{"title":"胰胆管扩张患者三维双能CT胰胆管成像质量的评价:与传统单能CT的比较。","authors":"Bin Li, JianMing Ni, FangMing Chen, FengQi Lu, Lei Zhang, WenJuan Wu, ZhuiYang Zhang","doi":"10.1016/j.ejro.2023.100537","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>This study aimed to evaluate three-dimensional (3D) negative-contrast CT cholangiopancreatography (nCTCP) image quality using dual-energy CT (DECT) with iterative reconstruction (IR) technique in patients with pancreatobiliary dilatation compared with single-energy CT (SECT).</p></div><div><h3>Methods</h3><p>Of the patients, 67 and 56 underwent conventional SECT (SECT set) and DECT with IR technique (DECT set), respectively. All patients were retrospectively analyzed during the portal phase to compare objective image quality and other data including patient demographics, hepatic and pancreatic parenchymal enhancement, noise, and attenuation difference (AD) between dilated ducts and enhanced hepatic parenchyma, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and CT volume dose index (CTDI<sub>vol</sub>). Two radiologists used the five-point Likert scale to evaluate the subjective image quality of 3D nCTCP regarding image noise, sharpness of dilated ducts, and overall image quality. Statistical analyses used the Mann–Whitney <em>U</em> test.</p></div><div><h3>Results</h3><p>No significant difference in patient demographics in either CT set was showed during objective evaluation (<em>p</em> > 0.05). However, higher hepatic and pancreatic parenchymal enhancement, AD, SNR, and CNR and lower hepatic and pancreatic noise (<em>p</em> < 0.005) as well as CTDI<sub>vol</sub> (<em>p</em> = 0.005) on DECT than on SECT were observed. Higher mean grades on DECT than on SECT were showed for image noise (4.65 vs 3.92), sharpness of dilated ducts (4.52 vs 3.94), and overall image quality (4.45 vs 3.91; <em>p</em> < 0.001), respectively during subjective evaluation.</p></div><div><h3>Conclusion</h3><p>A higher overall image quality and lower radiation dose on 3D nCTCP can be obtained by DECT with IR technique than with conventional SECT in patients with pancreatobiliary dilatation.</p></div>","PeriodicalId":38076,"journal":{"name":"European Journal of Radiology Open","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2023-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628547/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT\",\"authors\":\"Bin Li, JianMing Ni, FangMing Chen, FengQi Lu, Lei Zhang, WenJuan Wu, ZhuiYang Zhang\",\"doi\":\"10.1016/j.ejro.2023.100537\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>This study aimed to evaluate three-dimensional (3D) negative-contrast CT cholangiopancreatography (nCTCP) image quality using dual-energy CT (DECT) with iterative reconstruction (IR) technique in patients with pancreatobiliary dilatation compared with single-energy CT (SECT).</p></div><div><h3>Methods</h3><p>Of the patients, 67 and 56 underwent conventional SECT (SECT set) and DECT with IR technique (DECT set), respectively. All patients were retrospectively analyzed during the portal phase to compare objective image quality and other data including patient demographics, hepatic and pancreatic parenchymal enhancement, noise, and attenuation difference (AD) between dilated ducts and enhanced hepatic parenchyma, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and CT volume dose index (CTDI<sub>vol</sub>). Two radiologists used the five-point Likert scale to evaluate the subjective image quality of 3D nCTCP regarding image noise, sharpness of dilated ducts, and overall image quality. Statistical analyses used the Mann–Whitney <em>U</em> test.</p></div><div><h3>Results</h3><p>No significant difference in patient demographics in either CT set was showed during objective evaluation (<em>p</em> > 0.05). However, higher hepatic and pancreatic parenchymal enhancement, AD, SNR, and CNR and lower hepatic and pancreatic noise (<em>p</em> < 0.005) as well as CTDI<sub>vol</sub> (<em>p</em> = 0.005) on DECT than on SECT were observed. Higher mean grades on DECT than on SECT were showed for image noise (4.65 vs 3.92), sharpness of dilated ducts (4.52 vs 3.94), and overall image quality (4.45 vs 3.91; <em>p</em> < 0.001), respectively during subjective evaluation.</p></div><div><h3>Conclusion</h3><p>A higher overall image quality and lower radiation dose on 3D nCTCP can be obtained by DECT with IR technique than with conventional SECT in patients with pancreatobiliary dilatation.</p></div>\",\"PeriodicalId\":38076,\"journal\":{\"name\":\"European Journal of Radiology Open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628547/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Radiology Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352047723000631\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Radiology Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352047723000631","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
摘要
目的:本研究旨在评估双能CT(DECT)与迭代重建(IR)技术在胰胆管扩张患者中的三维(3D)阴性对比CT胰胆管成像(nCTCP)图像质量,并与单能CT(SECT)进行比较,分别地在门静脉期对所有患者进行回顾性分析,以比较客观图像质量和其他数据,包括患者人口统计学、肝和胰腺实质增强、扩张导管和增强肝实质之间的噪声和衰减差异(AD)、信噪比(SNR)、对比噪声比(CNR)和CT体积剂量指数(CTDIvol)。两名放射科医生使用五点Likert量表评估3D nCTCP的主观图像质量,包括图像噪声、扩张导管的清晰度和整体图像质量。统计分析采用Mann-Whitney U检验。结果:在客观评估过程中,两组CT的患者人口统计数据均无显著差异(p>0.05)。然而,与SECT相比,DECT的肝和胰腺实质增强、AD、SNR和CNR更高,肝和胰腺噪声更低(p vol(p=0.005))。在图像噪声(4.65 vs 3.92)、扩张导管的清晰度(4.52 vs 3.94)和整体图像质量(4.45 vs 3.91)方面,DECT的平均等级高于SECT。
Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
Objective
This study aimed to evaluate three-dimensional (3D) negative-contrast CT cholangiopancreatography (nCTCP) image quality using dual-energy CT (DECT) with iterative reconstruction (IR) technique in patients with pancreatobiliary dilatation compared with single-energy CT (SECT).
Methods
Of the patients, 67 and 56 underwent conventional SECT (SECT set) and DECT with IR technique (DECT set), respectively. All patients were retrospectively analyzed during the portal phase to compare objective image quality and other data including patient demographics, hepatic and pancreatic parenchymal enhancement, noise, and attenuation difference (AD) between dilated ducts and enhanced hepatic parenchyma, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and CT volume dose index (CTDIvol). Two radiologists used the five-point Likert scale to evaluate the subjective image quality of 3D nCTCP regarding image noise, sharpness of dilated ducts, and overall image quality. Statistical analyses used the Mann–Whitney U test.
Results
No significant difference in patient demographics in either CT set was showed during objective evaluation (p > 0.05). However, higher hepatic and pancreatic parenchymal enhancement, AD, SNR, and CNR and lower hepatic and pancreatic noise (p < 0.005) as well as CTDIvol (p = 0.005) on DECT than on SECT were observed. Higher mean grades on DECT than on SECT were showed for image noise (4.65 vs 3.92), sharpness of dilated ducts (4.52 vs 3.94), and overall image quality (4.45 vs 3.91; p < 0.001), respectively during subjective evaluation.
Conclusion
A higher overall image quality and lower radiation dose on 3D nCTCP can be obtained by DECT with IR technique than with conventional SECT in patients with pancreatobiliary dilatation.