交叉反应物质阳性型因子vii异常

Shinya, Kimural, Kazuo, Ochil, Shogo, Yamamotol, Naoyuki, Maruo, Motoharu, Kondo, Sadaaki, Mikami, Osamu, Takamiya
{"title":"交叉反应物质阳性型因子vii异常","authors":"Shinya, Kimural, Kazuo, Ochil, Shogo, Yamamotol, Naoyuki, Maruo, Motoharu, Kondo, Sadaaki, Mikami, Osamu, Takamiya","doi":"10.3925/jjtc1958.38.463","DOIUrl":null,"url":null,"abstract":"A case of cross reacting material positive (CRM+) type factor VII deficiency is presented. The patient was 58 years old female and had no serious bleeding episodes. Her parents were consanguineous. Prothrombin time was prolonged but partial thromboplastin time was normal. Factor VII activity measured by one stage assay with any type of thromboplastins was decreased to the level of 1%-7%. However, Factor VII antigen (cross reacting material) measured by a radioimmunoassay was normal level. The examination of other coagulation factors showed normal levels. Several other members of the family showed heterozygotes with relation to the same abnormality.","PeriodicalId":86521,"journal":{"name":"Nihon Yuketsu Gakkai zasshi = Journal of the Japan Society of Blood Transfusion","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CROSS REACTING METERIAL POSITIVE TYPE FACTOR VII ABNORMALITY\",\"authors\":\"Shinya, Kimural, Kazuo, Ochil, Shogo, Yamamotol, Naoyuki, Maruo, Motoharu, Kondo, Sadaaki, Mikami, Osamu, Takamiya\",\"doi\":\"10.3925/jjtc1958.38.463\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A case of cross reacting material positive (CRM+) type factor VII deficiency is presented. The patient was 58 years old female and had no serious bleeding episodes. Her parents were consanguineous. Prothrombin time was prolonged but partial thromboplastin time was normal. Factor VII activity measured by one stage assay with any type of thromboplastins was decreased to the level of 1%-7%. However, Factor VII antigen (cross reacting material) measured by a radioimmunoassay was normal level. The examination of other coagulation factors showed normal levels. Several other members of the family showed heterozygotes with relation to the same abnormality.\",\"PeriodicalId\":86521,\"journal\":{\"name\":\"Nihon Yuketsu Gakkai zasshi = Journal of the Japan Society of Blood Transfusion\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Yuketsu Gakkai zasshi = Journal of the Japan Society of Blood Transfusion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3925/jjtc1958.38.463\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Yuketsu Gakkai zasshi = Journal of the Japan Society of Blood Transfusion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3925/jjtc1958.38.463","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一个交叉反应物质阳性(CRM+)型VII因子缺乏的病例。患者女,58岁,无严重出血。她的父母是近亲。凝血酶原时间延长,部分凝血活酶时间正常。因子VII活性测定与任何类型的凝血酶一期试验下降到1%-7%的水平。放射免疫法检测因子7抗原(交叉反应物质)正常。其他凝血因子检查均正常。该家族的其他几个成员表现出与相同异常有关的杂合子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CROSS REACTING METERIAL POSITIVE TYPE FACTOR VII ABNORMALITY
A case of cross reacting material positive (CRM+) type factor VII deficiency is presented. The patient was 58 years old female and had no serious bleeding episodes. Her parents were consanguineous. Prothrombin time was prolonged but partial thromboplastin time was normal. Factor VII activity measured by one stage assay with any type of thromboplastins was decreased to the level of 1%-7%. However, Factor VII antigen (cross reacting material) measured by a radioimmunoassay was normal level. The examination of other coagulation factors showed normal levels. Several other members of the family showed heterozygotes with relation to the same abnormality.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信