Bahare Makvandi, Anton Pohanka, Mats Bergström, Annica Börjesson, Mikael Lehtihet, Lena Ekström, Yufang Zheng
{"title":"血清样品中合成代谢雄激素的检测","authors":"Bahare Makvandi, Anton Pohanka, Mats Bergström, Annica Börjesson, Mikael Lehtihet, Lena Ekström, Yufang Zheng","doi":"10.1002/dta.3476","DOIUrl":null,"url":null,"abstract":"<p>When testing for anabolic androgenic steroids (AAS) outside sports communities, for example, in healthcare and forensic medicine, urine is the matrix of choice. However, there are drawbacks with urinary sampling, and serum might be useful as a complementary matrix. The aim was to develop an LC–MS/MS method for serum measuring AAS frequently used outside of sport, including testosterone (T), steroid esters, and eight other synthetic AAS. The sample pretreatment included sample precipitation and evaporation. Limit of quantification for the AAS was 0.05–0.5 ng/mL, and linearity was 0.05–20 ng/mL for most of the substances. Generally, the within- and between-day CV results, matrix effect, and process efficiency were <15%. The AAS were stable for at least 6 months at −20°C. Serum samples were obtained from previous studies. A novel finding from an administration study was that T enanthate was present in serum even after 5 years of storage at −20°C. Serum samples from self-reporting AAS individuals, where T esters were detected, were positive for testosterone using the urinary testosterone/epitestosterone criterion >10. Of those identified as positive in traditional urinary doping tests (<i>n</i> = 15), AAS in serum were found in 80% of the subjects. Our results show that serum may be a valid complementary matrix to urine samples for AAS testing.</p>","PeriodicalId":160,"journal":{"name":"Drug Testing and Analysis","volume":"15 6","pages":"678-688"},"PeriodicalIF":2.6000,"publicationDate":"2023-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/dta.3476","citationCount":"2","resultStr":"{\"title\":\"Detection of anabolic androgenic steroids in serum samples\",\"authors\":\"Bahare Makvandi, Anton Pohanka, Mats Bergström, Annica Börjesson, Mikael Lehtihet, Lena Ekström, Yufang Zheng\",\"doi\":\"10.1002/dta.3476\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>When testing for anabolic androgenic steroids (AAS) outside sports communities, for example, in healthcare and forensic medicine, urine is the matrix of choice. However, there are drawbacks with urinary sampling, and serum might be useful as a complementary matrix. The aim was to develop an LC–MS/MS method for serum measuring AAS frequently used outside of sport, including testosterone (T), steroid esters, and eight other synthetic AAS. The sample pretreatment included sample precipitation and evaporation. Limit of quantification for the AAS was 0.05–0.5 ng/mL, and linearity was 0.05–20 ng/mL for most of the substances. Generally, the within- and between-day CV results, matrix effect, and process efficiency were <15%. The AAS were stable for at least 6 months at −20°C. Serum samples were obtained from previous studies. A novel finding from an administration study was that T enanthate was present in serum even after 5 years of storage at −20°C. Serum samples from self-reporting AAS individuals, where T esters were detected, were positive for testosterone using the urinary testosterone/epitestosterone criterion >10. Of those identified as positive in traditional urinary doping tests (<i>n</i> = 15), AAS in serum were found in 80% of the subjects. Our results show that serum may be a valid complementary matrix to urine samples for AAS testing.</p>\",\"PeriodicalId\":160,\"journal\":{\"name\":\"Drug Testing and Analysis\",\"volume\":\"15 6\",\"pages\":\"678-688\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-03-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/dta.3476\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drug Testing and Analysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/dta.3476\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Testing and Analysis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/dta.3476","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Detection of anabolic androgenic steroids in serum samples
When testing for anabolic androgenic steroids (AAS) outside sports communities, for example, in healthcare and forensic medicine, urine is the matrix of choice. However, there are drawbacks with urinary sampling, and serum might be useful as a complementary matrix. The aim was to develop an LC–MS/MS method for serum measuring AAS frequently used outside of sport, including testosterone (T), steroid esters, and eight other synthetic AAS. The sample pretreatment included sample precipitation and evaporation. Limit of quantification for the AAS was 0.05–0.5 ng/mL, and linearity was 0.05–20 ng/mL for most of the substances. Generally, the within- and between-day CV results, matrix effect, and process efficiency were <15%. The AAS were stable for at least 6 months at −20°C. Serum samples were obtained from previous studies. A novel finding from an administration study was that T enanthate was present in serum even after 5 years of storage at −20°C. Serum samples from self-reporting AAS individuals, where T esters were detected, were positive for testosterone using the urinary testosterone/epitestosterone criterion >10. Of those identified as positive in traditional urinary doping tests (n = 15), AAS in serum were found in 80% of the subjects. Our results show that serum may be a valid complementary matrix to urine samples for AAS testing.
期刊介绍:
As the incidence of drugs escalates in 21st century living, their detection and analysis have become increasingly important. Sport, the workplace, crime investigation, homeland security, the pharmaceutical industry and the environment are just some of the high profile arenas in which analytical testing has provided an important investigative tool for uncovering the presence of extraneous substances.
In addition to the usual publishing fare of primary research articles, case reports and letters, Drug Testing and Analysis offers a unique combination of; ‘How to’ material such as ‘Tutorials’ and ‘Reviews’, Speculative pieces (‘Commentaries’ and ‘Perspectives'', providing a broader scientific and social context to the aspects of analytical testing), ‘Annual banned substance reviews’ (delivering a critical evaluation of the methods used in the characterization of established and newly outlawed compounds).
Rather than focus on the application of a single technique, Drug Testing and Analysis employs a unique multidisciplinary approach to the field of controversial compound determination. Papers discussing chromatography, mass spectrometry, immunological approaches, 1D/2D gel electrophoresis, to name just a few select methods, are welcomed where their application is related to any of the six key topics listed below.