基于硅光电倍增管的PET和传统PET在小结构中生理FDG摄取的比较研究。

IF 2.5 4区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Annals of Nuclear Medicine Pub Date : 2024-02-01 Epub Date: 2023-11-09 DOI:10.1007/s12149-023-01884-3
Shiro Watanabe, Kenji Hirata, Keiichi Magota, Junki Takenaka, Naoto Wakabayashi, Daiki Shinyama, Koichi Yasuda, Akihiro Homma, Kohsuke Kudo
{"title":"基于硅光电倍增管的PET和传统PET在小结构中生理FDG摄取的比较研究。","authors":"Shiro Watanabe, Kenji Hirata, Keiichi Magota, Junki Takenaka, Naoto Wakabayashi, Daiki Shinyama, Koichi Yasuda, Akihiro Homma, Kohsuke Kudo","doi":"10.1007/s12149-023-01884-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Silicon photomultiplier-based positron emission tomography/computed tomography (SiPM-PET/CT) has the superior spatial resolution to conventional PET/CT (cPET/CT). This head-to-head comparison study compared the images of physiological <sup>18</sup>F-fluorodeoxyglucose (FDG) accumulation in small-volume structures between SiPM-PET/CT and cPET/CT in patients scanned with both modalities, and we investigated whether the thresholds that are reported to be useful for differentiating physiological accumulations from malignant lesions can also be applied to SiPM-PET/CT.</p><p><strong>Methods: </strong>We enrolled 21 consecutive patients with head and neck malignancies who underwent whole-body FDG-PET/CT for initial staging or a follow-up evaluation (October 2020 to March 2022). After being injected with FDG, all patients underwent PET acquisition on both Vereos PET-CT and Gemini TF64 PET-CT systems (both Philips Healthcare) in random order. For each patient, the maximum standardized uptake value (SUVmax) was measured in the pituitary gland, esophagogastric junction (EGJ), adrenal glands, lumbar enlargement of the spinal cord, and epididymis. We measured the liver SUVmean and the blood pool SUVmean to calculate the target-to-liver ratio (TLR) and the target-to-blood ratio (TBR), respectively. Between-groups differences in each variable were examined by a paired t-test. We also investigated whether there were cases of target uptake greater than the reported threshold for distinguishing pathological from physiological accumulations.</p><p><strong>Results: </strong>Data were available for 19 patients. Ten patients were in Group 1, i.e., the patients who underwent SiPM-PET first, and the remaining nine patients who underwent cPET first were in Group 2. In the SiPM-PET results, the SUVmax of all targets was significantly higher than that obtained by cPET in all patients, and this tendency was also observed when the patients were divided into Groups 1/2. The TLRs of all targets were significantly higher in SiPM-PET than in cPET in all patients, and SiPM-PET also showed significantly higher TBRs for all targets except the EGJ (p = 0.052).</p><p><strong>Conclusions: </strong>The physiological uptake in the small structures studied herein showed high accumulation on SiPM-PET. Our results also suggest that the thresholds reported for cPET to distinguish pathological accumulations likely lead to false-positive findings in SIPM-PET evaluations.</p>","PeriodicalId":8007,"journal":{"name":"Annals of Nuclear Medicine","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative study of physiological FDG uptake in small structures between silicon photomultiplier-based PET and conventional PET.\",\"authors\":\"Shiro Watanabe, Kenji Hirata, Keiichi Magota, Junki Takenaka, Naoto Wakabayashi, Daiki Shinyama, Koichi Yasuda, Akihiro Homma, Kohsuke Kudo\",\"doi\":\"10.1007/s12149-023-01884-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Silicon photomultiplier-based positron emission tomography/computed tomography (SiPM-PET/CT) has the superior spatial resolution to conventional PET/CT (cPET/CT). This head-to-head comparison study compared the images of physiological <sup>18</sup>F-fluorodeoxyglucose (FDG) accumulation in small-volume structures between SiPM-PET/CT and cPET/CT in patients scanned with both modalities, and we investigated whether the thresholds that are reported to be useful for differentiating physiological accumulations from malignant lesions can also be applied to SiPM-PET/CT.</p><p><strong>Methods: </strong>We enrolled 21 consecutive patients with head and neck malignancies who underwent whole-body FDG-PET/CT for initial staging or a follow-up evaluation (October 2020 to March 2022). After being injected with FDG, all patients underwent PET acquisition on both Vereos PET-CT and Gemini TF64 PET-CT systems (both Philips Healthcare) in random order. For each patient, the maximum standardized uptake value (SUVmax) was measured in the pituitary gland, esophagogastric junction (EGJ), adrenal glands, lumbar enlargement of the spinal cord, and epididymis. We measured the liver SUVmean and the blood pool SUVmean to calculate the target-to-liver ratio (TLR) and the target-to-blood ratio (TBR), respectively. Between-groups differences in each variable were examined by a paired t-test. We also investigated whether there were cases of target uptake greater than the reported threshold for distinguishing pathological from physiological accumulations.</p><p><strong>Results: </strong>Data were available for 19 patients. Ten patients were in Group 1, i.e., the patients who underwent SiPM-PET first, and the remaining nine patients who underwent cPET first were in Group 2. In the SiPM-PET results, the SUVmax of all targets was significantly higher than that obtained by cPET in all patients, and this tendency was also observed when the patients were divided into Groups 1/2. The TLRs of all targets were significantly higher in SiPM-PET than in cPET in all patients, and SiPM-PET also showed significantly higher TBRs for all targets except the EGJ (p = 0.052).</p><p><strong>Conclusions: </strong>The physiological uptake in the small structures studied herein showed high accumulation on SiPM-PET. Our results also suggest that the thresholds reported for cPET to distinguish pathological accumulations likely lead to false-positive findings in SIPM-PET evaluations.</p>\",\"PeriodicalId\":8007,\"journal\":{\"name\":\"Annals of Nuclear Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Nuclear Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s12149-023-01884-3\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Nuclear Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12149-023-01884-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:基于硅光电倍增管的正电子发射断层扫描/计算机断层扫描(SiPM PET/CT)具有优于传统PET/CT(cPET/CT。这项头对头比较研究比较了用两种模式扫描的患者中SiPM PET/CT和cPET/CT之间小体积结构中生理性18F-氟脱氧葡萄糖(FDG)积聚的图像,我们研究了据报道有助于区分生理积聚和恶性病变的阈值是否也适用于SiPM PET/CT。方法:我们招募了21名连续接受全身FDG-PET/CT的头颈部恶性肿瘤患者进行初步分期或随访评估(2020年10月至2022年3月)。在注射FDG后,所有患者在Vereos PET-CT和Gemini TF64 PET-CT系统(均为Philips Healthcare)上按随机顺序进行PET采集。对于每个患者,测量垂体、食管胃交界处(EGJ)、肾上腺、脊髓腰大和附睾的最大标准化摄取值(SUVmax)。我们测量了肝脏SUVmean和血池SUVmeans,以分别计算目标肝脏比(TLR)和目标血液比(TBR)。通过配对t检验检验各组之间每个变量的差异。我们还调查了是否存在靶向摄取大于所报道的区分病理性和生理性积聚的阈值的情况。结果:19例患者的数据可用。10名患者在第1组,即首先接受SiPM PET的患者,其余9名首先接受cPET的患者在第2组。在SiPM PET结果中,在所有患者中,所有靶点的SUVmax都显著高于cPET获得的SUVmax,并且当将患者分为1/2组时也观察到了这种趋势。在所有患者中,SiPM PET中所有靶点的TLR都显著高于cPET,并且SiPM PET也显示出除EGJ之外的所有靶点都显著更高的TBR(p = 0.052)。结论:本文研究的小结构中的生理摄取在SiPM PET上显示出高积累。我们的结果还表明,cPET用于区分病理积聚的阈值可能导致SIPM-PET评估中的假阳性结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparative study of physiological FDG uptake in small structures between silicon photomultiplier-based PET and conventional PET.

Comparative study of physiological FDG uptake in small structures between silicon photomultiplier-based PET and conventional PET.

Objective: Silicon photomultiplier-based positron emission tomography/computed tomography (SiPM-PET/CT) has the superior spatial resolution to conventional PET/CT (cPET/CT). This head-to-head comparison study compared the images of physiological 18F-fluorodeoxyglucose (FDG) accumulation in small-volume structures between SiPM-PET/CT and cPET/CT in patients scanned with both modalities, and we investigated whether the thresholds that are reported to be useful for differentiating physiological accumulations from malignant lesions can also be applied to SiPM-PET/CT.

Methods: We enrolled 21 consecutive patients with head and neck malignancies who underwent whole-body FDG-PET/CT for initial staging or a follow-up evaluation (October 2020 to March 2022). After being injected with FDG, all patients underwent PET acquisition on both Vereos PET-CT and Gemini TF64 PET-CT systems (both Philips Healthcare) in random order. For each patient, the maximum standardized uptake value (SUVmax) was measured in the pituitary gland, esophagogastric junction (EGJ), adrenal glands, lumbar enlargement of the spinal cord, and epididymis. We measured the liver SUVmean and the blood pool SUVmean to calculate the target-to-liver ratio (TLR) and the target-to-blood ratio (TBR), respectively. Between-groups differences in each variable were examined by a paired t-test. We also investigated whether there were cases of target uptake greater than the reported threshold for distinguishing pathological from physiological accumulations.

Results: Data were available for 19 patients. Ten patients were in Group 1, i.e., the patients who underwent SiPM-PET first, and the remaining nine patients who underwent cPET first were in Group 2. In the SiPM-PET results, the SUVmax of all targets was significantly higher than that obtained by cPET in all patients, and this tendency was also observed when the patients were divided into Groups 1/2. The TLRs of all targets were significantly higher in SiPM-PET than in cPET in all patients, and SiPM-PET also showed significantly higher TBRs for all targets except the EGJ (p = 0.052).

Conclusions: The physiological uptake in the small structures studied herein showed high accumulation on SiPM-PET. Our results also suggest that the thresholds reported for cPET to distinguish pathological accumulations likely lead to false-positive findings in SIPM-PET evaluations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of Nuclear Medicine
Annals of Nuclear Medicine 医学-核医学
CiteScore
4.90
自引率
7.70%
发文量
111
审稿时长
4-8 weeks
期刊介绍: Annals of Nuclear Medicine is an official journal of the Japanese Society of Nuclear Medicine. It develops the appropriate application of radioactive substances and stable nuclides in the field of medicine. The journal promotes the exchange of ideas and information and research in nuclear medicine and includes the medical application of radionuclides and related subjects. It presents original articles, short communications, reviews and letters to the editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信