CAD/CAM和3D打印在猫股骨颈骨折治疗中的准确性

IF 0.4 4区 农林科学 Q4 VETERINARY SCIENCES
{"title":"CAD/CAM和3D打印在猫股骨颈骨折治疗中的准确性","authors":"","doi":"10.21521/mw.6772","DOIUrl":null,"url":null,"abstract":"The aim of this study was to investigate whether a CT scan provides accurate bone surface information for feline bone model development. The second part of study consisted of 3D printing of feline femoral bone models with and without femoral neck fractures (31-B1 and 31-B2 in AO VET classification), as well as the development and 3D printing of drill guides for treatment of femoral neck fractures. The study was carried out on eight models of femoral bones and four drill guides. Initially, trial models of the right and left femurs without neck fractures and trial drill guides were used. Radiographs showed that the use of the prototype guides made it possible to drill holes in the axes of the necks of the femurs. Then, after assessing the correct operation of the guides and improving their adhesion to the bone surface by smoothing the inner surfaces of the guide bases, final bone models without femoral neck fracture, models with fractures 31-B1 and 31-B2, and final drill guides were printed. All models featured a 2.7 × 30 mm positional cortical screw. Radiographs of the models, made after inserting screws, showed that the implants were placed as intended. Also in the longitudinal sections of the heads and necks of the femoral bones of the models without fractures, the implants were positioned in the intended places.","PeriodicalId":49017,"journal":{"name":"Medycyna Weterynaryjna-Veterinary Medicine-Science and Practice","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of CAD/CAM and 3D printing in the treatment of feline femoral neck fracture\",\"authors\":\"\",\"doi\":\"10.21521/mw.6772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study was to investigate whether a CT scan provides accurate bone surface information for feline bone model development. The second part of study consisted of 3D printing of feline femoral bone models with and without femoral neck fractures (31-B1 and 31-B2 in AO VET classification), as well as the development and 3D printing of drill guides for treatment of femoral neck fractures. The study was carried out on eight models of femoral bones and four drill guides. Initially, trial models of the right and left femurs without neck fractures and trial drill guides were used. Radiographs showed that the use of the prototype guides made it possible to drill holes in the axes of the necks of the femurs. Then, after assessing the correct operation of the guides and improving their adhesion to the bone surface by smoothing the inner surfaces of the guide bases, final bone models without femoral neck fracture, models with fractures 31-B1 and 31-B2, and final drill guides were printed. All models featured a 2.7 × 30 mm positional cortical screw. Radiographs of the models, made after inserting screws, showed that the implants were placed as intended. Also in the longitudinal sections of the heads and necks of the femoral bones of the models without fractures, the implants were positioned in the intended places.\",\"PeriodicalId\":49017,\"journal\":{\"name\":\"Medycyna Weterynaryjna-Veterinary Medicine-Science and Practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medycyna Weterynaryjna-Veterinary Medicine-Science and Practice\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.21521/mw.6772\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medycyna Weterynaryjna-Veterinary Medicine-Science and Practice","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.21521/mw.6772","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是研究CT扫描是否为猫骨模型的发育提供准确的骨表面信息。研究的第二部分是3D打印有和没有股骨颈骨折的猫股骨模型(AO VET分类为31-B1和31-B2),以及用于治疗股骨颈骨折的钻头的开发和3D打印。在8个股骨模型和4个钻孔导轨上进行了研究。最初,使用无颈骨折的左右股骨试验模型和试验钻头导向。x光片显示,使用原型导轨可以在股骨颈的轴线上钻孔。然后,在评估导轨的正确操作并通过平滑导轨底座内表面来提高其与骨表面的粘附性后,打印无股骨颈骨折的最终骨模型、31-B1和31-B2骨折模型以及最终的钻头导轨。所有模型均采用2.7 × 30 mm定位皮质螺钉。置入螺钉后拍摄的模型x线片显示植入物按预期放置。同样在没有骨折的模型的股骨头的头部和颈部的纵剖面上,植入物被放置在预定的位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of CAD/CAM and 3D printing in the treatment of feline femoral neck fracture
The aim of this study was to investigate whether a CT scan provides accurate bone surface information for feline bone model development. The second part of study consisted of 3D printing of feline femoral bone models with and without femoral neck fractures (31-B1 and 31-B2 in AO VET classification), as well as the development and 3D printing of drill guides for treatment of femoral neck fractures. The study was carried out on eight models of femoral bones and four drill guides. Initially, trial models of the right and left femurs without neck fractures and trial drill guides were used. Radiographs showed that the use of the prototype guides made it possible to drill holes in the axes of the necks of the femurs. Then, after assessing the correct operation of the guides and improving their adhesion to the bone surface by smoothing the inner surfaces of the guide bases, final bone models without femoral neck fracture, models with fractures 31-B1 and 31-B2, and final drill guides were printed. All models featured a 2.7 × 30 mm positional cortical screw. Radiographs of the models, made after inserting screws, showed that the implants were placed as intended. Also in the longitudinal sections of the heads and necks of the femoral bones of the models without fractures, the implants were positioned in the intended places.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
73
审稿时长
4-8 weeks
期刊介绍: "Medycyna Weterynaryjna" publishes various types of articles which are grouped in the following editorial categories: reviews, original studies, scientific and professional problems, the history of veterinary medicine, posthumous memoirs, as well as chronicles that briefly relate scientific advances and developments in the veterinary profession and medicine. The most important are the first two categories, which are published with short summaries in English. Moreover, from 2001 the editors of "Medycyna Weterynaryjna", bearing in mind market demands, has also started publishing entire works in English. Since 2008 the periodical has appeared in an electronic version. The following are available in this version: summaries of studies published from 1999 to 2005, full versions of all the studies published in the years 2006-2011 (in pdf files), and full versions of the English studies published in the current year (pdf). Only summaries of the remaining studies from the current year are available. In accordance with the principles accepted by the editors, the full versions of these texts will not be made available until next year. All articles are evaluated twice by leading Polish scientists and professionals before they are considered for publication. For years now "Medycyna Weterynaryjna" has maintained a high standard thanks to this system. The review articles are actually succinct monographs dealing with specific scientific and professional problems that are based on the most recent findings. Original works have a particular value, since they present research carried out in Polish and international scientific centers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信