提高辐射发射测量实验室间比较(ILC)性能的重要性

Kye Yak, P. Sudhakar, D. Kumar, S. Baisakhiya, K. G. Thomas
{"title":"提高辐射发射测量实验室间比较(ILC)性能的重要性","authors":"Kye Yak, P. Sudhakar, D. Kumar, S. Baisakhiya, K. G. Thomas","doi":"10.1109/MEMC.2022.10058830","DOIUrl":null,"url":null,"abstract":"The key factors that influence the Radiated Emission (RE) measurement results of Inter Laboratory Comparison (ILC) program, conducted as part of proficiency testing/Quality Assurance of EMC test laboratory are presented in this paper. The evaluated classical Z score results and overall performance of the participant EMC test laboratories in ILC program are affected by these factors. The performance improvement techniques to address the influencing factors and eliminate the deviation in test results of ILC program are outlined in detail. A case study was conducted in the frequency range from 30 MHz to 1 GHz, as the deviation in Z score results is predominant below 1 GHz. The importance of awareness required to conduct ILC program accurately with minimum possible errors is highlighted in this paper.","PeriodicalId":73281,"journal":{"name":"IEEE electromagnetic compatibility magazine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Importance of Performance Improvement for Inter Laboratory Comparison (ILC) of Radiated Emission Measurements\",\"authors\":\"Kye Yak, P. Sudhakar, D. Kumar, S. Baisakhiya, K. G. Thomas\",\"doi\":\"10.1109/MEMC.2022.10058830\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The key factors that influence the Radiated Emission (RE) measurement results of Inter Laboratory Comparison (ILC) program, conducted as part of proficiency testing/Quality Assurance of EMC test laboratory are presented in this paper. The evaluated classical Z score results and overall performance of the participant EMC test laboratories in ILC program are affected by these factors. The performance improvement techniques to address the influencing factors and eliminate the deviation in test results of ILC program are outlined in detail. A case study was conducted in the frequency range from 30 MHz to 1 GHz, as the deviation in Z score results is predominant below 1 GHz. The importance of awareness required to conduct ILC program accurately with minimum possible errors is highlighted in this paper.\",\"PeriodicalId\":73281,\"journal\":{\"name\":\"IEEE electromagnetic compatibility magazine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE electromagnetic compatibility magazine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMC.2022.10058830\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE electromagnetic compatibility magazine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMC.2022.10058830","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了影响实验室间比较(ILC)项目辐射发射(RE)测量结果的关键因素,该项目是EMC测试实验室能力测试/质量保证的一部分。这些因素会影响ILC项目中参与EMC测试实验室的评估经典Z分数结果和整体性能。详细介绍了解决ILC程序测试结果偏差影响因素的性能改进技术。在30 MHz至1 GHz的频率范围内进行了案例研究,因为Z分数结果的偏差在1 GHz以下占主导地位。本文强调了以最小可能的错误准确地进行ILC程序所需的意识的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Importance of Performance Improvement for Inter Laboratory Comparison (ILC) of Radiated Emission Measurements
The key factors that influence the Radiated Emission (RE) measurement results of Inter Laboratory Comparison (ILC) program, conducted as part of proficiency testing/Quality Assurance of EMC test laboratory are presented in this paper. The evaluated classical Z score results and overall performance of the participant EMC test laboratories in ILC program are affected by these factors. The performance improvement techniques to address the influencing factors and eliminate the deviation in test results of ILC program are outlined in detail. A case study was conducted in the frequency range from 30 MHz to 1 GHz, as the deviation in Z score results is predominant below 1 GHz. The importance of awareness required to conduct ILC program accurately with minimum possible errors is highlighted in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信