矩阵变换器自适应控制方法的仿真与分析

M. Kumar, U. Reddy, J.N.Ch, R. Shekar
{"title":"矩阵变换器自适应控制方法的仿真与分析","authors":"M. Kumar, U. Reddy, J.N.Ch, R. Shekar","doi":"10.15662/IJAREEIE.2015.0402043","DOIUrl":null,"url":null,"abstract":"Since discovered, electrical energy became one of the world’s fastest growing energy technologies. Efficient and stable utilization of electrical energy is one of the most important problem. The major phenomena that effects on the quality of power supply is the harmonics caused by different loads connected to the grid, which are usually converters based on power electronic components. These are the main causes for the deterioration of power quality. This paper presents the harmonic compensation of linear loads fed by matrix converter and the performance of two types of controllers(namely, Adaptive Fuzzy control and Adaptive Neural Fuzzy Inference system) are compared, during balanced supply and abnormal grid conditions. The sinusoidal nature of output currents were preserved by using PWM method and optimum Venturini method employed for matrix converter.","PeriodicalId":13702,"journal":{"name":"International Journal of Advanced Research in Electrical, Electronics and Instrumentation Energy","volume":"266 1","pages":"908-917"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation and Analysis of Adaptive ControlMethod Employed for Matrix Converter\",\"authors\":\"M. Kumar, U. Reddy, J.N.Ch, R. Shekar\",\"doi\":\"10.15662/IJAREEIE.2015.0402043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Since discovered, electrical energy became one of the world’s fastest growing energy technologies. Efficient and stable utilization of electrical energy is one of the most important problem. The major phenomena that effects on the quality of power supply is the harmonics caused by different loads connected to the grid, which are usually converters based on power electronic components. These are the main causes for the deterioration of power quality. This paper presents the harmonic compensation of linear loads fed by matrix converter and the performance of two types of controllers(namely, Adaptive Fuzzy control and Adaptive Neural Fuzzy Inference system) are compared, during balanced supply and abnormal grid conditions. The sinusoidal nature of output currents were preserved by using PWM method and optimum Venturini method employed for matrix converter.\",\"PeriodicalId\":13702,\"journal\":{\"name\":\"International Journal of Advanced Research in Electrical, Electronics and Instrumentation Energy\",\"volume\":\"266 1\",\"pages\":\"908-917\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Advanced Research in Electrical, Electronics and Instrumentation Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15662/IJAREEIE.2015.0402043\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advanced Research in Electrical, Electronics and Instrumentation Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15662/IJAREEIE.2015.0402043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

自发现以来,电能成为世界上发展最快的能源技术之一。高效、稳定地利用电能是其中一个重要问题。影响供电质量的主要现象是接入电网的不同负载所产生的谐波,这些负载通常是基于电力电子元件的变流器。这些都是导致电能质量恶化的主要原因。本文比较了在供电平衡和电网异常情况下,矩阵变换器对线性负荷的谐波补偿以及两种控制器(自适应模糊控制和自适应神经模糊推理系统)的性能。采用PWM方法和矩阵变换器的最优文丘里尼方法保持了输出电流的正弦特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simulation and Analysis of Adaptive ControlMethod Employed for Matrix Converter
Since discovered, electrical energy became one of the world’s fastest growing energy technologies. Efficient and stable utilization of electrical energy is one of the most important problem. The major phenomena that effects on the quality of power supply is the harmonics caused by different loads connected to the grid, which are usually converters based on power electronic components. These are the main causes for the deterioration of power quality. This paper presents the harmonic compensation of linear loads fed by matrix converter and the performance of two types of controllers(namely, Adaptive Fuzzy control and Adaptive Neural Fuzzy Inference system) are compared, during balanced supply and abnormal grid conditions. The sinusoidal nature of output currents were preserved by using PWM method and optimum Venturini method employed for matrix converter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信