离子对高效液相色谱法同时测定兔血浆和红细胞中外源性磷酸肌酸及其代谢产物肌酸和相关ATP:应用于药动学研究

Li Lv, Heng Xi, G. Han
{"title":"离子对高效液相色谱法同时测定兔血浆和红细胞中外源性磷酸肌酸及其代谢产物肌酸和相关ATP:应用于药动学研究","authors":"Li Lv, Heng Xi, G. Han","doi":"10.4236/JASMI.2013.33A003","DOIUrl":null,"url":null,"abstract":"A specific, precise and accurate \nion-pair HPLC-UV method has been developed and validated for simultaneous determination \nof phosphocreatine (PCr), and its metabolite creatine (Cr) as well as related \nATP in plasma and red blood cell (RBC) of rabbits. After addition of TMP as IS, \nthe samples were deproteinized with 6% PCA. The analytes were separated on a \nKromasil C18 column using a tertiary gradient mobile phase composed of buffer A \n(0.2% KH2PO4 + 0.08% tetrabutyl ammonium hydrogen \nsulphate, pH 3.0), buffer B (buffer A adjusted to pH 7.5 with 1 mol/L NaOH) and \nMeOH. Detection wavelengths were set at 210 nm for PCr and Cr and 260 nm for \nATP and TMP. Some blank samples were initially run for baseline subtraction. The linear \ndetection responses were obtained for PCr concentration over a range of 10 - 7500 mg/ml (plasma) and 5 - 2500 mg/ml (RBC) and for both Cr and ATP \nconcentrations of 10 - 1500 mg/ml (plasma) and 5 - 750 mg/ml (RBC) (r > 0.99). The QC samples of 3 analytes \nshowed intra-day and inter-day precisions (RSD) of - 107%. The method was successfully used to simultaneously determine plasma \nand RBC concentrations of the 3 analytes and to study pharmacokinetics after iv \nadministration of PCr to rabbits.","PeriodicalId":14932,"journal":{"name":"Journal of Analytical Sciences, Methods and Instrumentation","volume":"39 1","pages":"17-23"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"An Ion-Pair HPLC Method for Simultaneous Determination of Exogenous Phosphocreatine and Its Metabolite Creatine and Related ATP in Rabbit Plasma and RBC: Application to a Pharmacokinetic Study\",\"authors\":\"Li Lv, Heng Xi, G. Han\",\"doi\":\"10.4236/JASMI.2013.33A003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A specific, precise and accurate \\nion-pair HPLC-UV method has been developed and validated for simultaneous determination \\nof phosphocreatine (PCr), and its metabolite creatine (Cr) as well as related \\nATP in plasma and red blood cell (RBC) of rabbits. After addition of TMP as IS, \\nthe samples were deproteinized with 6% PCA. The analytes were separated on a \\nKromasil C18 column using a tertiary gradient mobile phase composed of buffer A \\n(0.2% KH2PO4 + 0.08% tetrabutyl ammonium hydrogen \\nsulphate, pH 3.0), buffer B (buffer A adjusted to pH 7.5 with 1 mol/L NaOH) and \\nMeOH. Detection wavelengths were set at 210 nm for PCr and Cr and 260 nm for \\nATP and TMP. Some blank samples were initially run for baseline subtraction. The linear \\ndetection responses were obtained for PCr concentration over a range of 10 - 7500 mg/ml (plasma) and 5 - 2500 mg/ml (RBC) and for both Cr and ATP \\nconcentrations of 10 - 1500 mg/ml (plasma) and 5 - 750 mg/ml (RBC) (r > 0.99). The QC samples of 3 analytes \\nshowed intra-day and inter-day precisions (RSD) of - 107%. The method was successfully used to simultaneously determine plasma \\nand RBC concentrations of the 3 analytes and to study pharmacokinetics after iv \\nadministration of PCr to rabbits.\",\"PeriodicalId\":14932,\"journal\":{\"name\":\"Journal of Analytical Sciences, Methods and Instrumentation\",\"volume\":\"39 1\",\"pages\":\"17-23\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Sciences, Methods and Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4236/JASMI.2013.33A003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Sciences, Methods and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/JASMI.2013.33A003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

建立了一种特异、精确、准确的离子对HPLC-UV同时测定家兔血浆和红细胞中磷酸肌酸(PCr)及其代谢产物肌酸(Cr)及相关ATP的方法。加入TMP作为IS后,用6% PCA对样品进行脱蛋白处理。色谱柱为Kromasil C18,三级梯度流动相为缓冲液a (0.2% KH2PO4 + 0.08%四丁基硫酸氢铵,pH 3.0)、缓冲液B(缓冲液a以1 mol/L NaOH调至pH 7.5)和MeOH。PCr和Cr检测波长为210 nm, ATP和TMP检测波长为260 nm。一些空白样品最初用于基线减法。PCr浓度在10 ~ 7500 mg/ml(血浆)和5 ~ 2500 mg/ml(红细胞)范围内,Cr和ATP浓度在10 ~ 1500 mg/ml(血浆)和5 ~ 750 mg/ml(红细胞)范围内均具有线性检测(r > 0.99)。3种分析物的QC样品的日间和日间精密度(RSD)为- 107%。该方法成功地同时测定了3种分析物的血浆和红细胞浓度,并研究了兔静脉给药后的药代动力学。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Ion-Pair HPLC Method for Simultaneous Determination of Exogenous Phosphocreatine and Its Metabolite Creatine and Related ATP in Rabbit Plasma and RBC: Application to a Pharmacokinetic Study
A specific, precise and accurate ion-pair HPLC-UV method has been developed and validated for simultaneous determination of phosphocreatine (PCr), and its metabolite creatine (Cr) as well as related ATP in plasma and red blood cell (RBC) of rabbits. After addition of TMP as IS, the samples were deproteinized with 6% PCA. The analytes were separated on a Kromasil C18 column using a tertiary gradient mobile phase composed of buffer A (0.2% KH2PO4 + 0.08% tetrabutyl ammonium hydrogen sulphate, pH 3.0), buffer B (buffer A adjusted to pH 7.5 with 1 mol/L NaOH) and MeOH. Detection wavelengths were set at 210 nm for PCr and Cr and 260 nm for ATP and TMP. Some blank samples were initially run for baseline subtraction. The linear detection responses were obtained for PCr concentration over a range of 10 - 7500 mg/ml (plasma) and 5 - 2500 mg/ml (RBC) and for both Cr and ATP concentrations of 10 - 1500 mg/ml (plasma) and 5 - 750 mg/ml (RBC) (r > 0.99). The QC samples of 3 analytes showed intra-day and inter-day precisions (RSD) of - 107%. The method was successfully used to simultaneously determine plasma and RBC concentrations of the 3 analytes and to study pharmacokinetics after iv administration of PCr to rabbits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信