{"title":"基于苯并-18-冠-6和多壁碳纳米管化学修饰铅笔石墨电极测定水样中铅的研制","authors":"Walaa Haider Elobeid, A. Elbashir","doi":"10.33945/SAMI/PCBR.2019.2.2433","DOIUrl":null,"url":null,"abstract":"An improvement to the performance of the bare pencil graphite electrode (PGE) was made by modifying it utilizing p-amino benzene sulfonic acid (p-ABSA), benzo-18-crown-6 and multi-walled carbon nanotubes (CNTs) to detect lead (II) ions in water samples using differential pulse anodic stripping voltammetric technique. The presence of p-ABSA serves as ionic conductor while the good adsorption ability and electrical conductivity of multi-walled CNTs enhanced the sensitivity through increasing the electrochemical active surface area. Furthermore, using benzo-18-crown-6 as a molecular scavenger improved the selectivity for lead (II) ions. After optimizing the experimental and chemical parameters, the proposed electrode demonstrated linearity toward the lead (II) ions in a concentration range of 15-200 µM, and 0.99852 correlation factor at 5 sec accumulation time. The detection and qualification limits were statistically calculated based on ICH guidelines as 5.72 µM and 17.32 µM, respectively. The sensor demonstrated a very good selectivity over heavy metals for instance Zn (II), Fe (III), Cr (III), Cu (II) and Mn (VI). The developed method was adequately applied for the determination of Pb (II) ions in water samples. The results obtained by the current method were compared to the acquired results utilizing ICP-OES. According to the statistical consideration, the two methods were considered identical.","PeriodicalId":20668,"journal":{"name":"Progress in Chemical and Biochemical Research","volume":"28 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"Development of chemically modified pencil graphite electrode based on benzo-18-crown-6 and multi-walled CNTs for determination of lead in water samples\",\"authors\":\"Walaa Haider Elobeid, A. Elbashir\",\"doi\":\"10.33945/SAMI/PCBR.2019.2.2433\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An improvement to the performance of the bare pencil graphite electrode (PGE) was made by modifying it utilizing p-amino benzene sulfonic acid (p-ABSA), benzo-18-crown-6 and multi-walled carbon nanotubes (CNTs) to detect lead (II) ions in water samples using differential pulse anodic stripping voltammetric technique. The presence of p-ABSA serves as ionic conductor while the good adsorption ability and electrical conductivity of multi-walled CNTs enhanced the sensitivity through increasing the electrochemical active surface area. Furthermore, using benzo-18-crown-6 as a molecular scavenger improved the selectivity for lead (II) ions. After optimizing the experimental and chemical parameters, the proposed electrode demonstrated linearity toward the lead (II) ions in a concentration range of 15-200 µM, and 0.99852 correlation factor at 5 sec accumulation time. The detection and qualification limits were statistically calculated based on ICH guidelines as 5.72 µM and 17.32 µM, respectively. The sensor demonstrated a very good selectivity over heavy metals for instance Zn (II), Fe (III), Cr (III), Cu (II) and Mn (VI). The developed method was adequately applied for the determination of Pb (II) ions in water samples. The results obtained by the current method were compared to the acquired results utilizing ICP-OES. According to the statistical consideration, the two methods were considered identical.\",\"PeriodicalId\":20668,\"journal\":{\"name\":\"Progress in Chemical and Biochemical Research\",\"volume\":\"28 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Progress in Chemical and Biochemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33945/SAMI/PCBR.2019.2.2433\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Chemical and Biochemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33945/SAMI/PCBR.2019.2.2433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

利用对氨基苯磺酸(p-ABSA)、苯并-18-冠-6和多壁碳纳米管(CNTs)对裸铅笔石墨电极(PGE)进行改性,提高了PGE的性能,利用差分脉冲阳极溶出伏安技术检测水样中的铅离子。p-ABSA的存在起到离子导体的作用,而多壁CNTs良好的吸附能力和导电性通过增加电化学活性表面积增强了灵敏度。此外,使用苯并-18-冠-6作为分子清除剂提高了对铅(II)离子的选择性。优化实验参数和化学参数后,电极对铅(II)离子在15 ~ 200µM的浓度范围内呈线性,累积时间为5秒,相关系数为0.99852。根据ICH指南统计计算检测限和合格限分别为5.72µM和17.32µM。该传感器对Zn (II)、Fe (III)、Cr (III)、Cu (II)、Mn (VI)等重金属具有很好的选择性,可用于水样中Pb (II)离子的测定。将本方法所得结果与ICP-OES所得结果进行了比较。根据统计学上的考虑,认为这两种方法是相同的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of chemically modified pencil graphite electrode based on benzo-18-crown-6 and multi-walled CNTs for determination of lead in water samples
An improvement to the performance of the bare pencil graphite electrode (PGE) was made by modifying it utilizing p-amino benzene sulfonic acid (p-ABSA), benzo-18-crown-6 and multi-walled carbon nanotubes (CNTs) to detect lead (II) ions in water samples using differential pulse anodic stripping voltammetric technique. The presence of p-ABSA serves as ionic conductor while the good adsorption ability and electrical conductivity of multi-walled CNTs enhanced the sensitivity through increasing the electrochemical active surface area. Furthermore, using benzo-18-crown-6 as a molecular scavenger improved the selectivity for lead (II) ions. After optimizing the experimental and chemical parameters, the proposed electrode demonstrated linearity toward the lead (II) ions in a concentration range of 15-200 µM, and 0.99852 correlation factor at 5 sec accumulation time. The detection and qualification limits were statistically calculated based on ICH guidelines as 5.72 µM and 17.32 µM, respectively. The sensor demonstrated a very good selectivity over heavy metals for instance Zn (II), Fe (III), Cr (III), Cu (II) and Mn (VI). The developed method was adequately applied for the determination of Pb (II) ions in water samples. The results obtained by the current method were compared to the acquired results utilizing ICP-OES. According to the statistical consideration, the two methods were considered identical.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信