Al2O3/ Y-TSZ混合填料对PMMA义齿基托复合材料放射透明度的影响

A.O. Alhareb , H.M. Akil , Z.A. Ahmad
{"title":"Al2O3/ Y-TSZ混合填料对PMMA义齿基托复合材料放射透明度的影响","authors":"A.O. Alhareb ,&nbsp;H.M. Akil ,&nbsp;Z.A. Ahmad","doi":"10.1016/j.proche.2016.03.065","DOIUrl":null,"url":null,"abstract":"<div><p>The radiopacity of alumina/yttrium stabilizer zirconia (Al<sub>2</sub>O<sub>3</sub>/Y-TSZ) particles with nitrile butadiene rubber (NBR) dispersed in PMMA denture base material has been investigated. PMMA matrix without filler was prepared from PMMA powder with 0.5% benzoyl peroxide (PBO) as the control material. The similar PMMA matrix was mixed with Al<sub>2</sub>O<sub>3</sub>/Y-TSZ (1:1) together with NBR particles as the reinforcement. The amount of NBR was fixed at 7.5<!--> <!-->wt %, however, Al<sub>2</sub>O<sub>3</sub>/Y-TSZ varied from 1 to 10<!--> <!-->wt %, respectively. Samples with 4<!--> <!-->mm thickness for each composition were irradiated using 60 KV, 10<!--> <!-->mA, 0.4 s to examine their radiopacity. This radiopacity was compared to radiopacity of aluminum plate which having the same thickness. The result shows that the radiopacity (i.e. the lower optical density the higher radiopacity) of reinforced PMMA matrix slightly increased from 1.40 to 1.05, respectively, with the increased of filler loading compared to unreinforced PMMA matrix.</p></div>","PeriodicalId":20431,"journal":{"name":"Procedia Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.proche.2016.03.065","citationCount":"8","resultStr":"{\"title\":\"Influence of Al2O3/ Y-TSZ Mixture as Filler Loading on the Radiopacity of PMMA Denture Base Composites\",\"authors\":\"A.O. Alhareb ,&nbsp;H.M. Akil ,&nbsp;Z.A. Ahmad\",\"doi\":\"10.1016/j.proche.2016.03.065\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The radiopacity of alumina/yttrium stabilizer zirconia (Al<sub>2</sub>O<sub>3</sub>/Y-TSZ) particles with nitrile butadiene rubber (NBR) dispersed in PMMA denture base material has been investigated. PMMA matrix without filler was prepared from PMMA powder with 0.5% benzoyl peroxide (PBO) as the control material. The similar PMMA matrix was mixed with Al<sub>2</sub>O<sub>3</sub>/Y-TSZ (1:1) together with NBR particles as the reinforcement. The amount of NBR was fixed at 7.5<!--> <!-->wt %, however, Al<sub>2</sub>O<sub>3</sub>/Y-TSZ varied from 1 to 10<!--> <!-->wt %, respectively. Samples with 4<!--> <!-->mm thickness for each composition were irradiated using 60 KV, 10<!--> <!-->mA, 0.4 s to examine their radiopacity. This radiopacity was compared to radiopacity of aluminum plate which having the same thickness. The result shows that the radiopacity (i.e. the lower optical density the higher radiopacity) of reinforced PMMA matrix slightly increased from 1.40 to 1.05, respectively, with the increased of filler loading compared to unreinforced PMMA matrix.</p></div>\",\"PeriodicalId\":20431,\"journal\":{\"name\":\"Procedia Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.proche.2016.03.065\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Procedia Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S187661961600111X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Procedia Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S187661961600111X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

研究了氧化铝/钇稳定剂氧化锆(Al2O3/Y-TSZ)颗粒与丁腈橡胶(NBR)分散在PMMA义齿基托材料中的放射性。以0.5%过氧化苯甲酰(PBO)为对照材料,以PMMA粉末为原料制备无填料PMMA基体。将类似的PMMA基体与Al2O3/Y-TSZ(1:1)混合,并与NBR颗粒作为增强剂。NBR的添加量固定在7.5%,而Al2O3/Y-TSZ的添加量分别在1 ~ 10 wt %之间变化。每种成分的样品厚度为4 mm,用60 KV, 10 mA, 0.4 s照射,检查其放射不透性。并将其与厚度相同的铝板进行了对比。结果表明:与未增强PMMA相比,增强PMMA基体的射线不透明度(即光密度越低,射线不透明度越高)随填料填充量的增加而略有增加,分别从1.40增加到1.05;
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of Al2O3/ Y-TSZ Mixture as Filler Loading on the Radiopacity of PMMA Denture Base Composites

The radiopacity of alumina/yttrium stabilizer zirconia (Al2O3/Y-TSZ) particles with nitrile butadiene rubber (NBR) dispersed in PMMA denture base material has been investigated. PMMA matrix without filler was prepared from PMMA powder with 0.5% benzoyl peroxide (PBO) as the control material. The similar PMMA matrix was mixed with Al2O3/Y-TSZ (1:1) together with NBR particles as the reinforcement. The amount of NBR was fixed at 7.5 wt %, however, Al2O3/Y-TSZ varied from 1 to 10 wt %, respectively. Samples with 4 mm thickness for each composition were irradiated using 60 KV, 10 mA, 0.4 s to examine their radiopacity. This radiopacity was compared to radiopacity of aluminum plate which having the same thickness. The result shows that the radiopacity (i.e. the lower optical density the higher radiopacity) of reinforced PMMA matrix slightly increased from 1.40 to 1.05, respectively, with the increased of filler loading compared to unreinforced PMMA matrix.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信