Purion XE™高能离子注入机的损伤工程

J. Deluca, S. Satoh, H. Chen, T. Fox, S. Kondratenko, R. Reece
{"title":"Purion XE™高能离子注入机的损伤工程","authors":"J. Deluca, S. Satoh, H. Chen, T. Fox, S. Kondratenko, R. Reece","doi":"10.1109/IIT.2014.6940022","DOIUrl":null,"url":null,"abstract":"Many IC and CIS manufacturers still rely heavily on batch high energy ion implanters such as the Axcelis HE3 and Paradigm XE systems. Angle control continues to become increasingly important with the scaling of devices and the increasing use of channeled implants to reduce the number of implant steps needed to produce a box-like dopant profile. The use of channeled implants limits the use of batch ion implanters for these applications due to the cone angle effect. The introduction of serial high energy ion implanters to replace the batch implanters has exposed subtle differences in damage characteristics related to the differences in tool architecture. Investigation into second order differences in the damage characteristics of the single wafer and batch implanters have resulted in the development of a new system for modifying the electrostatic scanning of the ion beam on the Purion XE with implications for improvement in damage reduction, low dose stability and utilization of the system's mechanical throughput limit.","PeriodicalId":6548,"journal":{"name":"2014 20th International Conference on Ion Implantation Technology (IIT)","volume":"31 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Damage engineering on Purion XE™ high energy ion implanter\",\"authors\":\"J. Deluca, S. Satoh, H. Chen, T. Fox, S. Kondratenko, R. Reece\",\"doi\":\"10.1109/IIT.2014.6940022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many IC and CIS manufacturers still rely heavily on batch high energy ion implanters such as the Axcelis HE3 and Paradigm XE systems. Angle control continues to become increasingly important with the scaling of devices and the increasing use of channeled implants to reduce the number of implant steps needed to produce a box-like dopant profile. The use of channeled implants limits the use of batch ion implanters for these applications due to the cone angle effect. The introduction of serial high energy ion implanters to replace the batch implanters has exposed subtle differences in damage characteristics related to the differences in tool architecture. Investigation into second order differences in the damage characteristics of the single wafer and batch implanters have resulted in the development of a new system for modifying the electrostatic scanning of the ion beam on the Purion XE with implications for improvement in damage reduction, low dose stability and utilization of the system's mechanical throughput limit.\",\"PeriodicalId\":6548,\"journal\":{\"name\":\"2014 20th International Conference on Ion Implantation Technology (IIT)\",\"volume\":\"31 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 20th International Conference on Ion Implantation Technology (IIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IIT.2014.6940022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 20th International Conference on Ion Implantation Technology (IIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IIT.2014.6940022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

许多IC和独联体制造商仍然严重依赖批高能离子离子注入机如Axcelis魁梧和范式XE系统。随着器件的缩放和沟道植入物的使用越来越多,角度控制变得越来越重要,以减少产生盒状掺杂物轮廓所需的植入步骤。由于锥角效应,通道植入物的使用限制了批离子植入物在这些应用中的使用。采用串联高能离子注入器取代批量注入器,暴露出与工具结构不同相关的损伤特征的细微差异。通过对单晶片和批量植入器的二阶损伤特性差异的研究,开发了一种新的系统,用于修改Purion XE上离子束的静电扫描,从而提高了损伤降低、低剂量稳定性和利用系统的机械吞吐量限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Damage engineering on Purion XE™ high energy ion implanter
Many IC and CIS manufacturers still rely heavily on batch high energy ion implanters such as the Axcelis HE3 and Paradigm XE systems. Angle control continues to become increasingly important with the scaling of devices and the increasing use of channeled implants to reduce the number of implant steps needed to produce a box-like dopant profile. The use of channeled implants limits the use of batch ion implanters for these applications due to the cone angle effect. The introduction of serial high energy ion implanters to replace the batch implanters has exposed subtle differences in damage characteristics related to the differences in tool architecture. Investigation into second order differences in the damage characteristics of the single wafer and batch implanters have resulted in the development of a new system for modifying the electrostatic scanning of the ion beam on the Purion XE with implications for improvement in damage reduction, low dose stability and utilization of the system's mechanical throughput limit.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信