D. González-Quevedo, Departamento de Cirugía Ortopédica y Traumatología, Javier Martínez-Malo, Guillermo Montesa, I. Tamimi, M. Bravo-Bardají, D. García-de-Quevedo
{"title":"股骨近端防旋转钉(PFNA)长度和术后并发症:一项回顾性队列研究","authors":"D. González-Quevedo, Departamento de Cirugía Ortopédica y Traumatología, Javier Martínez-Malo, Guillermo Montesa, I. Tamimi, M. Bravo-Bardají, D. García-de-Quevedo","doi":"10.15568/AM.2019.806.OR03","DOIUrl":null,"url":null,"abstract":"espanolObjetivos: Los clavos proximales de femur fueron disenados para realizar una cirugia minimamente invasiva y reducir la tasa de complicaciones en pacientes con fracturas de femur proximal. Planteamos la hipotesis que el tamano de estos clavos influye en las complicaciones postoperatorias. Material y Metodos: Realizamos un estudio de cohortes retrospectivas en pacientes con fracturas de femur proximal que fueron sintetizadas con un PFNA durante el periodo comprendido entre enero de 2012 y marzo de 2014. La siguiente informacion fue recogida de nuestra base de datos informatica: longitud del implante, duracion de la cirugia, hemoglobina postoperatoria, necesidad de transfusion, estancia hospitalaria, presencia de complicaciones y mortalidad. Los pacientes fueron seguidos durante un ano despues de la cirugia. Resultados: Un total de 400 pacientes fueron incluidos en este estudio. La edad media de los pacientes fue de 80.45 ± 0.53 anos; 98 (24.5%) pacientes fallecieron durante el periodo de seguimiento. El tiempo quirurgico fue de 38.70±0.68, 50.31±1.88 y 66.92±3.44 minutos, para los pacientes con clavos de 170, 200 y 240 mm respectivamente (P0.05). La diferencia de hemoglobina pre y postoperatoria fue menor en pacientes intervenidos con clavos de 170 mm comparado con 200 y 240 mm [2.43±0.08 g/dl; 2.81±0.16 g/dl; y 2.50±0.06 g/dl, respectivamente (P0.01)]. Comparado con los clavos de 170 mm, las odd ratios para la necesidad de transfusion fueron 2.83 (1.57-5.10) paa clavos de 200 mm, y 2.58 (1.26-5.30) para clavos de 240 mm. La longitud del clavo no afecto a la estancia hospitalaria, presencia de cut-out y la tasa de mortalidad. Conclusiones: El uso de clavos proximales mas largos esta asociado con un incremento de la duracion de la cirugia, menos niveles de hemoglobina postoperatorios y mayores tasas de transfusion. La longitud del implante no influye en las tasas de cut-out y mortalidad. EnglishObjectives: Proximal femoral nails were developed to perform minimally invasive surgery and reduce the complication rates in patients with proximal femoral fractures. We hypothesize that the length of these nails may influence the surgical outcome. Methods: We conducted a retrospective cohort study on patients with proximal femoral fractures who were treated with a PFNA during the period between January 2012 and March 2014. The following information was withdrawn from our local computerized database: nail length, duration of surgery, postoperative hemoglobin level, transfusion requirements, hospital stay, presence of surgical complications and mortality. Patients were followed for one year after surgery. Results: A total of 400 cases were included in this study. The mean age was 80.45 ± 0.53 years; 98 (24.5%) patients died during the follow-up period (one year). The surgical time was 38.70±0.68, 50.31±1.88 and 66.92±3.44 min, for patients with 170, 200, and 240 mm nails, respectively (P0.05). The change in the preoperative to postoperative hemoglobin levels was lower in patients operated with 170 nails compared to 200 and 240 nails [2.43±0.08 g/dl; 2.81±0.16 g/dl; and 2.50±0.06 g/dl, respectively (P0.01)]. Compared to 170 nails the odd ratios for postoperativ transfusions were 2.83 (1.57-5.10) for 200 nails, and 2.58 (1.26-5.30) for 240 nails. The nail length did not affect hospital stay, presence of cut-out, or mrtality rate. Conclusions: The use of longer proximal nails is associated with increased surgical duration, lower postoperative hemoglobin levels and higher transfusion rates. The implant length did not influence the cut-out or mortality rates.","PeriodicalId":86333,"journal":{"name":"Actualidad medica","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proximal Femoral Nail Antirotation (PFNA) length and postoperative complications: a retrospective cohort study\",\"authors\":\"D. González-Quevedo, Departamento de Cirugía Ortopédica y Traumatología, Javier Martínez-Malo, Guillermo Montesa, I. Tamimi, M. Bravo-Bardají, D. García-de-Quevedo\",\"doi\":\"10.15568/AM.2019.806.OR03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"espanolObjetivos: Los clavos proximales de femur fueron disenados para realizar una cirugia minimamente invasiva y reducir la tasa de complicaciones en pacientes con fracturas de femur proximal. Planteamos la hipotesis que el tamano de estos clavos influye en las complicaciones postoperatorias. Material y Metodos: Realizamos un estudio de cohortes retrospectivas en pacientes con fracturas de femur proximal que fueron sintetizadas con un PFNA durante el periodo comprendido entre enero de 2012 y marzo de 2014. La siguiente informacion fue recogida de nuestra base de datos informatica: longitud del implante, duracion de la cirugia, hemoglobina postoperatoria, necesidad de transfusion, estancia hospitalaria, presencia de complicaciones y mortalidad. Los pacientes fueron seguidos durante un ano despues de la cirugia. Resultados: Un total de 400 pacientes fueron incluidos en este estudio. La edad media de los pacientes fue de 80.45 ± 0.53 anos; 98 (24.5%) pacientes fallecieron durante el periodo de seguimiento. El tiempo quirurgico fue de 38.70±0.68, 50.31±1.88 y 66.92±3.44 minutos, para los pacientes con clavos de 170, 200 y 240 mm respectivamente (P0.05). La diferencia de hemoglobina pre y postoperatoria fue menor en pacientes intervenidos con clavos de 170 mm comparado con 200 y 240 mm [2.43±0.08 g/dl; 2.81±0.16 g/dl; y 2.50±0.06 g/dl, respectivamente (P0.01)]. Comparado con los clavos de 170 mm, las odd ratios para la necesidad de transfusion fueron 2.83 (1.57-5.10) paa clavos de 200 mm, y 2.58 (1.26-5.30) para clavos de 240 mm. La longitud del clavo no afecto a la estancia hospitalaria, presencia de cut-out y la tasa de mortalidad. Conclusiones: El uso de clavos proximales mas largos esta asociado con un incremento de la duracion de la cirugia, menos niveles de hemoglobina postoperatorios y mayores tasas de transfusion. La longitud del implante no influye en las tasas de cut-out y mortalidad. EnglishObjectives: Proximal femoral nails were developed to perform minimally invasive surgery and reduce the complication rates in patients with proximal femoral fractures. We hypothesize that the length of these nails may influence the surgical outcome. Methods: We conducted a retrospective cohort study on patients with proximal femoral fractures who were treated with a PFNA during the period between January 2012 and March 2014. The following information was withdrawn from our local computerized database: nail length, duration of surgery, postoperative hemoglobin level, transfusion requirements, hospital stay, presence of surgical complications and mortality. Patients were followed for one year after surgery. Results: A total of 400 cases were included in this study. The mean age was 80.45 ± 0.53 years; 98 (24.5%) patients died during the follow-up period (one year). The surgical time was 38.70±0.68, 50.31±1.88 and 66.92±3.44 min, for patients with 170, 200, and 240 mm nails, respectively (P0.05). The change in the preoperative to postoperative hemoglobin levels was lower in patients operated with 170 nails compared to 200 and 240 nails [2.43±0.08 g/dl; 2.81±0.16 g/dl; and 2.50±0.06 g/dl, respectively (P0.01)]. Compared to 170 nails the odd ratios for postoperativ transfusions were 2.83 (1.57-5.10) for 200 nails, and 2.58 (1.26-5.30) for 240 nails. The nail length did not affect hospital stay, presence of cut-out, or mrtality rate. Conclusions: The use of longer proximal nails is associated with increased surgical duration, lower postoperative hemoglobin levels and higher transfusion rates. The implant length did not influence the cut-out or mortality rates.\",\"PeriodicalId\":86333,\"journal\":{\"name\":\"Actualidad medica\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Actualidad medica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15568/AM.2019.806.OR03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Actualidad medica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15568/AM.2019.806.OR03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的:设计股骨近端钉进行微创手术,降低股骨近端骨折患者的并发症率。我们假设这些指甲的大小对术后并发症有影响。材料和方法:我们对2012年1月至2014年3月用PFNA合成的股骨近端骨折患者进行了回顾性队列研究。从我们的informatica数据库中收集了以下信息:植入长度、手术时间、术后血红蛋白、输血需求、住院时间、是否存在并发症和死亡率。患者在手术后随访一年。结果:本研究共纳入400例患者。患者平均年龄80.45±0.53岁;98例(24.5%)患者在随访期间死亡。手术时间分别为38.70±0.68、50.31±1.88、66.92±3.44 min (P0.05)。与200和240 mm指甲相比,170 mm指甲干预患者术前和术后血红蛋白差异较小[2.43±0.08 g/dl;2.81±0.16 g / dl;分别为2.50±0.06 g/dl (P0.01)]。与170 mm钉子相比,200 mm钉子需要输血的odd比为2.83 (1.57-5.10),240 mm钉子需要输血的odd比为2.58(1.26-5.30)。我们的目的是评估指甲长度对住院时间、是否有切割和死亡率的影响。近端钉的使用与手术时间的增加、术后血红蛋白水平的降低和输血率的增加有关。种植体的长度不影响切割率和死亡率。目的:开发近端股钉用于进行微创手术,降低近端股骨折患者的并发症率。We hypothesize that the length of nails可能影响这些数额surgical的结果。方法:我们对2012年1月至2014年3月接受PFNA治疗的近端股骨折患者进行了回顾性队列研究。以下信息来自我们当地的计算机化数据库:指甲长度、手术时间、术后血红蛋白水平、输血需求、住院时间、是否存在手术并发症和死亡率。患者术后随访一年。结果:本研究共纳入400例病例。平均年龄为80.45±0.53岁;98例(24.5%)患者在随访期间(1年)死亡。170、200和240 mm钉患者的手术时间分别为38.70±0.68、50.31±1.88和66.92±3.44 min (P0.05)。与200和240钉相比,170钉手术患者术前至术后血红蛋白水平变化较低[2.43±0.08 g/dl;2.81±0.16 g / dl;分别为2.50±0.06 g/dl (P0.01)]。与170钉相比,200钉术后输血的奇数比为2.83(1.57-5.10),240钉术后输血的奇数比为2.58(1.26-5.30)。= =地理= =根据美国人口普查,这个县的总面积为,其中土地和(0.9%)水。结论:使用较长的近端钉与增加手术时间、降低术后血红蛋白水平和较高的输血率有关。= =地理= =根据美国人口普查,该地区的总面积为,其中土地和(1.2%)水。
Proximal Femoral Nail Antirotation (PFNA) length and postoperative complications: a retrospective cohort study
espanolObjetivos: Los clavos proximales de femur fueron disenados para realizar una cirugia minimamente invasiva y reducir la tasa de complicaciones en pacientes con fracturas de femur proximal. Planteamos la hipotesis que el tamano de estos clavos influye en las complicaciones postoperatorias. Material y Metodos: Realizamos un estudio de cohortes retrospectivas en pacientes con fracturas de femur proximal que fueron sintetizadas con un PFNA durante el periodo comprendido entre enero de 2012 y marzo de 2014. La siguiente informacion fue recogida de nuestra base de datos informatica: longitud del implante, duracion de la cirugia, hemoglobina postoperatoria, necesidad de transfusion, estancia hospitalaria, presencia de complicaciones y mortalidad. Los pacientes fueron seguidos durante un ano despues de la cirugia. Resultados: Un total de 400 pacientes fueron incluidos en este estudio. La edad media de los pacientes fue de 80.45 ± 0.53 anos; 98 (24.5%) pacientes fallecieron durante el periodo de seguimiento. El tiempo quirurgico fue de 38.70±0.68, 50.31±1.88 y 66.92±3.44 minutos, para los pacientes con clavos de 170, 200 y 240 mm respectivamente (P0.05). La diferencia de hemoglobina pre y postoperatoria fue menor en pacientes intervenidos con clavos de 170 mm comparado con 200 y 240 mm [2.43±0.08 g/dl; 2.81±0.16 g/dl; y 2.50±0.06 g/dl, respectivamente (P0.01)]. Comparado con los clavos de 170 mm, las odd ratios para la necesidad de transfusion fueron 2.83 (1.57-5.10) paa clavos de 200 mm, y 2.58 (1.26-5.30) para clavos de 240 mm. La longitud del clavo no afecto a la estancia hospitalaria, presencia de cut-out y la tasa de mortalidad. Conclusiones: El uso de clavos proximales mas largos esta asociado con un incremento de la duracion de la cirugia, menos niveles de hemoglobina postoperatorios y mayores tasas de transfusion. La longitud del implante no influye en las tasas de cut-out y mortalidad. EnglishObjectives: Proximal femoral nails were developed to perform minimally invasive surgery and reduce the complication rates in patients with proximal femoral fractures. We hypothesize that the length of these nails may influence the surgical outcome. Methods: We conducted a retrospective cohort study on patients with proximal femoral fractures who were treated with a PFNA during the period between January 2012 and March 2014. The following information was withdrawn from our local computerized database: nail length, duration of surgery, postoperative hemoglobin level, transfusion requirements, hospital stay, presence of surgical complications and mortality. Patients were followed for one year after surgery. Results: A total of 400 cases were included in this study. The mean age was 80.45 ± 0.53 years; 98 (24.5%) patients died during the follow-up period (one year). The surgical time was 38.70±0.68, 50.31±1.88 and 66.92±3.44 min, for patients with 170, 200, and 240 mm nails, respectively (P0.05). The change in the preoperative to postoperative hemoglobin levels was lower in patients operated with 170 nails compared to 200 and 240 nails [2.43±0.08 g/dl; 2.81±0.16 g/dl; and 2.50±0.06 g/dl, respectively (P0.01)]. Compared to 170 nails the odd ratios for postoperativ transfusions were 2.83 (1.57-5.10) for 200 nails, and 2.58 (1.26-5.30) for 240 nails. The nail length did not affect hospital stay, presence of cut-out, or mrtality rate. Conclusions: The use of longer proximal nails is associated with increased surgical duration, lower postoperative hemoglobin levels and higher transfusion rates. The implant length did not influence the cut-out or mortality rates.