{"title":"聚氯乙烯基膜新型聚合物电极测定盐酸阿米洛利药物的研究与构建","authors":"S. A. Abrahem, S. Ibrahim, A. Kader","doi":"10.33422/2nd.icarbme.2019.12.945","DOIUrl":null,"url":null,"abstract":"Based on Amiloride hydrochloride-methyl orange, two electrodes of Amiloride hydrochloride were constructed in PVC matrix as ion pair complex. They were plasticized using Nitrobenzene (NB), and Di-butyl phosphate (DBP). Amiloride hydrochloride (AMH) electrodes (e1and e2) presented slopes (54.210 and 52.810 mV/decade) and linear ranges (10-5-10-2, and 2*10-5-10-2 M), respectively. (e1), which is the best electrode, was based on DBP plasticizer. It gave a detection limit of 4x10-6M, slope of 54.210 mV/decade, correlation coefficient 0.9998, lifetime 36 days. The proposed electrode displayed reproducibility and good stability and was used for determining Amiloride hydrochloride in pharmaceutical samples. The interference measurements using (Na+, Cu+2, K+, Fe+3, and Mn+2) were studied for selectivity coefficient determination using the separated method, as well as the mixed method","PeriodicalId":15222,"journal":{"name":"Journal of Cardiovascular Disease Research","volume":"11 1","pages":"150-155"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study and Construction of New Polymeric Electrodes in PVC Matrix Membrane for Amiloride Hydrochloride Drug Determination\",\"authors\":\"S. A. Abrahem, S. Ibrahim, A. Kader\",\"doi\":\"10.33422/2nd.icarbme.2019.12.945\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on Amiloride hydrochloride-methyl orange, two electrodes of Amiloride hydrochloride were constructed in PVC matrix as ion pair complex. They were plasticized using Nitrobenzene (NB), and Di-butyl phosphate (DBP). Amiloride hydrochloride (AMH) electrodes (e1and e2) presented slopes (54.210 and 52.810 mV/decade) and linear ranges (10-5-10-2, and 2*10-5-10-2 M), respectively. (e1), which is the best electrode, was based on DBP plasticizer. It gave a detection limit of 4x10-6M, slope of 54.210 mV/decade, correlation coefficient 0.9998, lifetime 36 days. The proposed electrode displayed reproducibility and good stability and was used for determining Amiloride hydrochloride in pharmaceutical samples. The interference measurements using (Na+, Cu+2, K+, Fe+3, and Mn+2) were studied for selectivity coefficient determination using the separated method, as well as the mixed method\",\"PeriodicalId\":15222,\"journal\":{\"name\":\"Journal of Cardiovascular Disease Research\",\"volume\":\"11 1\",\"pages\":\"150-155\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Disease Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33422/2nd.icarbme.2019.12.945\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Disease Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33422/2nd.icarbme.2019.12.945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
Study and Construction of New Polymeric Electrodes in PVC Matrix Membrane for Amiloride Hydrochloride Drug Determination
Based on Amiloride hydrochloride-methyl orange, two electrodes of Amiloride hydrochloride were constructed in PVC matrix as ion pair complex. They were plasticized using Nitrobenzene (NB), and Di-butyl phosphate (DBP). Amiloride hydrochloride (AMH) electrodes (e1and e2) presented slopes (54.210 and 52.810 mV/decade) and linear ranges (10-5-10-2, and 2*10-5-10-2 M), respectively. (e1), which is the best electrode, was based on DBP plasticizer. It gave a detection limit of 4x10-6M, slope of 54.210 mV/decade, correlation coefficient 0.9998, lifetime 36 days. The proposed electrode displayed reproducibility and good stability and was used for determining Amiloride hydrochloride in pharmaceutical samples. The interference measurements using (Na+, Cu+2, K+, Fe+3, and Mn+2) were studied for selectivity coefficient determination using the separated method, as well as the mixed method