2015年夏季中欧城市人体热舒适分析——以塞尔维亚诺维萨德为例

Q4 Social Sciences
D. Milošević, S. Savić, Danijela Arsenovic, Z. Lužanin, Jelena Dunjić
{"title":"2015年夏季中欧城市人体热舒适分析——以塞尔维亚诺维萨德为例","authors":"D. Milošević, S. Savić, Danijela Arsenovic, Z. Lužanin, Jelena Dunjić","doi":"10.2298/gsgd2001031m","DOIUrl":null,"url":null,"abstract":"Urban meteorological network (UMN) was established in the Central European City of Novi Sad (Serbia) based on \"local climate zones\" (LCZs) system. Physiologically Equivalent Temperature (PET) index was used for the assessment of outdoor thermal comfort in the \"built\" and \"land cover\" LCZ classes of Novi Sad. The index was calculated in the RayMan software based on the meteorological, physiological as well as building and vegetation data. Temporal analysis was performed for extreme heat stress days (PETmax ? 41 ?C), extreme heat stress hours (PETav ? 41 ?C) and days with occurrence of \"tropical nights\" (Tmin > 20 ?C) during exceptionally hot summer of 2015. Our results show that extreme heat stress hours are the least frequent in compact midrise LCZ 2, followed by dense trees LCZ A. On the contrary, countryside (low plants - LCZ D) showed to be the most uncomfortable area during daytime followed by compact low-rise areas (LCZ 3). Tropical nights are the most frequent in midrise LCZs 5 and 2 (40-46 nights) and decreasing towards open, sparsely built and natural LCZs (6-8 tropical nights in LCZs A and D). This is almost 800% decrease and it has implications for health and recreation of urban population and emphasizes the need for UMN development based on LCZ system.","PeriodicalId":35518,"journal":{"name":"Glasnik - Srpskog Geografskog Drustva","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of human thermal comfort in Central European City during summer of 2015: A case of Novi Sad (Serbia)\",\"authors\":\"D. Milošević, S. Savić, Danijela Arsenovic, Z. Lužanin, Jelena Dunjić\",\"doi\":\"10.2298/gsgd2001031m\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Urban meteorological network (UMN) was established in the Central European City of Novi Sad (Serbia) based on \\\"local climate zones\\\" (LCZs) system. Physiologically Equivalent Temperature (PET) index was used for the assessment of outdoor thermal comfort in the \\\"built\\\" and \\\"land cover\\\" LCZ classes of Novi Sad. The index was calculated in the RayMan software based on the meteorological, physiological as well as building and vegetation data. Temporal analysis was performed for extreme heat stress days (PETmax ? 41 ?C), extreme heat stress hours (PETav ? 41 ?C) and days with occurrence of \\\"tropical nights\\\" (Tmin > 20 ?C) during exceptionally hot summer of 2015. Our results show that extreme heat stress hours are the least frequent in compact midrise LCZ 2, followed by dense trees LCZ A. On the contrary, countryside (low plants - LCZ D) showed to be the most uncomfortable area during daytime followed by compact low-rise areas (LCZ 3). Tropical nights are the most frequent in midrise LCZs 5 and 2 (40-46 nights) and decreasing towards open, sparsely built and natural LCZs (6-8 tropical nights in LCZs A and D). This is almost 800% decrease and it has implications for health and recreation of urban population and emphasizes the need for UMN development based on LCZ system.\",\"PeriodicalId\":35518,\"journal\":{\"name\":\"Glasnik - Srpskog Geografskog Drustva\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Glasnik - Srpskog Geografskog Drustva\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2298/gsgd2001031m\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Social Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Glasnik - Srpskog Geografskog Drustva","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2298/gsgd2001031m","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Social Sciences","Score":null,"Total":0}
引用次数: 2

摘要

城市气象网络(UMN)是在中欧城市诺维萨德(塞尔维亚)建立的基于“地方气候带”(lccs)系统。采用生理等效温度(PET)指数对诺维萨德“建筑”和“土地覆盖”LCZ等级的室外热舒适进行了评价。该指数是在RayMan软件中根据气象、生理、建筑和植被数据计算出来的。对极端热应激日(PETmax ?41°C),极端热应激小时(PETav ?在2015年异常炎热的夏季,出现了“热带夜”(Tmin > 20℃)的天数。结果表明,中高层2区极端热胁迫时间最少,其次是树木密集的中高层a区,相反,乡村(低植物- LCZ D)是白天最不舒适的区域,其次是紧凑的低层3区(LCZ 3)。中高层5区和中高层2区热带夜最频繁(40-46夜),并逐渐减少。稀疏的自然LCZ (LCZ A和D的6-8个热带夜),这几乎减少了800%,这对城市人口的健康和娱乐有影响,并强调了基于LCZ系统的UMN发展的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of human thermal comfort in Central European City during summer of 2015: A case of Novi Sad (Serbia)
Urban meteorological network (UMN) was established in the Central European City of Novi Sad (Serbia) based on "local climate zones" (LCZs) system. Physiologically Equivalent Temperature (PET) index was used for the assessment of outdoor thermal comfort in the "built" and "land cover" LCZ classes of Novi Sad. The index was calculated in the RayMan software based on the meteorological, physiological as well as building and vegetation data. Temporal analysis was performed for extreme heat stress days (PETmax ? 41 ?C), extreme heat stress hours (PETav ? 41 ?C) and days with occurrence of "tropical nights" (Tmin > 20 ?C) during exceptionally hot summer of 2015. Our results show that extreme heat stress hours are the least frequent in compact midrise LCZ 2, followed by dense trees LCZ A. On the contrary, countryside (low plants - LCZ D) showed to be the most uncomfortable area during daytime followed by compact low-rise areas (LCZ 3). Tropical nights are the most frequent in midrise LCZs 5 and 2 (40-46 nights) and decreasing towards open, sparsely built and natural LCZs (6-8 tropical nights in LCZs A and D). This is almost 800% decrease and it has implications for health and recreation of urban population and emphasizes the need for UMN development based on LCZ system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Glasnik - Srpskog Geografskog Drustva
Glasnik - Srpskog Geografskog Drustva Social Sciences-Education
CiteScore
0.70
自引率
0.00%
发文量
11
审稿时长
18 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信