposed. The proposed method is based on extracting signatures from the high frequency components of voltage at the point of common coupling (PCC), which occur after an islanding condition. These high frequency components contain signature information capable of identifying the islanding condition. The PCC voltage is measured and its high frequency sub-band contents are extracted using wavelet packet transform (WPT). This characterization helps to provide enough information to efficiently detect and discriminate the effect of load switching disturbances and grid voltage distortions from islanding conditions. The effectiveness of the proposed method is tested in simulation of a grid-connected inverter system. The simulation results, carried out by Matlab/Simulink are used to validate the performance of the proposed method. The results demonstrate that the proposed method can detected within one cycle (20 ms), even with small non-detection zone and can discriminate between islanding and other events in the system, as load switching disturbances and grid voltage distortions.\",\"PeriodicalId\":6857,\"journal\":{\"name\":\"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)\",\"volume\":\"394 1\",\"pages\":\"1566-1570\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2016.7512525\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2016.7512525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文提出了一种新的并网光伏逆变器无源孤岛检测方法。该方法基于在孤岛状态后,从共耦合点(PCC)的电压高频分量中提取特征。这些高频成分包含能够识别孤岛状态的特征信息。测量PCC电压,利用小波包变换提取其高频子带内容。这种特性有助于提供足够的信息,以有效地检测和区分负载切换干扰和电网电压畸变与孤岛条件的影响。在并网逆变器系统仿真中验证了该方法的有效性。利用Matlab/Simulink进行仿真,验证了该方法的有效性。结果表明,该方法可以在一个周期(20 ms)内进行检测,即使有很小的非检测区域,并且可以区分孤岛和系统中的其他事件,如负载切换干扰和电网电压畸变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wavelet packet-based passive islanding detection method for grid connected photovoltaic inverters
In this paper, a new passive islanding detection method for grid-connected photovoltaic inverters is proposed. The proposed method is based on extracting signatures from the high frequency components of voltage at the point of common coupling (PCC), which occur after an islanding condition. These high frequency components contain signature information capable of identifying the islanding condition. The PCC voltage is measured and its high frequency sub-band contents are extracted using wavelet packet transform (WPT). This characterization helps to provide enough information to efficiently detect and discriminate the effect of load switching disturbances and grid voltage distortions from islanding conditions. The effectiveness of the proposed method is tested in simulation of a grid-connected inverter system. The simulation results, carried out by Matlab/Simulink are used to validate the performance of the proposed method. The results demonstrate that the proposed method can detected within one cycle (20 ms), even with small non-detection zone and can discriminate between islanding and other events in the system, as load switching disturbances and grid voltage distortions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信