{"title":"一种新的无电解电容永磁同步电机正交电压约束弱磁控制方法","authors":"Junya Huo;Dawei Ding;Zekun Ren;Gaolin Wang;Nannan Zhao;Lianghong Zhu;Dianguo Xu","doi":"10.30941/CESTEMS.2022.00038","DOIUrl":null,"url":null,"abstract":"In electrolytic capacitorless permanent magnet synchronous motor (PMSM) drives, the DC-link voltage will fluctuate in a wide range due to the use of slim film capacitor. When the flux-weakening current is lower than \n<tex>$-\\psi_{\\mathrm{f}}/L_{\\mathrm{d}}$</tex>\n during the high speed operation, the flux-weakening control loop will transform to a positive feedback mode, which means the reduction of flux-weakening current will lead to the acceleration of the voltage saturation, thus the whole system will be unstable. In order to solve this issue, this paper proposes a novel flux-weakening method for electrolytic capacitorless motor drives to maintain a negative feedback characteristic of the control loop during high speed operation. Based on the analysis of the instability mechanism in flux-weakening region, a quadrature voltage constrain mechanism is constructed to stabilize the system. Meanwhile, the parameters of the controller are theoretically designed for easier industrial application. The proposed algorithm is implemented on a 1.5kW electrolytic capacitorless PMSM drive to verify the effectiveness of the flux-weakening performance.","PeriodicalId":100229,"journal":{"name":"CES Transactions on Electrical Machines and Systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/7873789/9910348/09910359.pdf","citationCount":"2","resultStr":"{\"title\":\"A Novel Flux-weakening Control Method with Quadrature Voltage Constrain for Electrolytic Capacitorless PMSM Drives\",\"authors\":\"Junya Huo;Dawei Ding;Zekun Ren;Gaolin Wang;Nannan Zhao;Lianghong Zhu;Dianguo Xu\",\"doi\":\"10.30941/CESTEMS.2022.00038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In electrolytic capacitorless permanent magnet synchronous motor (PMSM) drives, the DC-link voltage will fluctuate in a wide range due to the use of slim film capacitor. When the flux-weakening current is lower than \\n<tex>$-\\\\psi_{\\\\mathrm{f}}/L_{\\\\mathrm{d}}$</tex>\\n during the high speed operation, the flux-weakening control loop will transform to a positive feedback mode, which means the reduction of flux-weakening current will lead to the acceleration of the voltage saturation, thus the whole system will be unstable. In order to solve this issue, this paper proposes a novel flux-weakening method for electrolytic capacitorless motor drives to maintain a negative feedback characteristic of the control loop during high speed operation. Based on the analysis of the instability mechanism in flux-weakening region, a quadrature voltage constrain mechanism is constructed to stabilize the system. Meanwhile, the parameters of the controller are theoretically designed for easier industrial application. The proposed algorithm is implemented on a 1.5kW electrolytic capacitorless PMSM drive to verify the effectiveness of the flux-weakening performance.\",\"PeriodicalId\":100229,\"journal\":{\"name\":\"CES Transactions on Electrical Machines and Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/iel7/7873789/9910348/09910359.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CES Transactions on Electrical Machines and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9910359/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CES Transactions on Electrical Machines and Systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/9910359/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Novel Flux-weakening Control Method with Quadrature Voltage Constrain for Electrolytic Capacitorless PMSM Drives
In electrolytic capacitorless permanent magnet synchronous motor (PMSM) drives, the DC-link voltage will fluctuate in a wide range due to the use of slim film capacitor. When the flux-weakening current is lower than
$-\psi_{\mathrm{f}}/L_{\mathrm{d}}$
during the high speed operation, the flux-weakening control loop will transform to a positive feedback mode, which means the reduction of flux-weakening current will lead to the acceleration of the voltage saturation, thus the whole system will be unstable. In order to solve this issue, this paper proposes a novel flux-weakening method for electrolytic capacitorless motor drives to maintain a negative feedback characteristic of the control loop during high speed operation. Based on the analysis of the instability mechanism in flux-weakening region, a quadrature voltage constrain mechanism is constructed to stabilize the system. Meanwhile, the parameters of the controller are theoretically designed for easier industrial application. The proposed algorithm is implemented on a 1.5kW electrolytic capacitorless PMSM drive to verify the effectiveness of the flux-weakening performance.