{"title":"高选择性和灵敏度的DNA测量微电阻抗谱","authors":"Sang Wook Lee, T. Yamamoto, Teruo Fujii","doi":"10.1109/SENSOR.2005.1497322","DOIUrl":null,"url":null,"abstract":"A novel /spl mu/-EIS (microelectrical impedance spectroscopy) device for label free analysis of DNA are developed and experimentally demonstrated. The feature of /spl mu/-EIS system is not only detecting DNA without any labelling, but also controlling the conformation that would enhance the EIS signal. The /spl mu/-EIS system is fully integrated with a microfluidic network made of polydimethylsiloxane (PDMS), a micromeasurement electrode and a micropump in order to conduct a semiautomated measurement controlled by an external PC system. The micro EIS system is capable of detecting the DNA concentration of a few nM in aqueous solution of a few pl in volume by virtue of the conformation enhanced impedance response. As a first demonstration of conformational change induced DNA analysis, the frequency and the electric field strength dependence of various length and concentrations of DNA were evaluated.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"20 1","pages":"1314-1317 Vol. 2"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Highly selective and sensitive DNA measurement by microelectrical impedance spectroscopy\",\"authors\":\"Sang Wook Lee, T. Yamamoto, Teruo Fujii\",\"doi\":\"10.1109/SENSOR.2005.1497322\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel /spl mu/-EIS (microelectrical impedance spectroscopy) device for label free analysis of DNA are developed and experimentally demonstrated. The feature of /spl mu/-EIS system is not only detecting DNA without any labelling, but also controlling the conformation that would enhance the EIS signal. The /spl mu/-EIS system is fully integrated with a microfluidic network made of polydimethylsiloxane (PDMS), a micromeasurement electrode and a micropump in order to conduct a semiautomated measurement controlled by an external PC system. The micro EIS system is capable of detecting the DNA concentration of a few nM in aqueous solution of a few pl in volume by virtue of the conformation enhanced impedance response. As a first demonstration of conformational change induced DNA analysis, the frequency and the electric field strength dependence of various length and concentrations of DNA were evaluated.\",\"PeriodicalId\":22359,\"journal\":{\"name\":\"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.\",\"volume\":\"20 1\",\"pages\":\"1314-1317 Vol. 2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2005.1497322\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2005.1497322","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Highly selective and sensitive DNA measurement by microelectrical impedance spectroscopy
A novel /spl mu/-EIS (microelectrical impedance spectroscopy) device for label free analysis of DNA are developed and experimentally demonstrated. The feature of /spl mu/-EIS system is not only detecting DNA without any labelling, but also controlling the conformation that would enhance the EIS signal. The /spl mu/-EIS system is fully integrated with a microfluidic network made of polydimethylsiloxane (PDMS), a micromeasurement electrode and a micropump in order to conduct a semiautomated measurement controlled by an external PC system. The micro EIS system is capable of detecting the DNA concentration of a few nM in aqueous solution of a few pl in volume by virtue of the conformation enhanced impedance response. As a first demonstration of conformational change induced DNA analysis, the frequency and the electric field strength dependence of various length and concentrations of DNA were evaluated.