{"title":"除颤器和起搏器电极之间的阻抗和通信记录","authors":"A. Jarløv, A. Jarløv, T. Jensen","doi":"10.4018/IJBCE.2019070103","DOIUrl":null,"url":null,"abstract":"External defibrillation involves short electric shocks of several thousand volts applied to the chest of patients suffering from heart stop. The shock coordinates disorganized muscle fibers of the heart which then can resume normal activity. Implanted pacemakers monitor the natural electrical activity of the heart via electrodes mounted permanently on the inside of the heart. If this activity is insufficient, the pacemaker stimulates the heart muscle by applying a short electrical impulse of a few volts. During the period of defibrillation, voltage differences arise simultaneously between various locations of the body preventing recordings of the heart's natural activity. In order to quantify parameters determining voltage and current in a conductive medium or in a myocardium when defibrillator and pacemaker electrodes are present simultaneously, impedances between electrodes positioned on conductive materials were recorded in laboratory set ups, and the methods were tested using a porcine heart in vitro.","PeriodicalId":73426,"journal":{"name":"International journal of biomedical engineering and clinical science","volume":"198 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Recordings of Impedance and Communication Between Defibrillator and Pacemaker Electrodes\",\"authors\":\"A. Jarløv, A. Jarløv, T. Jensen\",\"doi\":\"10.4018/IJBCE.2019070103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"External defibrillation involves short electric shocks of several thousand volts applied to the chest of patients suffering from heart stop. The shock coordinates disorganized muscle fibers of the heart which then can resume normal activity. Implanted pacemakers monitor the natural electrical activity of the heart via electrodes mounted permanently on the inside of the heart. If this activity is insufficient, the pacemaker stimulates the heart muscle by applying a short electrical impulse of a few volts. During the period of defibrillation, voltage differences arise simultaneously between various locations of the body preventing recordings of the heart's natural activity. In order to quantify parameters determining voltage and current in a conductive medium or in a myocardium when defibrillator and pacemaker electrodes are present simultaneously, impedances between electrodes positioned on conductive materials were recorded in laboratory set ups, and the methods were tested using a porcine heart in vitro.\",\"PeriodicalId\":73426,\"journal\":{\"name\":\"International journal of biomedical engineering and clinical science\",\"volume\":\"198 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of biomedical engineering and clinical science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4018/IJBCE.2019070103\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of biomedical engineering and clinical science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4018/IJBCE.2019070103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

体外除颤包括对心脏骤停患者的胸部施加数千伏特的短电击。电击会协调心脏紊乱的肌肉纤维,使其恢复正常活动。植入的起搏器通过永久安装在心脏内部的电极监测心脏的自然电活动。如果这种活动不足,起搏器通过施加几伏特的短电脉冲来刺激心肌。在除颤期间,身体不同部位之间同时产生电压差异,从而无法记录心脏的自然活动。为了量化在除颤器和起搏器电极同时存在时导电介质或心肌中确定电压和电流的参数,在实验室设置中记录了放置在导电材料上的电极之间的阻抗,并使用体外猪心脏测试了这些方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Recordings of Impedance and Communication Between Defibrillator and Pacemaker Electrodes
External defibrillation involves short electric shocks of several thousand volts applied to the chest of patients suffering from heart stop. The shock coordinates disorganized muscle fibers of the heart which then can resume normal activity. Implanted pacemakers monitor the natural electrical activity of the heart via electrodes mounted permanently on the inside of the heart. If this activity is insufficient, the pacemaker stimulates the heart muscle by applying a short electrical impulse of a few volts. During the period of defibrillation, voltage differences arise simultaneously between various locations of the body preventing recordings of the heart's natural activity. In order to quantify parameters determining voltage and current in a conductive medium or in a myocardium when defibrillator and pacemaker electrodes are present simultaneously, impedances between electrodes positioned on conductive materials were recorded in laboratory set ups, and the methods were tested using a porcine heart in vitro.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信