自动代谢系统在FPGA中的放置

IF 0.5 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
Darius Kulakovskis, D. Navakauskas
{"title":"自动代谢系统在FPGA中的放置","authors":"Darius Kulakovskis, D. Navakauskas","doi":"10.1515/ecce-2016-0001","DOIUrl":null,"url":null,"abstract":"Abstract An original Very High Speed Integrated Circuit Hardware Description Language (VHDL) code generation tool that can be used to automate Metabolic P (MP) system implementation in hardware such as Field Programmable Gate Arrays (FPGA) is described. Unlike P systems, MP systems use a single membrane in their computations. Nevertheless, there are many biological processes that have been successfully modeled by MP systems in software. This is the first attempt to analyze MP system hardware implementations. Two different MP systems are investigated with the purpose of verifying the developed software: the model of glucose–insulin interactions in the Intravenous Glucose Tolerance Test (IVGTT), and the Non-Photochemical Quenching process. The implemented systems’ calculation accuracy and hardware resource usage are examined. It is found that code generation tool works adequately; however, a final decision has to be done by the developer because sometimes several implementation architecture alternatives have to be considered. As an archetypical example serves the IVGTT MP systems’ 21–23 bits FPGA implementation manifesting this in the Digital Signal Processor (DSP), slice, and 4-input LUT usage.","PeriodicalId":42365,"journal":{"name":"Electrical Control and Communication Engineering","volume":"10 1","pages":"12 - 5"},"PeriodicalIF":0.5000,"publicationDate":"2016-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Automated Metabolic P System Placement in FPGA\",\"authors\":\"Darius Kulakovskis, D. Navakauskas\",\"doi\":\"10.1515/ecce-2016-0001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract An original Very High Speed Integrated Circuit Hardware Description Language (VHDL) code generation tool that can be used to automate Metabolic P (MP) system implementation in hardware such as Field Programmable Gate Arrays (FPGA) is described. Unlike P systems, MP systems use a single membrane in their computations. Nevertheless, there are many biological processes that have been successfully modeled by MP systems in software. This is the first attempt to analyze MP system hardware implementations. Two different MP systems are investigated with the purpose of verifying the developed software: the model of glucose–insulin interactions in the Intravenous Glucose Tolerance Test (IVGTT), and the Non-Photochemical Quenching process. The implemented systems’ calculation accuracy and hardware resource usage are examined. It is found that code generation tool works adequately; however, a final decision has to be done by the developer because sometimes several implementation architecture alternatives have to be considered. As an archetypical example serves the IVGTT MP systems’ 21–23 bits FPGA implementation manifesting this in the Digital Signal Processor (DSP), slice, and 4-input LUT usage.\",\"PeriodicalId\":42365,\"journal\":{\"name\":\"Electrical Control and Communication Engineering\",\"volume\":\"10 1\",\"pages\":\"12 - 5\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2016-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrical Control and Communication Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/ecce-2016-0001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Control and Communication Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/ecce-2016-0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 3

摘要

摘要介绍了一种独创的超高速集成电路硬件描述语言(VHDL)代码生成工具,该工具可用于在现场可编程门阵列(FPGA)等硬件上实现代谢性P (MP)系统的自动化。与P系统不同,MP系统在计算中使用单个膜。然而,有许多生物过程已经成功地由MP系统在软件中建模。这是第一次尝试分析MP系统硬件实现。为了验证开发的软件,研究了两种不同的MP系统:静脉葡萄糖耐量试验(IVGTT)中葡萄糖-胰岛素相互作用模型,以及非光化学猝灭过程。检验了所实现系统的计算精度和硬件资源的使用情况。发现代码生成工具工作良好;然而,最终的决定必须由开发人员做出,因为有时必须考虑多个实现体系结构备选方案。作为典型的例子,IVGTT MP系统的21-23位FPGA实现在数字信号处理器(DSP)、切片和4输入LUT使用中体现了这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automated Metabolic P System Placement in FPGA
Abstract An original Very High Speed Integrated Circuit Hardware Description Language (VHDL) code generation tool that can be used to automate Metabolic P (MP) system implementation in hardware such as Field Programmable Gate Arrays (FPGA) is described. Unlike P systems, MP systems use a single membrane in their computations. Nevertheless, there are many biological processes that have been successfully modeled by MP systems in software. This is the first attempt to analyze MP system hardware implementations. Two different MP systems are investigated with the purpose of verifying the developed software: the model of glucose–insulin interactions in the Intravenous Glucose Tolerance Test (IVGTT), and the Non-Photochemical Quenching process. The implemented systems’ calculation accuracy and hardware resource usage are examined. It is found that code generation tool works adequately; however, a final decision has to be done by the developer because sometimes several implementation architecture alternatives have to be considered. As an archetypical example serves the IVGTT MP systems’ 21–23 bits FPGA implementation manifesting this in the Digital Signal Processor (DSP), slice, and 4-input LUT usage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electrical Control and Communication Engineering
Electrical Control and Communication Engineering ENGINEERING, ELECTRICAL & ELECTRONIC-
自引率
14.30%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信