生物人工心脏瓣膜台架耐久性的验证

S. Lieber
{"title":"生物人工心脏瓣膜台架耐久性的验证","authors":"S. Lieber","doi":"10.1115/imece2001/bed-23111","DOIUrl":null,"url":null,"abstract":"\n The number of heart valve replacements is increasing in the United States and worldwide due to aging of the population. This situation requires bioprosthetic heart valves with higher durability to reduce the rate of reoperation and the need for anticoagulation. However, introducing any improvement in the design of a heart valve requires ten years of validation in a clinical setup. A validated in-vitro fatigue testing system would significantly accelerate these innovations. The main objective of the proposed research is to:\n • Determine the dynamics of flow patterns and stresses in the vicinity of a bioprosthetic heart valve under pulsatile flow conditions.\n • Use the flow pattern information to validate an in-vitro fatigue testing system under physiological and accelerated conditions.","PeriodicalId":7238,"journal":{"name":"Advances in Bioengineering","volume":"16 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2001-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of Bench Durability of Bioprosthetic Heart Valves\",\"authors\":\"S. Lieber\",\"doi\":\"10.1115/imece2001/bed-23111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The number of heart valve replacements is increasing in the United States and worldwide due to aging of the population. This situation requires bioprosthetic heart valves with higher durability to reduce the rate of reoperation and the need for anticoagulation. However, introducing any improvement in the design of a heart valve requires ten years of validation in a clinical setup. A validated in-vitro fatigue testing system would significantly accelerate these innovations. The main objective of the proposed research is to:\\n • Determine the dynamics of flow patterns and stresses in the vicinity of a bioprosthetic heart valve under pulsatile flow conditions.\\n • Use the flow pattern information to validate an in-vitro fatigue testing system under physiological and accelerated conditions.\",\"PeriodicalId\":7238,\"journal\":{\"name\":\"Advances in Bioengineering\",\"volume\":\"16 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Bioengineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/imece2001/bed-23111\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Bioengineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2001/bed-23111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于人口老龄化,在美国和世界范围内,心脏瓣膜置换术的数量正在增加。这种情况需要具有更高耐久性的生物人工心脏瓣膜,以减少再手术率和抗凝的需要。然而,心脏瓣膜设计的任何改进都需要10年的临床验证。一个经过验证的体外疲劳测试系统将大大加速这些创新。拟议研究的主要目的是:•确定脉动流条件下生物假体心脏瓣膜附近的流动模式和应力的动态。•在生理和加速条件下,使用流型信息验证体外疲劳测试系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of Bench Durability of Bioprosthetic Heart Valves
The number of heart valve replacements is increasing in the United States and worldwide due to aging of the population. This situation requires bioprosthetic heart valves with higher durability to reduce the rate of reoperation and the need for anticoagulation. However, introducing any improvement in the design of a heart valve requires ten years of validation in a clinical setup. A validated in-vitro fatigue testing system would significantly accelerate these innovations. The main objective of the proposed research is to: • Determine the dynamics of flow patterns and stresses in the vicinity of a bioprosthetic heart valve under pulsatile flow conditions. • Use the flow pattern information to validate an in-vitro fatigue testing system under physiological and accelerated conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信