{"title":"两种椭球模型估算冠心病患者左室收缩末期应力的比较。","authors":"Zeinab Alsadat Ahmadi, Manijhe Mokhtari Dizaji, Anita Sadeghpour, Hamideh Khesali, Ata Firouzi","doi":"10.4103/jrms.jrms_4_21","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The shape of the left ventricle (LV) is an important index to explore cardiac pathophysiology. A comparison was provided to estimate circumferential, longitudinal, and radial wall stress in LV based on the thick-walled ellipsoidal models of Mirsky and Ghista-Sandler for discriminating significant coronary artery disease (CAD) patients from no CAD patients.</p><p><strong>Materials and methods: </strong>According to the angiography findings, 82 patients with CAD were divided into two groups: 25 patients without significant CAD and 57 patients with significant CAD of single vessel and multivessel. An ellipsoidal LV geometry was used to calculate end-systolic passive stress as the mechanical behavior of LV. Echocardiographic views-based measurements of LV diameters used to estimate the end-systolic wall stress.</p><p><strong>Results: </strong>Circumferential wall stress between the control group and significant CAD groups was significantly elevated for the Ghista model (<i>P</i> = 0.008); also, radial and longitudinal stress of the multi-vessel CAD group was significantly higher than the control group (<i>P</i> = 0.01 and <i>P</i> = 0.005, respectively). All stress parameters of the multi-vessel CAD group were statistically significant compared to the control group for the Mirsky model. Receiver operating characteristics curve analysis was shown the circumferential stress of multi-vessel CAD with an area under the curve (AUC) of 0.736 for the Ghista model and an AUC of 0.742 for the Mirsky model.</p><p><strong>Conclusion: </strong>These results indicated that Ghista and Mirsky model estimates of circumferential passive stress were the potential biomechanical markers to predict patients with multi-vessel CAD. It could be a noninvasive and helpful tool to quantify the contractility of LV.</p>","PeriodicalId":50062,"journal":{"name":"Journal of Research in Medical Sciences","volume":"1 1","pages":"62"},"PeriodicalIF":1.5000,"publicationDate":"2023-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10668221/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of two ellipsoidal models for the estimation of left ventricular end-systolic stress in patients with significant coronary artery disease.\",\"authors\":\"Zeinab Alsadat Ahmadi, Manijhe Mokhtari Dizaji, Anita Sadeghpour, Hamideh Khesali, Ata Firouzi\",\"doi\":\"10.4103/jrms.jrms_4_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The shape of the left ventricle (LV) is an important index to explore cardiac pathophysiology. A comparison was provided to estimate circumferential, longitudinal, and radial wall stress in LV based on the thick-walled ellipsoidal models of Mirsky and Ghista-Sandler for discriminating significant coronary artery disease (CAD) patients from no CAD patients.</p><p><strong>Materials and methods: </strong>According to the angiography findings, 82 patients with CAD were divided into two groups: 25 patients without significant CAD and 57 patients with significant CAD of single vessel and multivessel. An ellipsoidal LV geometry was used to calculate end-systolic passive stress as the mechanical behavior of LV. Echocardiographic views-based measurements of LV diameters used to estimate the end-systolic wall stress.</p><p><strong>Results: </strong>Circumferential wall stress between the control group and significant CAD groups was significantly elevated for the Ghista model (<i>P</i> = 0.008); also, radial and longitudinal stress of the multi-vessel CAD group was significantly higher than the control group (<i>P</i> = 0.01 and <i>P</i> = 0.005, respectively). All stress parameters of the multi-vessel CAD group were statistically significant compared to the control group for the Mirsky model. Receiver operating characteristics curve analysis was shown the circumferential stress of multi-vessel CAD with an area under the curve (AUC) of 0.736 for the Ghista model and an AUC of 0.742 for the Mirsky model.</p><p><strong>Conclusion: </strong>These results indicated that Ghista and Mirsky model estimates of circumferential passive stress were the potential biomechanical markers to predict patients with multi-vessel CAD. It could be a noninvasive and helpful tool to quantify the contractility of LV.</p>\",\"PeriodicalId\":50062,\"journal\":{\"name\":\"Journal of Research in Medical Sciences\",\"volume\":\"1 1\",\"pages\":\"62\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10668221/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Research in Medical Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/jrms.jrms_4_21\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research in Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/jrms.jrms_4_21","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Comparison of two ellipsoidal models for the estimation of left ventricular end-systolic stress in patients with significant coronary artery disease.
Background: The shape of the left ventricle (LV) is an important index to explore cardiac pathophysiology. A comparison was provided to estimate circumferential, longitudinal, and radial wall stress in LV based on the thick-walled ellipsoidal models of Mirsky and Ghista-Sandler for discriminating significant coronary artery disease (CAD) patients from no CAD patients.
Materials and methods: According to the angiography findings, 82 patients with CAD were divided into two groups: 25 patients without significant CAD and 57 patients with significant CAD of single vessel and multivessel. An ellipsoidal LV geometry was used to calculate end-systolic passive stress as the mechanical behavior of LV. Echocardiographic views-based measurements of LV diameters used to estimate the end-systolic wall stress.
Results: Circumferential wall stress between the control group and significant CAD groups was significantly elevated for the Ghista model (P = 0.008); also, radial and longitudinal stress of the multi-vessel CAD group was significantly higher than the control group (P = 0.01 and P = 0.005, respectively). All stress parameters of the multi-vessel CAD group were statistically significant compared to the control group for the Mirsky model. Receiver operating characteristics curve analysis was shown the circumferential stress of multi-vessel CAD with an area under the curve (AUC) of 0.736 for the Ghista model and an AUC of 0.742 for the Mirsky model.
Conclusion: These results indicated that Ghista and Mirsky model estimates of circumferential passive stress were the potential biomechanical markers to predict patients with multi-vessel CAD. It could be a noninvasive and helpful tool to quantify the contractility of LV.
期刊介绍:
Journal of Research in Medical Sciences, a publication of Isfahan University of Medical Sciences, is a peer-reviewed online continuous journal with print on demand compilation of issues published. The journal’s full text is available online at http://www.jmsjournal.net. The journal allows free access (Open Access) to its contents and permits authors to self-archive final accepted version of the articles on any OAI-compliant institutional / subject-based repository.