量化加拿大泰晤士河的磷负荷

Q1 Environmental Science
Tony Van Rossum , Yaghoub (Jacobe) Norouzi
{"title":"量化加拿大泰晤士河的磷负荷","authors":"Tony Van Rossum ,&nbsp;Yaghoub (Jacobe) Norouzi","doi":"10.1016/j.watcyc.2021.06.002","DOIUrl":null,"url":null,"abstract":"<div><p>The Canada Ontario agreement requires reduction of total phosphorous (TP) loadings to prevent algae blooms in Lake Erie. This study was to consider TP loadings from the Thames River and potential methods needed to determine actual loadings. The study found TP loading in the Thames River was dominated by peak flow events and between 10 and 15% of the flow had over 60% of the loading. Identification of TP and Dissolved Reactive Phosphate (DRG) and/or Ortho phosphorous (Ortho P) have similar ratios with TP in the Thames River although are not the same in the main, north and south branches. Continuous ortho P monitoring equipment could be used to estimate TP loads based on ratios of Ortho P to TP established in the river shed. A description and cost estimate for a continuous monitoring system is included in the study. Reduction of TP loadings requires methods that can deal with the peak flows and one option could be wetlands along the river basin.</p></div>","PeriodicalId":34143,"journal":{"name":"Water Cycle","volume":"2 ","pages":"Pages 44-50"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.watcyc.2021.06.002","citationCount":"2","resultStr":"{\"title\":\"Quantifying phosphorous loadings in the Thames River in Canada\",\"authors\":\"Tony Van Rossum ,&nbsp;Yaghoub (Jacobe) Norouzi\",\"doi\":\"10.1016/j.watcyc.2021.06.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The Canada Ontario agreement requires reduction of total phosphorous (TP) loadings to prevent algae blooms in Lake Erie. This study was to consider TP loadings from the Thames River and potential methods needed to determine actual loadings. The study found TP loading in the Thames River was dominated by peak flow events and between 10 and 15% of the flow had over 60% of the loading. Identification of TP and Dissolved Reactive Phosphate (DRG) and/or Ortho phosphorous (Ortho P) have similar ratios with TP in the Thames River although are not the same in the main, north and south branches. Continuous ortho P monitoring equipment could be used to estimate TP loads based on ratios of Ortho P to TP established in the river shed. A description and cost estimate for a continuous monitoring system is included in the study. Reduction of TP loadings requires methods that can deal with the peak flows and one option could be wetlands along the river basin.</p></div>\",\"PeriodicalId\":34143,\"journal\":{\"name\":\"Water Cycle\",\"volume\":\"2 \",\"pages\":\"Pages 44-50\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.watcyc.2021.06.002\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Cycle\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666445321000040\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Cycle","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666445321000040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 2

摘要

加拿大安大略省协议要求减少总磷(TP)负荷,以防止伊利湖的藻类繁殖。本研究将考虑来自泰晤士河的TP负荷和确定实际负荷所需的潜在方法。研究发现,泰晤士河的TP负荷主要由峰值流量事件决定,10%到15%的流量超过了60%的负荷。TP和溶解活性磷酸盐(DRG)和/或邻磷(Ortho P)的鉴定在泰晤士河中与TP的比例相似,但在主、北、南分支中不相同。利用连续的正交磷监测设备,可以根据在河棚中建立的正交磷与总磷的比值来估计TP负荷。研究中包括对连续监测系统的描述和成本估算。减少总磷负荷需要能够处理峰值流量的方法,其中一个选择可能是沿流域的湿地。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantifying phosphorous loadings in the Thames River in Canada

The Canada Ontario agreement requires reduction of total phosphorous (TP) loadings to prevent algae blooms in Lake Erie. This study was to consider TP loadings from the Thames River and potential methods needed to determine actual loadings. The study found TP loading in the Thames River was dominated by peak flow events and between 10 and 15% of the flow had over 60% of the loading. Identification of TP and Dissolved Reactive Phosphate (DRG) and/or Ortho phosphorous (Ortho P) have similar ratios with TP in the Thames River although are not the same in the main, north and south branches. Continuous ortho P monitoring equipment could be used to estimate TP loads based on ratios of Ortho P to TP established in the river shed. A description and cost estimate for a continuous monitoring system is included in the study. Reduction of TP loadings requires methods that can deal with the peak flows and one option could be wetlands along the river basin.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Water Cycle
Water Cycle Engineering-Engineering (miscellaneous)
CiteScore
9.20
自引率
0.00%
发文量
20
审稿时长
45 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信