灌注SPECT在老年痴呆的诊断中还有一席之地吗?

Klaus P. Ebmeier
{"title":"灌注SPECT在老年痴呆的诊断中还有一席之地吗?","authors":"Klaus P. Ebmeier","doi":"10.2174/1876388X01002020040","DOIUrl":null,"url":null,"abstract":"Although research interest within functional imaging has moved towards applications of MRI, such as BOLD and perfusion imaging, there is a wealth of clinical experience in emission tomographic imaging techniques that make the use of these modalities relevant for the decades to come. This review touches upon the technical and practical issues that distinguish SPECT from PET, describes perfusion and metabolic changes observed in the dementias, compares the clinical utility of the two techniques, and reports data on clinical sensitivity and specificity, as well as diagnostic head-to head comparisons in dementia, and specifically Alzheimer’s disease. While few centres have a genuine choice between PET and SPECT, either appears to be good enough to help with the differential diagnosis of dementia in difficult cases.","PeriodicalId":88754,"journal":{"name":"The open nuclear medicine journal","volume":"2 1","pages":"40-45"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Is there Still a Place for Perfusion SPECT in the Diagnosis of Dementia?~!2009-10-15~!2010-01-22~!2010-05-06~!\",\"authors\":\"Klaus P. Ebmeier\",\"doi\":\"10.2174/1876388X01002020040\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Although research interest within functional imaging has moved towards applications of MRI, such as BOLD and perfusion imaging, there is a wealth of clinical experience in emission tomographic imaging techniques that make the use of these modalities relevant for the decades to come. This review touches upon the technical and practical issues that distinguish SPECT from PET, describes perfusion and metabolic changes observed in the dementias, compares the clinical utility of the two techniques, and reports data on clinical sensitivity and specificity, as well as diagnostic head-to head comparisons in dementia, and specifically Alzheimer’s disease. While few centres have a genuine choice between PET and SPECT, either appears to be good enough to help with the differential diagnosis of dementia in difficult cases.\",\"PeriodicalId\":88754,\"journal\":{\"name\":\"The open nuclear medicine journal\",\"volume\":\"2 1\",\"pages\":\"40-45\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The open nuclear medicine journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1876388X01002020040\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The open nuclear medicine journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1876388X01002020040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

尽管功能成像的研究兴趣已经转向MRI的应用,如BOLD和灌注成像,但在发射层析成像技术方面有丰富的临床经验,使这些技术的使用在未来几十年具有相关性。这篇综述涉及区分SPECT和PET的技术和实际问题,描述了在痴呆症中观察到的灌注和代谢变化,比较了两种技术的临床应用,并报告了临床敏感性和特异性的数据,以及痴呆,特别是阿尔茨海默病的诊断头对头比较。虽然很少有中心能够在PET和SPECT之间做出真正的选择,但两者似乎都足以帮助对困难病例的痴呆进行鉴别诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Is there Still a Place for Perfusion SPECT in the Diagnosis of Dementia?~!2009-10-15~!2010-01-22~!2010-05-06~!
Although research interest within functional imaging has moved towards applications of MRI, such as BOLD and perfusion imaging, there is a wealth of clinical experience in emission tomographic imaging techniques that make the use of these modalities relevant for the decades to come. This review touches upon the technical and practical issues that distinguish SPECT from PET, describes perfusion and metabolic changes observed in the dementias, compares the clinical utility of the two techniques, and reports data on clinical sensitivity and specificity, as well as diagnostic head-to head comparisons in dementia, and specifically Alzheimer’s disease. While few centres have a genuine choice between PET and SPECT, either appears to be good enough to help with the differential diagnosis of dementia in difficult cases.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信