基于PSH边带的断杆振动瞬态检测

V. Climente-Alarcón, J. Antonino-Daviu, F. Vedreno-Santos, R. Puche-Panadero
{"title":"基于PSH边带的断杆振动瞬态检测","authors":"V. Climente-Alarcón, J. Antonino-Daviu, F. Vedreno-Santos, R. Puche-Panadero","doi":"10.1109/ICELMACH.2012.6350238","DOIUrl":null,"url":null,"abstract":"In recent years, the study of transients of induction motors for diagnosis purposes has gained strength in order to overcome some inherent problems of the classical diagnosis of such machines, which uses Fourier analysis of steady-state quantities. Novel time-frequency techniques have been applied to these transient quantities, in order to detect the characteristic evolutions of fault-related harmonic components. The detection of these patterns, which are usually specific for each type of fault, enables reliable diagnostic of the corresponding failures. In this context, most of the works hitherto developed have been based on analysis of currents. However, in some applications vibration measurements are also available. The goal of this work is to validate the applicability of this transient-based diagnosis framework to vibration measurements. A specific time-frequency decomposition tool, the Wigner-Ville Distribution, is proposed. Experimental results prove the ability of the approach to complement the information obtained from the current analysis.","PeriodicalId":6309,"journal":{"name":"2012 XXth International Conference on Electrical Machines","volume":"13 1","pages":"2517-2521"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Vibration transient detection of broken bars by PSH sidebands\",\"authors\":\"V. Climente-Alarcón, J. Antonino-Daviu, F. Vedreno-Santos, R. Puche-Panadero\",\"doi\":\"10.1109/ICELMACH.2012.6350238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, the study of transients of induction motors for diagnosis purposes has gained strength in order to overcome some inherent problems of the classical diagnosis of such machines, which uses Fourier analysis of steady-state quantities. Novel time-frequency techniques have been applied to these transient quantities, in order to detect the characteristic evolutions of fault-related harmonic components. The detection of these patterns, which are usually specific for each type of fault, enables reliable diagnostic of the corresponding failures. In this context, most of the works hitherto developed have been based on analysis of currents. However, in some applications vibration measurements are also available. The goal of this work is to validate the applicability of this transient-based diagnosis framework to vibration measurements. A specific time-frequency decomposition tool, the Wigner-Ville Distribution, is proposed. Experimental results prove the ability of the approach to complement the information obtained from the current analysis.\",\"PeriodicalId\":6309,\"journal\":{\"name\":\"2012 XXth International Conference on Electrical Machines\",\"volume\":\"13 1\",\"pages\":\"2517-2521\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 XXth International Conference on Electrical Machines\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2012.6350238\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 XXth International Conference on Electrical Machines","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2012.6350238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

近年来,为了克服传统的用稳态量的傅立叶分析来诊断异步电机的固有问题,对异步电机暂态的研究得到了加强。新的时频技术已被应用于这些暂态量,以检测故障相关谐波分量的特征演变。这些模式的检测通常是针对每种类型的故障的,因此可以对相应的故障进行可靠的诊断。在这种背景下,迄今为止开发的大多数作品都是基于对电流的分析。然而,在某些应用中,振动测量也是可用的。这项工作的目的是验证这种基于瞬态的诊断框架对振动测量的适用性。提出了一种特殊的时频分解工具——Wigner-Ville分布。实验结果证明了该方法能够对现有分析结果进行补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Vibration transient detection of broken bars by PSH sidebands
In recent years, the study of transients of induction motors for diagnosis purposes has gained strength in order to overcome some inherent problems of the classical diagnosis of such machines, which uses Fourier analysis of steady-state quantities. Novel time-frequency techniques have been applied to these transient quantities, in order to detect the characteristic evolutions of fault-related harmonic components. The detection of these patterns, which are usually specific for each type of fault, enables reliable diagnostic of the corresponding failures. In this context, most of the works hitherto developed have been based on analysis of currents. However, in some applications vibration measurements are also available. The goal of this work is to validate the applicability of this transient-based diagnosis framework to vibration measurements. A specific time-frequency decomposition tool, the Wigner-Ville Distribution, is proposed. Experimental results prove the ability of the approach to complement the information obtained from the current analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信