{"title":"实现CISPR 16-1的多分辨率时域电磁干扰测量系统的研制","authors":"S. Braun, M. Aidam, P. Russer","doi":"10.1109/ISEMC.2005.1513545","DOIUrl":null,"url":null,"abstract":"Measurement systems, that allow to measure within short measurement time electromagnetic interference (EMI), will reduce the costs for compliance tests. A time-domain EMI (TDEMI) measurement system can reduce the measurement time by several orders of magnitude. In order to have the permission to use a time-domain EMI measurement system for compliance measurements it has to fulfill the CISPR 16-1 (1999) completely. In the following the requirements given by CISPR 16-1 are applied to the TDEMI measurement system. The characteristics of the TDEMI measurement system are compared with the rules of CISPR 16-1. A multiresolution TDEMI (MRTDEMI) measurement system that uses several analog-to-digital converters (ADCs) is presented. With such a system the signal-to-noise ratio (SNR) is enhanced. Measurements have been carried out in the frequency range 30 MHz - 1 GHz. It is shown, that almost all requirements are fulfill led by the MRTDEMI measurement system.","PeriodicalId":6459,"journal":{"name":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","volume":"150 1","pages":"388-393 Vol. 2"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":"{\"title\":\"Development of a multiresolution time domain EMI measurement system that fulfills CISPR 16-1\",\"authors\":\"S. Braun, M. Aidam, P. Russer\",\"doi\":\"10.1109/ISEMC.2005.1513545\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurement systems, that allow to measure within short measurement time electromagnetic interference (EMI), will reduce the costs for compliance tests. A time-domain EMI (TDEMI) measurement system can reduce the measurement time by several orders of magnitude. In order to have the permission to use a time-domain EMI measurement system for compliance measurements it has to fulfill the CISPR 16-1 (1999) completely. In the following the requirements given by CISPR 16-1 are applied to the TDEMI measurement system. The characteristics of the TDEMI measurement system are compared with the rules of CISPR 16-1. A multiresolution TDEMI (MRTDEMI) measurement system that uses several analog-to-digital converters (ADCs) is presented. With such a system the signal-to-noise ratio (SNR) is enhanced. Measurements have been carried out in the frequency range 30 MHz - 1 GHz. It is shown, that almost all requirements are fulfill led by the MRTDEMI measurement system.\",\"PeriodicalId\":6459,\"journal\":{\"name\":\"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.\",\"volume\":\"150 1\",\"pages\":\"388-393 Vol. 2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"31\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2005.1513545\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2005.1513545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of a multiresolution time domain EMI measurement system that fulfills CISPR 16-1
Measurement systems, that allow to measure within short measurement time electromagnetic interference (EMI), will reduce the costs for compliance tests. A time-domain EMI (TDEMI) measurement system can reduce the measurement time by several orders of magnitude. In order to have the permission to use a time-domain EMI measurement system for compliance measurements it has to fulfill the CISPR 16-1 (1999) completely. In the following the requirements given by CISPR 16-1 are applied to the TDEMI measurement system. The characteristics of the TDEMI measurement system are compared with the rules of CISPR 16-1. A multiresolution TDEMI (MRTDEMI) measurement system that uses several analog-to-digital converters (ADCs) is presented. With such a system the signal-to-noise ratio (SNR) is enhanced. Measurements have been carried out in the frequency range 30 MHz - 1 GHz. It is shown, that almost all requirements are fulfill led by the MRTDEMI measurement system.