食道测试:目前我们有什么。

N. de Bortoli, I. Martinucci, L. Bertani, S. Russo, R. Franchi, M. Furnari, S. Tolone, G. Bodini, V. Bolognesi, M. Bellini, V. Savarino, S. Marchi, E. Savarino
{"title":"食道测试:目前我们有什么。","authors":"N. de Bortoli, I. Martinucci, L. Bertani, S. Russo, R. Franchi, M. Furnari, S. Tolone, G. Bodini, V. Bolognesi, M. Bellini, V. Savarino, S. Marchi, E. Savarino","doi":"10.4291/wjgp.v7.i1.72","DOIUrl":null,"url":null,"abstract":"Gastroesophageal reflux disease (GERD) is a common disorder of the gastrointestinal tract. In the last few decades, new technologies have evolved and have been applied to the functional study of the esophagus, allowing for the improvement of our knowledge of the pathophysiology of GERD. High-resolution manometry (HRM) permits greater understanding of the function of the esophagogastric junction and the risks associated with hiatal hernia. Moreover, HRM has been found to be more reproducible and sensitive than conventional water-perfused manometry to detect the presence of transient lower esophageal sphincter relaxation. Esophageal 24-h pH-metry with or without combined impedance is usually performed in patients with negative endoscopy and reflux symptoms who have a poor response to anti-reflux medical therapy to assess esophageal acid exposure and symptom-reflux correlations. In particular, esophageal 24-h impedance and pH monitoring can detect acid and non-acid reflux events. EndoFLIP is a recent technique poorly applied in clinical practice, although it provides a large amount of information about the esophagogastric junction. In the coming years, laryngopharyngeal symptoms could be evaluated with up and coming non-invasive or minimally invasive techniques, such as pepsin detection in saliva or pharyngeal pH-metry. Future studies are required of these techniques to evaluate their diagnostic accuracy and usefulness, although the available data are promising.","PeriodicalId":68755,"journal":{"name":"世界胃肠病理生理学杂志(电子版)(英文版)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"28","resultStr":"{\"title\":\"Esophageal testing: What we have so far.\",\"authors\":\"N. de Bortoli, I. Martinucci, L. Bertani, S. Russo, R. Franchi, M. Furnari, S. Tolone, G. Bodini, V. Bolognesi, M. Bellini, V. Savarino, S. Marchi, E. Savarino\",\"doi\":\"10.4291/wjgp.v7.i1.72\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Gastroesophageal reflux disease (GERD) is a common disorder of the gastrointestinal tract. In the last few decades, new technologies have evolved and have been applied to the functional study of the esophagus, allowing for the improvement of our knowledge of the pathophysiology of GERD. High-resolution manometry (HRM) permits greater understanding of the function of the esophagogastric junction and the risks associated with hiatal hernia. Moreover, HRM has been found to be more reproducible and sensitive than conventional water-perfused manometry to detect the presence of transient lower esophageal sphincter relaxation. Esophageal 24-h pH-metry with or without combined impedance is usually performed in patients with negative endoscopy and reflux symptoms who have a poor response to anti-reflux medical therapy to assess esophageal acid exposure and symptom-reflux correlations. In particular, esophageal 24-h impedance and pH monitoring can detect acid and non-acid reflux events. EndoFLIP is a recent technique poorly applied in clinical practice, although it provides a large amount of information about the esophagogastric junction. In the coming years, laryngopharyngeal symptoms could be evaluated with up and coming non-invasive or minimally invasive techniques, such as pepsin detection in saliva or pharyngeal pH-metry. Future studies are required of these techniques to evaluate their diagnostic accuracy and usefulness, although the available data are promising.\",\"PeriodicalId\":68755,\"journal\":{\"name\":\"世界胃肠病理生理学杂志(电子版)(英文版)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"28\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"世界胃肠病理生理学杂志(电子版)(英文版)\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4291/wjgp.v7.i1.72\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"世界胃肠病理生理学杂志(电子版)(英文版)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4291/wjgp.v7.i1.72","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 28

摘要

胃食管反流病(GERD)是一种常见的胃肠道疾病。在过去的几十年里,新技术已经发展并已应用于食道的功能研究,从而提高了我们对胃食管反流病病理生理学的认识。高分辨率测压(HRM)可以更好地了解食管胃交界的功能和裂孔疝的相关风险。此外,与传统的水灌注测压法相比,HRM在检测短暂性下食管括约肌松弛的存在方面具有更高的重复性和灵敏度。食管24小时ph测定(联合阻抗或不联合阻抗)通常用于内窥镜检查阴性且反流症状对抗反流药物治疗反应不佳的患者,以评估食管酸暴露和症状-反流相关性。特别是,食管24小时阻抗和pH监测可以检测酸和非酸反流事件。虽然EndoFLIP提供了大量关于食管胃交界的信息,但它是一项最近在临床实践中应用较少的技术。在未来的几年里,喉部症状可以通过无创或微创技术进行评估,如唾液胃蛋白酶检测或咽部ph测定。尽管现有的数据很有希望,但仍需要对这些技术进行进一步的研究,以评估其诊断的准确性和有用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Esophageal testing: What we have so far.
Gastroesophageal reflux disease (GERD) is a common disorder of the gastrointestinal tract. In the last few decades, new technologies have evolved and have been applied to the functional study of the esophagus, allowing for the improvement of our knowledge of the pathophysiology of GERD. High-resolution manometry (HRM) permits greater understanding of the function of the esophagogastric junction and the risks associated with hiatal hernia. Moreover, HRM has been found to be more reproducible and sensitive than conventional water-perfused manometry to detect the presence of transient lower esophageal sphincter relaxation. Esophageal 24-h pH-metry with or without combined impedance is usually performed in patients with negative endoscopy and reflux symptoms who have a poor response to anti-reflux medical therapy to assess esophageal acid exposure and symptom-reflux correlations. In particular, esophageal 24-h impedance and pH monitoring can detect acid and non-acid reflux events. EndoFLIP is a recent technique poorly applied in clinical practice, although it provides a large amount of information about the esophagogastric junction. In the coming years, laryngopharyngeal symptoms could be evaluated with up and coming non-invasive or minimally invasive techniques, such as pepsin detection in saliva or pharyngeal pH-metry. Future studies are required of these techniques to evaluate their diagnostic accuracy and usefulness, although the available data are promising.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
336
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信