利用自电位法诊断评价某化工废弃物填埋场污染水泄漏

IF 0.1 Q3 HISTORY
A. Gusev, V. L. Molyarenko, A. Pavlovsky, I. O. Prilutsky, S. V. Andrushko
{"title":"利用自电位法诊断评价某化工废弃物填埋场污染水泄漏","authors":"A. Gusev, V. L. Molyarenko, A. Pavlovsky, I. O. Prilutsky, S. V. Andrushko","doi":"10.17072/psu.geol.21.1.90","DOIUrl":null,"url":null,"abstract":"The main goal of the research is a diagnostic assessment of polluted water leaks from the chemical waste landfill site using the self-potential method integrated with other methods. The following tasks were to be solved: locating zones of contaminated water leakage from the drainage canals; detecting polluted water leaks from the sludge reservoir; identifying the discharge zones of contaminated groundwater into the swamps adjacent to the landfill. Electrical prospecting equipment ERA-MAX with non-polarizable electrodes of the VIRG system was used for field measurements. Two measuring techniques of the self-potential method were used: the fixed-base method (the measurement interval was 5 m) and the potential gradient method (measuring line MN = 5 m). The additional methods were as follows: geomagnetic microsurvey and phytoindication. The following diagnostic indicators were estab-lished for the zones of infiltration of contaminated waters from canals and sludge reservoirs: negative fixed-base potential anomalies or negative potential gradient anomalies of the natural electric field, which are characterized by the amplitude of 10-40 mV. The area of discharge of polluted groundwater into the surficial unit is indicated by a positive anomaly of the natural electric field (+ 20-47 mV), spatially associated with the zone of degradation of swamp vegetation","PeriodicalId":41257,"journal":{"name":"Vestnik Permskogo Universiteta-Istoriya-Perm University Herald-History","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DIAGNOSTIC ASSESSMENT OF POLLUTED WATER LEAKS FROM THE SITE OF A CHEMICAL PRODUCTION WASTE LANDFILL USING THE SELF-POTENTIAL METHOD\",\"authors\":\"A. Gusev, V. L. Molyarenko, A. Pavlovsky, I. O. Prilutsky, S. V. Andrushko\",\"doi\":\"10.17072/psu.geol.21.1.90\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main goal of the research is a diagnostic assessment of polluted water leaks from the chemical waste landfill site using the self-potential method integrated with other methods. The following tasks were to be solved: locating zones of contaminated water leakage from the drainage canals; detecting polluted water leaks from the sludge reservoir; identifying the discharge zones of contaminated groundwater into the swamps adjacent to the landfill. Electrical prospecting equipment ERA-MAX with non-polarizable electrodes of the VIRG system was used for field measurements. Two measuring techniques of the self-potential method were used: the fixed-base method (the measurement interval was 5 m) and the potential gradient method (measuring line MN = 5 m). The additional methods were as follows: geomagnetic microsurvey and phytoindication. The following diagnostic indicators were estab-lished for the zones of infiltration of contaminated waters from canals and sludge reservoirs: negative fixed-base potential anomalies or negative potential gradient anomalies of the natural electric field, which are characterized by the amplitude of 10-40 mV. The area of discharge of polluted groundwater into the surficial unit is indicated by a positive anomaly of the natural electric field (+ 20-47 mV), spatially associated with the zone of degradation of swamp vegetation\",\"PeriodicalId\":41257,\"journal\":{\"name\":\"Vestnik Permskogo Universiteta-Istoriya-Perm University Herald-History\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vestnik Permskogo Universiteta-Istoriya-Perm University Herald-History\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17072/psu.geol.21.1.90\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HISTORY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik Permskogo Universiteta-Istoriya-Perm University Herald-History","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17072/psu.geol.21.1.90","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HISTORY","Score":null,"Total":0}
引用次数: 0

摘要

本研究的主要目的是将自势法与其他方法相结合,对化学垃圾填埋场污染水泄漏进行诊断性评价。主要解决的问题有:排水渠污染渗漏区定位;检测污泥池泄漏的污水;确定污染地下水排入垃圾填埋场附近沼泽的排放区。采用VIRG系统非极化电极的电勘探设备ERA-MAX进行现场测量。自电位法采用固定基法(测量间隔为5 m)和电位梯度法(测量线MN = 5 m)两种测量方法,外加地磁微测量法和植物指示法。建立了渠道和污泥库污染水入渗区域的诊断指标:自然电场负固定基电位异常或负电位梯度异常,其特征为振幅为10-40 mV。污染地下水向地表单元排放的区域表现为自然电场正异常(+ 20 ~ 47 mV),空间上与沼泽植被退化区相关
本文章由计算机程序翻译,如有差异,请以英文原文为准。
DIAGNOSTIC ASSESSMENT OF POLLUTED WATER LEAKS FROM THE SITE OF A CHEMICAL PRODUCTION WASTE LANDFILL USING THE SELF-POTENTIAL METHOD
The main goal of the research is a diagnostic assessment of polluted water leaks from the chemical waste landfill site using the self-potential method integrated with other methods. The following tasks were to be solved: locating zones of contaminated water leakage from the drainage canals; detecting polluted water leaks from the sludge reservoir; identifying the discharge zones of contaminated groundwater into the swamps adjacent to the landfill. Electrical prospecting equipment ERA-MAX with non-polarizable electrodes of the VIRG system was used for field measurements. Two measuring techniques of the self-potential method were used: the fixed-base method (the measurement interval was 5 m) and the potential gradient method (measuring line MN = 5 m). The additional methods were as follows: geomagnetic microsurvey and phytoindication. The following diagnostic indicators were estab-lished for the zones of infiltration of contaminated waters from canals and sludge reservoirs: negative fixed-base potential anomalies or negative potential gradient anomalies of the natural electric field, which are characterized by the amplitude of 10-40 mV. The area of discharge of polluted groundwater into the surficial unit is indicated by a positive anomaly of the natural electric field (+ 20-47 mV), spatially associated with the zone of degradation of swamp vegetation
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
35
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信