{"title":"用于谐波抑制和无功功率控制的级联h桥五电平逆变器","authors":"D.S.Chavan, Mukund S.Mahagaonkar","doi":"10.15662/IJAREEIE.2015.0403006","DOIUrl":null,"url":null,"abstract":"Distribution Static Compensator (DSTATCOM) which based on multi-Level Cascaded H - bridge (CHB) Inverter for mitigation of harmonics and compensation of reactive power in Power System. This CHB based inverter provides low harmonic distortion, reduced number of switches and suppression of switching losses. It also helps to improve the power factor and eliminate the Total Harmonics Distortion (THD). Proportional and Integral (PI) control is used for capacitor dc voltage regulation. A level shifted PWM (LSPWM) technique is used to analyse the performance of CHB Inverter. A CHB Inverter is considered for shunt compensation of 11kV distribution system. The results are obtained through MATLAB & Simulink software.","PeriodicalId":13702,"journal":{"name":"International Journal of Advanced Research in Electrical, Electronics and Instrumentation Energy","volume":"401 1","pages":"1216-1223"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cascaded H-Bridge Five Level Inverter forHarmonics Mitigation and Reactive PowerControl\",\"authors\":\"D.S.Chavan, Mukund S.Mahagaonkar\",\"doi\":\"10.15662/IJAREEIE.2015.0403006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distribution Static Compensator (DSTATCOM) which based on multi-Level Cascaded H - bridge (CHB) Inverter for mitigation of harmonics and compensation of reactive power in Power System. This CHB based inverter provides low harmonic distortion, reduced number of switches and suppression of switching losses. It also helps to improve the power factor and eliminate the Total Harmonics Distortion (THD). Proportional and Integral (PI) control is used for capacitor dc voltage regulation. A level shifted PWM (LSPWM) technique is used to analyse the performance of CHB Inverter. A CHB Inverter is considered for shunt compensation of 11kV distribution system. The results are obtained through MATLAB & Simulink software.\",\"PeriodicalId\":13702,\"journal\":{\"name\":\"International Journal of Advanced Research in Electrical, Electronics and Instrumentation Energy\",\"volume\":\"401 1\",\"pages\":\"1216-1223\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Advanced Research in Electrical, Electronics and Instrumentation Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15662/IJAREEIE.2015.0403006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advanced Research in Electrical, Electronics and Instrumentation Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15662/IJAREEIE.2015.0403006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Cascaded H-Bridge Five Level Inverter forHarmonics Mitigation and Reactive PowerControl
Distribution Static Compensator (DSTATCOM) which based on multi-Level Cascaded H - bridge (CHB) Inverter for mitigation of harmonics and compensation of reactive power in Power System. This CHB based inverter provides low harmonic distortion, reduced number of switches and suppression of switching losses. It also helps to improve the power factor and eliminate the Total Harmonics Distortion (THD). Proportional and Integral (PI) control is used for capacitor dc voltage regulation. A level shifted PWM (LSPWM) technique is used to analyse the performance of CHB Inverter. A CHB Inverter is considered for shunt compensation of 11kV distribution system. The results are obtained through MATLAB & Simulink software.