利用飞行时间-二次离子质谱法定量分析SiC中Al的深度分布

V. Smentkowski, S. Goswami
{"title":"利用飞行时间-二次离子质谱法定量分析SiC中Al的深度分布","authors":"V. Smentkowski, S. Goswami","doi":"10.1116/6.0000905","DOIUrl":null,"url":null,"abstract":"Historically, dynamic secondary ion mass spectroscopy (D-SIMS) has been used to quantitatively monitor the depth distribution of species present in low concentrations in samples/devices. We are not aware of any manuscript that describes the use of time of flight–secondary ion mass spectroscopy (ToF-SIMS) to perform quantitative analysis of aluminum present at low concentrations in silicon carbide (SiC) wafer substrates. In this paper, we will show that ToF-SIMS is able to replicate D-SIMS analysis. However, analysis at the lowest concentrations requires the collection of more spectral images at each depth. Tables of sputtering rates and sputtering yields, in addition to relative sensitivity factors are provided. We also highlight the benefits of ToF-SIMS analysis.","PeriodicalId":17571,"journal":{"name":"Journal of Vacuum Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Quantitative depth profiling of Al in SiC using time of flight–secondary ion mass spectroscopy\",\"authors\":\"V. Smentkowski, S. Goswami\",\"doi\":\"10.1116/6.0000905\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Historically, dynamic secondary ion mass spectroscopy (D-SIMS) has been used to quantitatively monitor the depth distribution of species present in low concentrations in samples/devices. We are not aware of any manuscript that describes the use of time of flight–secondary ion mass spectroscopy (ToF-SIMS) to perform quantitative analysis of aluminum present at low concentrations in silicon carbide (SiC) wafer substrates. In this paper, we will show that ToF-SIMS is able to replicate D-SIMS analysis. However, analysis at the lowest concentrations requires the collection of more spectral images at each depth. Tables of sputtering rates and sputtering yields, in addition to relative sensitivity factors are provided. We also highlight the benefits of ToF-SIMS analysis.\",\"PeriodicalId\":17571,\"journal\":{\"name\":\"Journal of Vacuum Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vacuum Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1116/6.0000905\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vacuum Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1116/6.0000905","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

历史上,动态二次离子质谱(D-SIMS)已被用于定量监测样品/设备中低浓度物种的深度分布。我们不知道有任何手稿描述了使用飞行时间二次离子质谱(ToF-SIMS)对存在于碳化硅(SiC)晶圆衬底中的低浓度铝进行定量分析。在本文中,我们将证明ToF-SIMS能够复制D-SIMS分析。然而,在最低浓度的分析需要在每个深度收集更多的光谱图像。此外,还提供了溅射速率和溅射收率表以及相对灵敏度因子。我们还强调了ToF-SIMS分析的好处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantitative depth profiling of Al in SiC using time of flight–secondary ion mass spectroscopy
Historically, dynamic secondary ion mass spectroscopy (D-SIMS) has been used to quantitatively monitor the depth distribution of species present in low concentrations in samples/devices. We are not aware of any manuscript that describes the use of time of flight–secondary ion mass spectroscopy (ToF-SIMS) to perform quantitative analysis of aluminum present at low concentrations in silicon carbide (SiC) wafer substrates. In this paper, we will show that ToF-SIMS is able to replicate D-SIMS analysis. However, analysis at the lowest concentrations requires the collection of more spectral images at each depth. Tables of sputtering rates and sputtering yields, in addition to relative sensitivity factors are provided. We also highlight the benefits of ToF-SIMS analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信