本征水和离子渗透对聚对二甲苯C薄膜介电性能的影响

IF 3 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Jacob T. Pawlik;Nikolas D. Barrera;Eugene J. Yoon;James C. Booth;Christian J. Long;Nathan D. Orloff;Ellis Meng;Angela C. Stelson
{"title":"本征水和离子渗透对聚对二甲苯C薄膜介电性能的影响","authors":"Jacob T. Pawlik;Nikolas D. Barrera;Eugene J. Yoon;James C. Booth;Christian J. Long;Nathan D. Orloff;Ellis Meng;Angela C. Stelson","doi":"10.1109/JERM.2023.3285049","DOIUrl":null,"url":null,"abstract":"Parylene C is a widely used dielectric barrier in implantable medical devices because it conforms well to surfaces and insulates against biological environments. However, multiple studies have shown that moisture can intrude into Parylene C films through defects and intrinsic diffusion, leading to delamination and device failure. While many studies have tested device integrity in vitro, few have isolated the influence of specific degradation mechanisms on device failure. Here, we use a broadband impedance technique called Microwave Microfluidic Spectroscopy (MMS) to measure fluid permeation in targeted regions of Parylene C films that are free of defects and have optimal adhesion to the substrate. We found no changes in the broadband S-parameters from 100 MHz–110 GHz for Parylene C coated coplanar waveguides soaked in water or phosphate buffered saline at 20 °C or 37 °C for two months. Furthermore, there was no delamination induced by fluid soaking. Our study helps to clear debate about the influence of water and ion diffusion on Parylene C device lifetime and inform better fabrication of Parylene C coatings for implantable devices.","PeriodicalId":29955,"journal":{"name":"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2023-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Influence of Intrinsic Water and Ion Permeation on the Dielectric Properties of Parylene C Films\",\"authors\":\"Jacob T. Pawlik;Nikolas D. Barrera;Eugene J. Yoon;James C. Booth;Christian J. Long;Nathan D. Orloff;Ellis Meng;Angela C. Stelson\",\"doi\":\"10.1109/JERM.2023.3285049\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Parylene C is a widely used dielectric barrier in implantable medical devices because it conforms well to surfaces and insulates against biological environments. However, multiple studies have shown that moisture can intrude into Parylene C films through defects and intrinsic diffusion, leading to delamination and device failure. While many studies have tested device integrity in vitro, few have isolated the influence of specific degradation mechanisms on device failure. Here, we use a broadband impedance technique called Microwave Microfluidic Spectroscopy (MMS) to measure fluid permeation in targeted regions of Parylene C films that are free of defects and have optimal adhesion to the substrate. We found no changes in the broadband S-parameters from 100 MHz–110 GHz for Parylene C coated coplanar waveguides soaked in water or phosphate buffered saline at 20 °C or 37 °C for two months. Furthermore, there was no delamination induced by fluid soaking. Our study helps to clear debate about the influence of water and ion diffusion on Parylene C device lifetime and inform better fabrication of Parylene C coatings for implantable devices.\",\"PeriodicalId\":29955,\"journal\":{\"name\":\"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2023-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10171807/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10171807/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

聚对二甲苯C是一种广泛应用于植入式医疗器械的介电屏障,因为它与表面很好地吻合,并且与生物环境绝缘。然而,多项研究表明,水分可以通过缺陷和本征扩散侵入聚对二甲苯薄膜,导致分层和器件失效。虽然许多研究在体外测试了设备的完整性,但很少有研究分离出特定降解机制对设备故障的影响。在这里,我们使用一种称为微波微流体光谱(MMS)的宽带阻抗技术来测量无缺陷且与衬底具有最佳粘附性的聚对二甲苯薄膜目标区域的流体渗透率。我们发现,在20°C或37°C的水或磷酸盐缓冲盐水中浸泡两个月的聚对二甲苯涂层共面波导的宽带s参数在100 MHz-110 GHz范围内没有变化。此外,液体浸泡没有引起分层。我们的研究有助于澄清关于水和离子扩散对聚对二甲苯器件寿命影响的争论,并为更好地制造用于植入器件的聚对二甲苯涂层提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Influence of Intrinsic Water and Ion Permeation on the Dielectric Properties of Parylene C Films
Parylene C is a widely used dielectric barrier in implantable medical devices because it conforms well to surfaces and insulates against biological environments. However, multiple studies have shown that moisture can intrude into Parylene C films through defects and intrinsic diffusion, leading to delamination and device failure. While many studies have tested device integrity in vitro, few have isolated the influence of specific degradation mechanisms on device failure. Here, we use a broadband impedance technique called Microwave Microfluidic Spectroscopy (MMS) to measure fluid permeation in targeted regions of Parylene C films that are free of defects and have optimal adhesion to the substrate. We found no changes in the broadband S-parameters from 100 MHz–110 GHz for Parylene C coated coplanar waveguides soaked in water or phosphate buffered saline at 20 °C or 37 °C for two months. Furthermore, there was no delamination induced by fluid soaking. Our study helps to clear debate about the influence of water and ion diffusion on Parylene C device lifetime and inform better fabrication of Parylene C coatings for implantable devices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.80
自引率
9.40%
发文量
58
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信