用于自动化化学分析仪的高通量通用维生素D测定

Saida Fb, C. Yuan
{"title":"用于自动化化学分析仪的高通量通用维生素D测定","authors":"Saida Fb, C. Yuan","doi":"10.16966/2572-9578.132","DOIUrl":null,"url":null,"abstract":"A growing body of scientific literature has been showing the importance of measuring the serum levels of 25-OH Vitamin D (considered to be a reliable indicator of the overall Vitamin D status of a patient). Since the development of the first immuno-assays for 25-OH Vitamin D (over four decades ago), significant improvements have been made in the way 25-OH Vitamin D serum levels are measured. These improvements are, however, still lagging when compared to the exponential demand for Vitamin D testing in clinical settings. Indeed, current 25-OH Vitamin D assays are still slow, have low throughput and are still performed by a limited number of clinical laboratories. In this article, we report on a rapid technique to measure serum 25-OH Vitamin D that uses only two reagents and that can be adapted to virtually any automated spectrophotometric chemistry analyzer. The new technique uses polystyrene (latex) nanoparticles that have been sensitized with Vitamin D-specific antibodies. Extensive performance testing of this new 25-OH Vitamin D assay (namely the Diazyme EZ Vitamin D Assay) has been performed on one of the most common clinical chemistry analyzer (the Beckman AU680). Results show that the assay is sensitive, precise, linear, accurate and fast (throughput over 600 tests per hour). The assay has received approval for clinical use by the US Food and Drug Administration (FDA) and is certified (for accuracy and precision) by the Center for Disease Control and Prevention (CDC).","PeriodicalId":92069,"journal":{"name":"Journal of clinical and laboratory medicine","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A High Throughput Universal Vitamin D Assay for Automated Chemistry Analyzers\",\"authors\":\"Saida Fb, C. Yuan\",\"doi\":\"10.16966/2572-9578.132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A growing body of scientific literature has been showing the importance of measuring the serum levels of 25-OH Vitamin D (considered to be a reliable indicator of the overall Vitamin D status of a patient). Since the development of the first immuno-assays for 25-OH Vitamin D (over four decades ago), significant improvements have been made in the way 25-OH Vitamin D serum levels are measured. These improvements are, however, still lagging when compared to the exponential demand for Vitamin D testing in clinical settings. Indeed, current 25-OH Vitamin D assays are still slow, have low throughput and are still performed by a limited number of clinical laboratories. In this article, we report on a rapid technique to measure serum 25-OH Vitamin D that uses only two reagents and that can be adapted to virtually any automated spectrophotometric chemistry analyzer. The new technique uses polystyrene (latex) nanoparticles that have been sensitized with Vitamin D-specific antibodies. Extensive performance testing of this new 25-OH Vitamin D assay (namely the Diazyme EZ Vitamin D Assay) has been performed on one of the most common clinical chemistry analyzer (the Beckman AU680). Results show that the assay is sensitive, precise, linear, accurate and fast (throughput over 600 tests per hour). The assay has received approval for clinical use by the US Food and Drug Administration (FDA) and is certified (for accuracy and precision) by the Center for Disease Control and Prevention (CDC).\",\"PeriodicalId\":92069,\"journal\":{\"name\":\"Journal of clinical and laboratory medicine\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical and laboratory medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.16966/2572-9578.132\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical and laboratory medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.16966/2572-9578.132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

越来越多的科学文献显示了测量血清25-OH维生素D水平的重要性(被认为是患者整体维生素D水平的可靠指标)。自从25-OH维生素D的第一次免疫测定(四十多年前)发展以来,25-OH维生素D血清水平的测量方法已经取得了重大进展。然而,与临床环境中维生素D检测的指数需求相比,这些改进仍然滞后。事实上,目前的25-OH维生素D测定仍然缓慢,通量低,并且仍然由有限数量的临床实验室进行。在本文中,我们报告了一种快速测量血清25-OH维生素D的技术,该技术仅使用两种试剂,可适用于几乎任何自动化分光光度化学分析仪。这项新技术使用了聚苯乙烯(乳胶)纳米颗粒,这些纳米颗粒已经被维生素d特异性抗体致敏。这种新的25-OH维生素D测定(即Diazyme EZ维生素D测定)的广泛性能测试已在最常见的临床化学分析仪之一(Beckman AU680)上进行。结果表明,该检测方法灵敏、精确、线性、准确、快速(吞吐量超过600次/小时)。该检测方法已获得美国食品和药物管理局(FDA)的临床使用批准,并获得美国疾病控制与预防中心(CDC)的准确性和精密度认证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A High Throughput Universal Vitamin D Assay for Automated Chemistry Analyzers
A growing body of scientific literature has been showing the importance of measuring the serum levels of 25-OH Vitamin D (considered to be a reliable indicator of the overall Vitamin D status of a patient). Since the development of the first immuno-assays for 25-OH Vitamin D (over four decades ago), significant improvements have been made in the way 25-OH Vitamin D serum levels are measured. These improvements are, however, still lagging when compared to the exponential demand for Vitamin D testing in clinical settings. Indeed, current 25-OH Vitamin D assays are still slow, have low throughput and are still performed by a limited number of clinical laboratories. In this article, we report on a rapid technique to measure serum 25-OH Vitamin D that uses only two reagents and that can be adapted to virtually any automated spectrophotometric chemistry analyzer. The new technique uses polystyrene (latex) nanoparticles that have been sensitized with Vitamin D-specific antibodies. Extensive performance testing of this new 25-OH Vitamin D assay (namely the Diazyme EZ Vitamin D Assay) has been performed on one of the most common clinical chemistry analyzer (the Beckman AU680). Results show that the assay is sensitive, precise, linear, accurate and fast (throughput over 600 tests per hour). The assay has received approval for clinical use by the US Food and Drug Administration (FDA) and is certified (for accuracy and precision) by the Center for Disease Control and Prevention (CDC).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信