高压直流线路6脉冲整流器的建模与分析

B. Madhu, M. Dinesh
{"title":"高压直流线路6脉冲整流器的建模与分析","authors":"B. Madhu, M. Dinesh","doi":"10.1109/ICPACE.2015.7274971","DOIUrl":null,"url":null,"abstract":"This paper presents miniature hardware model of 6 pulse controlled rectifier circuit for a monopolar HVDC link. The Controlled rectifier is interfaced with PIC (16F72) microcontroller for generating various firing angles. The results of output voltage are recorded using digital oscilloscope and are compared with the theoretical values at different firing angles. Performance analysis parameters such as voltage ripple, ripple percentage, harmonics with and without low pass filter for R and RL load is obtained by varying the firing angle. Results show that the ripple factor and ripple percentage has drastically reduced with the addition of the low pass filter and also smoothens the DC output voltage which were observed in digital oscilloscope. There has been a reduction of 92% ripple for R load and 60% for RL load (for firing angle α= 90°).","PeriodicalId":6644,"journal":{"name":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","volume":"98 1","pages":"350-354"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Modeling and analysis of 6 pulse rectifier used in HVDC link\",\"authors\":\"B. Madhu, M. Dinesh\",\"doi\":\"10.1109/ICPACE.2015.7274971\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents miniature hardware model of 6 pulse controlled rectifier circuit for a monopolar HVDC link. The Controlled rectifier is interfaced with PIC (16F72) microcontroller for generating various firing angles. The results of output voltage are recorded using digital oscilloscope and are compared with the theoretical values at different firing angles. Performance analysis parameters such as voltage ripple, ripple percentage, harmonics with and without low pass filter for R and RL load is obtained by varying the firing angle. Results show that the ripple factor and ripple percentage has drastically reduced with the addition of the low pass filter and also smoothens the DC output voltage which were observed in digital oscilloscope. There has been a reduction of 92% ripple for R load and 60% for RL load (for firing angle α= 90°).\",\"PeriodicalId\":6644,\"journal\":{\"name\":\"2015 International Conference on Power and Advanced Control Engineering (ICPACE)\",\"volume\":\"98 1\",\"pages\":\"350-354\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Power and Advanced Control Engineering (ICPACE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPACE.2015.7274971\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPACE.2015.7274971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文介绍了单极直流线路6脉冲控制整流电路的微型硬件模型。可控整流器与PIC (16F72)微控制器接口,用于产生各种发射角度。用数字示波器记录了输出电压,并与不同发射角度下的理论值进行了比较。通过改变发射角,获得了R和RL负载下电压纹波、纹波百分比、带低通滤波器和不带低通滤波器的谐波等性能分析参数。结果表明,低通滤波器的加入大大降低了纹波因子和纹波百分比,并使数字示波器中观察到的直流输出电压平滑。R负载(发射角α= 90°)纹波减小92%,RL负载(发射角α= 90°)纹波减小60%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modeling and analysis of 6 pulse rectifier used in HVDC link
This paper presents miniature hardware model of 6 pulse controlled rectifier circuit for a monopolar HVDC link. The Controlled rectifier is interfaced with PIC (16F72) microcontroller for generating various firing angles. The results of output voltage are recorded using digital oscilloscope and are compared with the theoretical values at different firing angles. Performance analysis parameters such as voltage ripple, ripple percentage, harmonics with and without low pass filter for R and RL load is obtained by varying the firing angle. Results show that the ripple factor and ripple percentage has drastically reduced with the addition of the low pass filter and also smoothens the DC output voltage which were observed in digital oscilloscope. There has been a reduction of 92% ripple for R load and 60% for RL load (for firing angle α= 90°).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信