N. R. Amalia, A. Hatta, S. Koentjoro, A. Nasution, I. Puspita
{"title":"用于同时测量智能床上心跳和呼吸速率的光纤传感器","authors":"N. R. Amalia, A. Hatta, S. Koentjoro, A. Nasution, I. Puspita","doi":"10.1109/ICP46580.2020.9206491","DOIUrl":null,"url":null,"abstract":"Heart and breath rate are fundamental vital signs used for early detection in cardiac events. In this work, a sensor based on singlemode-multimode-singlemode (SMS) fiber structure was designed, fabricated, and tested for simultaneous measurement of heart and breath rate on a bed. A signal processing was used for obtaining the heart rate from the output signal of SMS fiber structure. In order to reduce noise in the heart rate signal, a Butterworth filter was employed. The results show that the proposed SMS fiber structure as a sensor has a relative error of 11% and 6% for measuring the heart and breath rate, respectively. The SMS fiber sensor gives a potency to measure the heart and breath rate simultaneously on a smart bed and suitable to be used in home and hospital.","PeriodicalId":6758,"journal":{"name":"2020 IEEE 8th International Conference on Photonics (ICP)","volume":"60 1","pages":"68-69"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fiber Sensor for Simultaneous Measurement of Heart and Breath Rate on SmartBed\",\"authors\":\"N. R. Amalia, A. Hatta, S. Koentjoro, A. Nasution, I. Puspita\",\"doi\":\"10.1109/ICP46580.2020.9206491\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Heart and breath rate are fundamental vital signs used for early detection in cardiac events. In this work, a sensor based on singlemode-multimode-singlemode (SMS) fiber structure was designed, fabricated, and tested for simultaneous measurement of heart and breath rate on a bed. A signal processing was used for obtaining the heart rate from the output signal of SMS fiber structure. In order to reduce noise in the heart rate signal, a Butterworth filter was employed. The results show that the proposed SMS fiber structure as a sensor has a relative error of 11% and 6% for measuring the heart and breath rate, respectively. The SMS fiber sensor gives a potency to measure the heart and breath rate simultaneously on a smart bed and suitable to be used in home and hospital.\",\"PeriodicalId\":6758,\"journal\":{\"name\":\"2020 IEEE 8th International Conference on Photonics (ICP)\",\"volume\":\"60 1\",\"pages\":\"68-69\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 8th International Conference on Photonics (ICP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICP46580.2020.9206491\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 8th International Conference on Photonics (ICP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICP46580.2020.9206491","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fiber Sensor for Simultaneous Measurement of Heart and Breath Rate on SmartBed
Heart and breath rate are fundamental vital signs used for early detection in cardiac events. In this work, a sensor based on singlemode-multimode-singlemode (SMS) fiber structure was designed, fabricated, and tested for simultaneous measurement of heart and breath rate on a bed. A signal processing was used for obtaining the heart rate from the output signal of SMS fiber structure. In order to reduce noise in the heart rate signal, a Butterworth filter was employed. The results show that the proposed SMS fiber structure as a sensor has a relative error of 11% and 6% for measuring the heart and breath rate, respectively. The SMS fiber sensor gives a potency to measure the heart and breath rate simultaneously on a smart bed and suitable to be used in home and hospital.