{"title":"x射线粉末衍射:为什么不使用CuKβ辐射?","authors":"H. Otto","doi":"10.4236/jasmi.2018.83004","DOIUrl":null,"url":null,"abstract":"CuKβ radiation with a wavelength of λ = 1.3923 ? is recommended for crystal structure determination from X-ray powder diffraction using the Rietfeld method. A highly sensitive image plate detector is able to collect enough intensity to record a brilliant X-ray powder pattern in a reasonable time, compared to CuKα1 radiation used today. Especially atomic displacement coefficients could be determined more precisely with the much greater number of reflections recorded. A double-radius Guinier camera attached to a micro-focus rotating anode tube ensures increased brilliance besides high resolution. A simple construction specification is presented to make smart cylindrically bent Ge(111) or Si(111) X-ray monochromators that deliver focused CuKβ radiation. The highly linear response of image plate detectors allows removing of fluorescence radiation simply as background of the pattern. The proposed equipment is a cost-efficient alternative to a liquid gallium-metal-jet X-ray source with maximum power load and a similar wavelength of λ(GaKα1) = 1.34013 ?.","PeriodicalId":14932,"journal":{"name":"Journal of Analytical Sciences, Methods and Instrumentation","volume":"4 1","pages":"37-47"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"X-Ray Powder Diffraction: Why Not Use CuKβ Radiation?\",\"authors\":\"H. Otto\",\"doi\":\"10.4236/jasmi.2018.83004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"CuKβ radiation with a wavelength of λ = 1.3923 ? is recommended for crystal structure determination from X-ray powder diffraction using the Rietfeld method. A highly sensitive image plate detector is able to collect enough intensity to record a brilliant X-ray powder pattern in a reasonable time, compared to CuKα1 radiation used today. Especially atomic displacement coefficients could be determined more precisely with the much greater number of reflections recorded. A double-radius Guinier camera attached to a micro-focus rotating anode tube ensures increased brilliance besides high resolution. A simple construction specification is presented to make smart cylindrically bent Ge(111) or Si(111) X-ray monochromators that deliver focused CuKβ radiation. The highly linear response of image plate detectors allows removing of fluorescence radiation simply as background of the pattern. The proposed equipment is a cost-efficient alternative to a liquid gallium-metal-jet X-ray source with maximum power load and a similar wavelength of λ(GaKα1) = 1.34013 ?.\",\"PeriodicalId\":14932,\"journal\":{\"name\":\"Journal of Analytical Sciences, Methods and Instrumentation\",\"volume\":\"4 1\",\"pages\":\"37-47\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Sciences, Methods and Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4236/jasmi.2018.83004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Sciences, Methods and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/jasmi.2018.83004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
X-Ray Powder Diffraction: Why Not Use CuKβ Radiation?
CuKβ radiation with a wavelength of λ = 1.3923 ? is recommended for crystal structure determination from X-ray powder diffraction using the Rietfeld method. A highly sensitive image plate detector is able to collect enough intensity to record a brilliant X-ray powder pattern in a reasonable time, compared to CuKα1 radiation used today. Especially atomic displacement coefficients could be determined more precisely with the much greater number of reflections recorded. A double-radius Guinier camera attached to a micro-focus rotating anode tube ensures increased brilliance besides high resolution. A simple construction specification is presented to make smart cylindrically bent Ge(111) or Si(111) X-ray monochromators that deliver focused CuKβ radiation. The highly linear response of image plate detectors allows removing of fluorescence radiation simply as background of the pattern. The proposed equipment is a cost-efficient alternative to a liquid gallium-metal-jet X-ray source with maximum power load and a similar wavelength of λ(GaKα1) = 1.34013 ?.