利用漏感屏蔽改善电力变压器性能

T. Strous, G. Simonelli
{"title":"利用漏感屏蔽改善电力变压器性能","authors":"T. Strous, G. Simonelli","doi":"10.1109/ESPC.2019.8932074","DOIUrl":null,"url":null,"abstract":"This paper presents a novel technique to reduce the leakage inductance in transformers for switch mode power supplies. By introducing the leakage inductance shield, that reduces the leakage flux by means of Eddy current shielding, the leakage inductance is reduced by almost 15 % in a transformer for a 100 W, 100 kHz flyback converter. Analysis showed that this reduction in leakage flux is insufficient to fully mitigate the large voltage spikes and ringing in the circuits, caused by the leakage inductance. However, a small improvement in efficiency of a flyback converter can be achieved. It is concluded that the leakage inductance shield is simple to implement and can effectively decrease transformer leakage inductance, additional benefits to reduced electromagnetic interference can be expected as well, but were not proven in this paper.","PeriodicalId":6734,"journal":{"name":"2019 European Space Power Conference (ESPC)","volume":"35 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Improved Power Transformer Performance using Leakage Inductance Shielding\",\"authors\":\"T. Strous, G. Simonelli\",\"doi\":\"10.1109/ESPC.2019.8932074\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel technique to reduce the leakage inductance in transformers for switch mode power supplies. By introducing the leakage inductance shield, that reduces the leakage flux by means of Eddy current shielding, the leakage inductance is reduced by almost 15 % in a transformer for a 100 W, 100 kHz flyback converter. Analysis showed that this reduction in leakage flux is insufficient to fully mitigate the large voltage spikes and ringing in the circuits, caused by the leakage inductance. However, a small improvement in efficiency of a flyback converter can be achieved. It is concluded that the leakage inductance shield is simple to implement and can effectively decrease transformer leakage inductance, additional benefits to reduced electromagnetic interference can be expected as well, but were not proven in this paper.\",\"PeriodicalId\":6734,\"journal\":{\"name\":\"2019 European Space Power Conference (ESPC)\",\"volume\":\"35 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 European Space Power Conference (ESPC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESPC.2019.8932074\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 European Space Power Conference (ESPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESPC.2019.8932074","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种减小开关电源变压器漏感的新方法。在100w、100khz反激变换器中,通过引入漏电电感屏蔽,通过涡流屏蔽降低漏磁通,使变压器的漏电电感降低了近15%。分析表明,泄漏磁通的减少不足以完全缓解电路中由泄漏电感引起的大电压尖峰和振铃。然而,反激变换器的效率可以有一个小的提高。结果表明,漏感屏蔽结构设计简单,能有效降低变压器的漏感,对减少电磁干扰也有一定的好处,但本文未对其进行验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improved Power Transformer Performance using Leakage Inductance Shielding
This paper presents a novel technique to reduce the leakage inductance in transformers for switch mode power supplies. By introducing the leakage inductance shield, that reduces the leakage flux by means of Eddy current shielding, the leakage inductance is reduced by almost 15 % in a transformer for a 100 W, 100 kHz flyback converter. Analysis showed that this reduction in leakage flux is insufficient to fully mitigate the large voltage spikes and ringing in the circuits, caused by the leakage inductance. However, a small improvement in efficiency of a flyback converter can be achieved. It is concluded that the leakage inductance shield is simple to implement and can effectively decrease transformer leakage inductance, additional benefits to reduced electromagnetic interference can be expected as well, but were not proven in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信