永磁同步发电机变速风力发电机组综合建模与分析

Z. Tasneem, M. Sheikh
{"title":"永磁同步发电机变速风力发电机组综合建模与分析","authors":"Z. Tasneem, M. Sheikh","doi":"10.1109/CEEE.2015.7428238","DOIUrl":null,"url":null,"abstract":"Various types of converter-inverter topologies have been used in recent times for wind farms. This paper presents some new converter-inverter methods applied in a wind farm consisting of Permanent Magnet Synchronous Generator (PMSG). Conventional 3-level converter-inverter responses have been compared with comparatively newer flying capacitor model and improved Z-source converter models. Simulation results show the effectiveness of the proposed control topology. In order to extract maximum power, and hence regulate the voltage and frequency under varying wind conditions, converter-inverter sets are associated with Maximum Power Point Tracking (MPPT) System. Simulations have been done by using the engineering software PSCAD/EMTDC. Real wind speed data have been considered for this study.","PeriodicalId":6490,"journal":{"name":"2015 International Conference on Electrical & Electronic Engineering (ICEEE)","volume":"1 1","pages":"133-136"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comprehensive modeling and analysis of Variable Speed Wind Turbine using Permanent Magnet Synchronous Generator\",\"authors\":\"Z. Tasneem, M. Sheikh\",\"doi\":\"10.1109/CEEE.2015.7428238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Various types of converter-inverter topologies have been used in recent times for wind farms. This paper presents some new converter-inverter methods applied in a wind farm consisting of Permanent Magnet Synchronous Generator (PMSG). Conventional 3-level converter-inverter responses have been compared with comparatively newer flying capacitor model and improved Z-source converter models. Simulation results show the effectiveness of the proposed control topology. In order to extract maximum power, and hence regulate the voltage and frequency under varying wind conditions, converter-inverter sets are associated with Maximum Power Point Tracking (MPPT) System. Simulations have been done by using the engineering software PSCAD/EMTDC. Real wind speed data have been considered for this study.\",\"PeriodicalId\":6490,\"journal\":{\"name\":\"2015 International Conference on Electrical & Electronic Engineering (ICEEE)\",\"volume\":\"1 1\",\"pages\":\"133-136\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Electrical & Electronic Engineering (ICEEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEEE.2015.7428238\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Electrical & Electronic Engineering (ICEEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEE.2015.7428238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

近年来,各种类型的变换器-逆变器拓扑结构已被用于风力发电场。本文介绍了在由永磁同步发电机组成的风电场中应用的几种新的变换器-逆变器方法。将传统的3电平变换器-逆变器响应与较新的飞行电容模型和改进的z源变换器模型进行了比较。仿真结果表明了所提控制拓扑的有效性。为了提取最大功率,从而在不同风力条件下调节电压和频率,变流器-逆变器机组与最大功率点跟踪(MPPT)系统相关联。利用工程软件PSCAD/EMTDC进行了仿真。本研究考虑了实际风速数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comprehensive modeling and analysis of Variable Speed Wind Turbine using Permanent Magnet Synchronous Generator
Various types of converter-inverter topologies have been used in recent times for wind farms. This paper presents some new converter-inverter methods applied in a wind farm consisting of Permanent Magnet Synchronous Generator (PMSG). Conventional 3-level converter-inverter responses have been compared with comparatively newer flying capacitor model and improved Z-source converter models. Simulation results show the effectiveness of the proposed control topology. In order to extract maximum power, and hence regulate the voltage and frequency under varying wind conditions, converter-inverter sets are associated with Maximum Power Point Tracking (MPPT) System. Simulations have been done by using the engineering software PSCAD/EMTDC. Real wind speed data have been considered for this study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信